DAVID PERREAULT: OK, why
don't we get started?

00:00:13.310 --> 00:00:16.490 align:middle line:84%
So last class, we
talked about some things

00:00:16.490 --> 00:00:19.910 align:middle line:84%
that happened with
rectifier, on the DC side.

00:00:19.910 --> 00:00:23.330 align:middle line:84%
Today, I'd like to talk
about some measures

00:00:23.330 --> 00:00:26.450 align:middle line:84%
that we use when we're looking
at the AC side, so for example,

00:00:26.450 --> 00:00:29.040 align:middle line:84%
if I had a rectifier
connected to the grid.

00:00:29.040 --> 00:00:30.800 align:middle line:84%
But what we're going
to talk about applies

00:00:30.800 --> 00:00:34.670 align:middle line:84%
to all kinds of energy
transfers mediated

00:00:34.670 --> 00:00:37.670 align:middle line:90%
by time varying waveforms.

00:00:37.670 --> 00:00:39.410 align:middle line:84%
Before I get into
it, however, I just

00:00:39.410 --> 00:00:42.170 align:middle line:84%
wanted to remind you
of a few definitions

00:00:42.170 --> 00:00:45.080 align:middle line:84%
because we'll come
back and use them.

00:00:45.080 --> 00:00:49.190 align:middle line:84%
And the first of these is
simply the RMS, or the Root Mean

00:00:49.190 --> 00:00:59.120 align:middle line:90%
Square, of a signal.

00:00:59.120 --> 00:01:03.830 align:middle line:84%
So if I have a signal
x of t, the root

00:01:03.830 --> 00:01:14.690 align:middle line:84%
mean square is the square root
of the mean of x squared of t.

00:01:14.690 --> 00:01:16.683 align:middle line:90%
And I'd call that x RMS.

00:01:16.683 --> 00:01:20.090 align:middle line:90%


00:01:20.090 --> 00:01:21.740 align:middle line:84%
So there's a variety
of reasons why

00:01:21.740 --> 00:01:24.650 align:middle line:84%
you might want to calculate
the RMS of a signal.

00:01:24.650 --> 00:01:29.670 align:middle line:84%
But it's particularly useful
in thinking about energy.

00:01:29.670 --> 00:01:30.320 align:middle line:90%
Why?

00:01:30.320 --> 00:01:34.940 align:middle line:84%
Because suppose I had, for
example, a current waveform, i

00:01:34.940 --> 00:01:39.980 align:middle line:90%
of t, into a resistor.

00:01:39.980 --> 00:01:43.880 align:middle line:84%
And I said, how much
power is being transferred

00:01:43.880 --> 00:01:47.150 align:middle line:90%
into that resistor on average?

00:01:47.150 --> 00:01:53.330 align:middle line:84%
Well, p of t is
simply equal to v

00:01:53.330 --> 00:02:02.610 align:middle line:84%
times i, which would be equal
to i of t squared times R.

00:02:02.610 --> 00:02:07.220 align:middle line:84%
And then if I wanted
the average power,

00:02:07.220 --> 00:02:14.910 align:middle line:84%
I would calculate that as 1
over T, the integral over t of i

00:02:14.910 --> 00:02:22.290 align:middle line:84%
squared of t dt times R.
So I can take out the R.

00:02:22.290 --> 00:02:28.230 align:middle line:84%
And this gives me i
RMS squared times R.

00:02:28.230 --> 00:02:31.980 align:middle line:84%
So calculating the
RMS of a current

00:02:31.980 --> 00:02:36.570 align:middle line:84%
means it's the DC quantity--
it's the fixed quantity-- that

00:02:36.570 --> 00:02:38.940 align:middle line:84%
will transfer the
same amount of power

00:02:38.940 --> 00:02:41.020 align:middle line:90%
into a resistor as a current.

00:02:41.020 --> 00:02:45.210 align:middle line:84%
Or I could have done this with
the voltage, if it's a resistor.

00:02:45.210 --> 00:02:49.630 align:middle line:84%
So I don't need to know
everything about the waveform.

00:02:49.630 --> 00:02:53.040 align:middle line:84%
All I need to know is
this RMS, and i RMS

00:02:53.040 --> 00:02:56.850 align:middle line:84%
squared times R or v
RMS squared divided by R

00:02:56.850 --> 00:02:59.790 align:middle line:84%
gives me the power
dissipation or resistor.

00:02:59.790 --> 00:03:01.560 align:middle line:84%
Now if I don't
have joule heating,

00:03:01.560 --> 00:03:04.890 align:middle line:84%
if I don't have resistive
loss, maybe the RMS

00:03:04.890 --> 00:03:05.940 align:middle line:90%
isn't the right quantity.

00:03:05.940 --> 00:03:07.390 align:middle line:90%
But very often it is.

00:03:07.390 --> 00:03:12.260 align:middle line:84%
So that's why we tend
to care about it.

00:03:12.260 --> 00:03:16.220 align:middle line:84%
The second thing-- first of all,
any questions about the meaning

00:03:16.220 --> 00:03:17.875 align:middle line:90%
or use of root mean square?

00:03:17.875 --> 00:03:20.470 align:middle line:90%


00:03:20.470 --> 00:03:23.140 align:middle line:84%
The second thing I'd
like to remind you of

00:03:23.140 --> 00:03:26.395 align:middle line:90%
is the notion of orthogonality.

00:03:26.395 --> 00:03:31.630 align:middle line:90%


00:03:31.630 --> 00:03:34.945 align:middle line:84%
Now, I think it's particularly
obvious what orthogonality means

00:03:34.945 --> 00:03:36.820 align:middle line:84%
when you have a pair of
vectors, that they're

00:03:36.820 --> 00:03:38.450 align:middle line:90%
perpendicular in some sense.

00:03:38.450 --> 00:03:41.630 align:middle line:84%
But what does it mean for
continuous time waveforms?

00:03:41.630 --> 00:03:46.840 align:middle line:84%
Well, two waveforms,
x of t and y of t,

00:03:46.840 --> 00:04:01.060 align:middle line:84%
are orthogonal on an
interval if the following--

00:04:01.060 --> 00:04:10.660 align:middle line:84%
the integral from a to b of x of
t times y of t dt is equal to 0.

00:04:10.660 --> 00:04:14.500 align:middle line:84%
This is the natural assumption
of the inner product

00:04:14.500 --> 00:04:18.880 align:middle line:84%
for discrete sets or vectors or
something onto continuous time

00:04:18.880 --> 00:04:20.149 align:middle line:90%
waveforms.

00:04:20.149 --> 00:04:23.832 align:middle line:84%
So if I take the product of
the two, x of t and y of t,

00:04:23.832 --> 00:04:26.165 align:middle line:84%
and I integrate them over the
interval I'm interested in

00:04:26.165 --> 00:04:29.330 align:middle line:84%
and I get 0, that means
they're orthogonal.

00:04:29.330 --> 00:04:32.630 align:middle line:84%
What that implies,
among many other things,

00:04:32.630 --> 00:04:40.280 align:middle line:84%
for example, is if I had some
element and I had a voltage.

00:04:40.280 --> 00:04:45.920 align:middle line:84%
Say the voltage was x of t
and the current was y of t.

00:04:45.920 --> 00:04:50.270 align:middle line:84%
That would suggest that
over that interval of time,

00:04:50.270 --> 00:04:53.120 align:middle line:84%
x of t and y of t would
conspire to deliver

00:04:53.120 --> 00:04:56.120 align:middle line:90%
0 energy into the element.

00:04:56.120 --> 00:04:59.240 align:middle line:84%
So we have a general
definition for orthogonality

00:04:59.240 --> 00:05:02.690 align:middle line:84%
and it has some implications
about voltages and currents

00:05:02.690 --> 00:05:05.270 align:middle line:90%
if I use it for that.

00:05:05.270 --> 00:05:08.630 align:middle line:90%
Just as a reminder--

00:05:08.630 --> 00:05:10.600 align:middle line:90%
come back to some trigonometry.

00:05:10.600 --> 00:05:20.720 align:middle line:84%
If I have the integral over 2
pi of sine of n omega t times

00:05:20.720 --> 00:05:26.540 align:middle line:84%
sine of m omega t
plus some angle, phi,

00:05:26.540 --> 00:05:35.960 align:middle line:84%
d omega t is equal to 0 if
n not equal to m, meaning

00:05:35.960 --> 00:05:39.620 align:middle line:84%
if I have two sinusoids
at different frequencies--

00:05:39.620 --> 00:05:43.230 align:middle line:84%
and here I'm thinking about
on some commensurate interval.

00:05:43.230 --> 00:05:46.910 align:middle line:90%
So n and m are just different.

00:05:46.910 --> 00:05:48.060 align:middle line:90%
They're orthogonal.

00:05:48.060 --> 00:05:49.880 align:middle line:84%
If I multiply sine
at one frequency

00:05:49.880 --> 00:05:53.870 align:middle line:84%
by cosine or sine of at another
frequency and I integrate them,

00:05:53.870 --> 00:05:56.940 align:middle line:84%
I'm going to get
0, as long as I'm

00:05:56.940 --> 00:06:00.000 align:middle line:90%
over a commensurate interval.

00:06:00.000 --> 00:06:04.950 align:middle line:84%
So sine at one frequency
is orthogonal to sine waves

00:06:04.950 --> 00:06:06.260 align:middle line:90%
at any other frequency.

00:06:06.260 --> 00:06:08.130 align:middle line:84%
And this is the
fundamental trick

00:06:08.130 --> 00:06:10.140 align:middle line:84%
that we use to develop
Fourier series.

00:06:10.140 --> 00:06:12.510 align:middle line:84%
That's how we extract
out Fourier coefficients,

00:06:12.510 --> 00:06:17.310 align:middle line:84%
is using the orthogonality
of different frequencies.

00:06:17.310 --> 00:06:20.670 align:middle line:84%
Another thing I'll
remind you of is simply

00:06:20.670 --> 00:06:26.310 align:middle line:84%
that if I have the integral
of 0 over 2 pi of sine

00:06:26.310 --> 00:06:35.460 align:middle line:84%
of omega t times cosine of
omega t d omega t, I will get 0.

00:06:35.460 --> 00:06:38.700 align:middle line:84%
So not only are sinusoids
at different frequencies

00:06:38.700 --> 00:06:41.760 align:middle line:84%
orthogonal, but sine is
orthogonal to cosine even

00:06:41.760 --> 00:06:43.750 align:middle line:90%
at the same frequency.

00:06:43.750 --> 00:06:47.180 align:middle line:84%
And that's just a
straightforward trig identity,

00:06:47.180 --> 00:06:48.450 align:middle line:90%
easy to prove.

00:06:48.450 --> 00:06:56.440 align:middle line:84%
In general, more generally, we
can write that the 1 over 2 pi,

00:06:56.440 --> 00:07:06.640 align:middle line:84%
the integral over 0 to 2 pi of
sine omega t times sine of omega

00:07:06.640 --> 00:07:17.620 align:middle line:84%
t plus some angle phi d omega
t is simply equal to 1/2 cosine

00:07:17.620 --> 00:07:18.850 align:middle line:90%
of phi.

00:07:18.850 --> 00:07:25.630 align:middle line:84%
So if phi is 90 degrees, that
becomes a cosine, and I get 0.

00:07:25.630 --> 00:07:28.600 align:middle line:84%
If phi is 0 and I
have sine squared,

00:07:28.600 --> 00:07:31.570 align:middle line:84%
this is really saying that the
average value of sine squared

00:07:31.570 --> 00:07:34.100 align:middle line:90%
over an interval is 1/2.

00:07:34.100 --> 00:07:37.510 align:middle line:84%
So this is just basic
trigonometry again,

00:07:37.510 --> 00:07:39.910 align:middle line:84%
but it's a handy
result to remember.

00:07:39.910 --> 00:07:43.510 align:middle line:84%
And we'll see why we
care about this shortly.

00:07:43.510 --> 00:07:44.870 align:middle line:90%
Any questions about that?

00:07:44.870 --> 00:07:50.884 align:middle line:90%


00:07:50.884 --> 00:07:53.920 align:middle line:90%
So we'll come back and use that.

00:07:53.920 --> 00:08:00.970 align:middle line:84%
But let's start to think
about AC waveforms.

00:08:00.970 --> 00:08:07.210 align:middle line:84%
And let's talk about plugging
something into the wall.

00:08:07.210 --> 00:08:08.890 align:middle line:90%
So here's my wall.

00:08:08.890 --> 00:08:10.525 align:middle line:90%
I have Vs sine omega t.

00:08:10.525 --> 00:08:17.660 align:middle line:90%


00:08:17.660 --> 00:08:20.590 align:middle line:84%
And if I go back to the
source, somewhere in there

00:08:20.590 --> 00:08:22.990 align:middle line:90%
I'll have a breaker or a fuse.

00:08:22.990 --> 00:08:25.330 align:middle line:84%
And then I'll have
some wall wiring,

00:08:25.330 --> 00:08:26.930 align:middle line:90%
hopefully very low resistance.

00:08:26.930 --> 00:08:29.170 align:middle line:90%
I'll call this R wire.

00:08:29.170 --> 00:08:33.039 align:middle line:84%
And then I'll come somewhere
eventually to my plug,

00:08:33.039 --> 00:08:36.174 align:middle line:90%
and I can plug something in.

00:08:36.174 --> 00:08:38.590 align:middle line:84%
And here's my load
resistor that I'm going

00:08:38.590 --> 00:08:45.550 align:middle line:90%
to plug into the wall, R sub L.

00:08:45.550 --> 00:08:49.300 align:middle line:84%
Maybe this is my space
heater to keep me nice

00:08:49.300 --> 00:08:54.020 align:middle line:84%
and toasty warm in the winter
because it's a little bit cold.

00:08:54.020 --> 00:08:58.010 align:middle line:84%
So I'm going to go plug
this into the wall.

00:08:58.010 --> 00:09:02.960 align:middle line:84%
First of all, just as
an aside, why do we

00:09:02.960 --> 00:09:04.940 align:middle line:90%
have this fuse or breaker here?

00:09:04.940 --> 00:09:06.235 align:middle line:90%
What's it designed to do?

00:09:06.235 --> 00:09:09.937 align:middle line:90%


00:09:09.937 --> 00:09:12.522 align:middle line:84%
AUDIENCE: To prevent
overcurrents.

00:09:12.522 --> 00:09:13.980 align:middle line:84%
DAVID PERREAULT:
Well, that's true.

00:09:13.980 --> 00:09:15.630 align:middle line:84%
But for what reason,
specifically?

00:09:15.630 --> 00:09:18.440 align:middle line:84%
What's it preventing
an overcurrent of?

00:09:18.440 --> 00:09:21.189 align:middle line:84%
AUDIENCE: That the source
is not spiked consistent.

00:09:21.189 --> 00:09:23.382 align:middle line:90%
And if it spikes, it'll break.

00:09:23.382 --> 00:09:24.590 align:middle line:90%
DAVID PERREAULT: That's true.

00:09:24.590 --> 00:09:27.500 align:middle line:84%
I think those are
exactly correct answers.

00:09:27.500 --> 00:09:30.800 align:middle line:84%
The thing I was actually looking
for is a little bit more subtle.

00:09:30.800 --> 00:09:34.840 align:middle line:84%
Why would the-- certainly
if the source goes crazy

00:09:34.840 --> 00:09:37.250 align:middle line:84%
and gets too big, we
would want it to pop out.

00:09:37.250 --> 00:09:39.190 align:middle line:84%
But what it's really
designed to protect--

00:09:39.190 --> 00:09:40.060 align:middle line:90%
AUDIENCE: Load.

00:09:40.060 --> 00:09:42.310 align:middle line:84%
DAVID PERREAULT: Actually,
that's a very good thought.

00:09:42.310 --> 00:09:45.225 align:middle line:84%
Actually, it turns out
not to be the load.

00:09:45.225 --> 00:09:46.600 align:middle line:84%
I mean, one thing
is if something

00:09:46.600 --> 00:09:48.142 align:middle line:84%
goes wrong with the
load and the load

00:09:48.142 --> 00:09:51.100 align:middle line:84%
draws too much current,
you don't really

00:09:51.100 --> 00:09:53.090 align:middle line:84%
rely on the breaker or
the fuse to protect it.

00:09:53.090 --> 00:09:56.800 align:middle line:90%
By then, this thing is toast.

00:09:56.800 --> 00:09:59.600 align:middle line:84%
What the breaker is
specifically designed to do--

00:09:59.600 --> 00:10:01.480 align:middle line:84%
I mean, if it's the
fuse in the equipment,

00:10:01.480 --> 00:10:03.605 align:middle line:84%
maybe it's trying to help
you prevent the equipment

00:10:03.605 --> 00:10:04.370 align:middle line:90%
from burning down.

00:10:04.370 --> 00:10:07.270 align:middle line:84%
But the breaker back in
your home or in the wall

00:10:07.270 --> 00:10:10.810 align:middle line:84%
is designed to protect
the wiring because you

00:10:10.810 --> 00:10:12.370 align:middle line:84%
could, in principle,
plug something

00:10:12.370 --> 00:10:16.090 align:middle line:84%
in that would be happy enough,
wouldn't die, but would

00:10:16.090 --> 00:10:17.480 align:middle line:90%
draw too much current.

00:10:17.480 --> 00:10:20.030 align:middle line:84%
And then what happens when
your wall wires overheat?

00:10:20.030 --> 00:10:22.720 align:middle line:84%
They start a fire and then
really bad things happen.

00:10:22.720 --> 00:10:25.040 align:middle line:84%
So the fuse of the
breaker is really

00:10:25.040 --> 00:10:28.990 align:middle line:84%
designed to make sure that
the wiring doesn't overheat.

00:10:28.990 --> 00:10:31.513 align:middle line:84%
You can't count on that helping
you protect your equipment.

00:10:31.513 --> 00:10:33.680 align:middle line:84%
Your equipment, you might
put your own fuse in there

00:10:33.680 --> 00:10:36.030 align:middle line:84%
to help you keep the
equipment from burning down.

00:10:36.030 --> 00:10:39.450 align:middle line:90%
But it's a good thought.

00:10:39.450 --> 00:10:41.090 align:middle line:90%
So it is to protect things.

00:10:41.090 --> 00:10:44.900 align:middle line:84%
But really, it's designed
to protect the wire.

00:10:44.900 --> 00:10:50.120 align:middle line:84%
Now, for most purposes,
we can usually

00:10:50.120 --> 00:10:53.330 align:middle line:90%
ignore the wire resistance.

00:10:53.330 --> 00:10:56.600 align:middle line:84%
So let's for the moment pretend
the wire resistance is 0

00:10:56.600 --> 00:10:59.000 align:middle line:84%
because if you're burning
lots of power in the wire,

00:10:59.000 --> 00:11:01.040 align:middle line:90%
you're probably unhappy anyways.

00:11:01.040 --> 00:11:04.170 align:middle line:84%
So we'll just ignore that
for our calculations.

00:11:04.170 --> 00:11:09.470 align:middle line:84%
So what is the power going
into my space heater here?

00:11:09.470 --> 00:11:12.320 align:middle line:90%
Well, P of t--

00:11:12.320 --> 00:11:14.880 align:middle line:90%
here is V sub L. Here is i.

00:11:14.880 --> 00:11:18.950 align:middle line:90%
So P of t would equal--

00:11:18.950 --> 00:11:20.540 align:middle line:84%
as we calculated,
it would just be

00:11:20.540 --> 00:11:27.660 align:middle line:84%
equal to i squared of t
times R, which would be--

00:11:27.660 --> 00:11:30.180 align:middle line:84%
if VL is approximately
equal to Vs

00:11:30.180 --> 00:11:32.850 align:middle line:84%
because I'm ignoring
the wiring resistance,

00:11:32.850 --> 00:11:34.270 align:middle line:90%
I could calculate it that way.

00:11:34.270 --> 00:11:36.770 align:middle line:84%
And I could say that
the average power--

00:11:36.770 --> 00:11:46.770 align:middle line:84%
I'll just call that P or PAv is
simply IRMS squared times RL.

00:11:46.770 --> 00:11:51.720 align:middle line:90%
So if, for example--

00:11:51.720 --> 00:11:58.830 align:middle line:90%
if VRMS is equal to 115 volts--

00:11:58.830 --> 00:12:02.700 align:middle line:84%
that means a peak sinusoid
more like 170 volts--

00:12:02.700 --> 00:12:16.650 align:middle line:84%
and the fuse or the breaker is
15 amps, now this plug here--

00:12:16.650 --> 00:12:19.590 align:middle line:90%
if you're two plugs--

00:12:19.590 --> 00:12:21.720 align:middle line:84%
you have a long one
and a short one--

00:12:21.720 --> 00:12:26.700 align:middle line:84%
if your plug looks like this,
that's a 15-amp circuit.

00:12:26.700 --> 00:12:30.270 align:middle line:84%
So it's intended that you're
plugging that back into a 15-amp

00:12:30.270 --> 00:12:30.910 align:middle line:90%
line.

00:12:30.910 --> 00:12:33.180 align:middle line:84%
If you looked at this
one in particular,

00:12:33.180 --> 00:12:37.560 align:middle line:84%
it actually has another sideways
pin that you could actually

00:12:37.560 --> 00:12:39.390 align:middle line:84%
plug something in up
to 20 amps, and you'd

00:12:39.390 --> 00:12:41.140 align:middle line:84%
have a slightly different
plug to do that.

00:12:41.140 --> 00:12:43.037 align:middle line:84%
And that means the wall
wiring in this case

00:12:43.037 --> 00:12:45.120 align:middle line:84%
is a little bit heftier
and can carry more current

00:12:45.120 --> 00:12:47.530 align:middle line:84%
and the breaker's
designed to carry that.

00:12:47.530 --> 00:12:49.530 align:middle line:90%
So this is by the by.

00:12:49.530 --> 00:12:52.920 align:middle line:84%
But suppose I had
a 115-volt RMS,

00:12:52.920 --> 00:12:56.730 align:middle line:84%
which is about what it's
supposed to be, and 15 amps.

00:12:56.730 --> 00:12:58.230 align:middle line:90%
That would give me--

00:12:58.230 --> 00:13:05.820 align:middle line:84%
if I plug this into here would
give me about 1.7 kilowatts.

00:13:05.820 --> 00:13:07.830 align:middle line:84%
So in fact, if you go to
the store and you look,

00:13:07.830 --> 00:13:10.260 align:middle line:84%
you'll see a lot of
space heaters rated

00:13:10.260 --> 00:13:13.398 align:middle line:84%
for just about 1.7 kilowatts
or a lot of things you're

00:13:13.398 --> 00:13:14.440 align:middle line:90%
going to plug in at home.

00:13:14.440 --> 00:13:14.640 align:middle line:90%
Why?

00:13:14.640 --> 00:13:16.515 align:middle line:84%
Because you can put them
on a 15-amp circuit,

00:13:16.515 --> 00:13:20.084 align:middle line:84%
and that's what a lot of
people have in their homes.

00:13:20.084 --> 00:13:23.020 align:middle line:90%
So all right, that's good.

00:13:23.020 --> 00:13:25.005 align:middle line:90%
I can stay nice and warm.

00:13:25.005 --> 00:13:28.150 align:middle line:90%


00:13:28.150 --> 00:13:30.500 align:middle line:84%
Suppose I wanted to plug
in a different load.

00:13:30.500 --> 00:13:35.440 align:middle line:84%
So suppose I come back,
and here's Vs sine omega t.

00:13:35.440 --> 00:13:38.330 align:middle line:90%


00:13:38.330 --> 00:13:41.160 align:middle line:90%
And here's my fuse and my wire.

00:13:41.160 --> 00:13:43.870 align:middle line:90%


00:13:43.870 --> 00:13:46.060 align:middle line:90%
And now I'll come and plug--

00:13:46.060 --> 00:13:51.940 align:middle line:84%
suppose I plug in an inductor
into the wall here, L.

00:13:51.940 --> 00:13:53.410 align:middle line:90%
It's not that cold these days.

00:13:53.410 --> 00:13:55.990 align:middle line:84%
Maybe I just want to,
while I'm working,

00:13:55.990 --> 00:13:59.210 align:middle line:84%
bathe in the luxuriant magnetic
fields from my inductor.

00:13:59.210 --> 00:14:02.950 align:middle line:84%
So I plug an inductor
into the wall.

00:14:02.950 --> 00:14:11.260 align:middle line:90%
Well, again, ignoring our wire--

00:14:11.260 --> 00:14:15.340 align:middle line:84%
so I'm assuming
that this voltage is

00:14:15.340 --> 00:14:19.000 align:middle line:90%
the same as the source voltage.

00:14:19.000 --> 00:14:20.220 align:middle line:90%
Then what would I get?

00:14:20.220 --> 00:14:25.970 align:middle line:84%
Well, I would get i
of t would be what?

00:14:25.970 --> 00:14:28.090 align:middle line:90%
Well, V is equal to Ldi/dt.

00:14:28.090 --> 00:14:36.540 align:middle line:84%
So this should be 1 over L, the
integral of Vs sine of omega t

00:14:36.540 --> 00:14:37.040 align:middle line:90%
dt.

00:14:37.040 --> 00:14:39.630 align:middle line:90%


00:14:39.630 --> 00:14:43.110 align:middle line:84%
Well, this should be
equal to minus V sub s

00:14:43.110 --> 00:14:47.030 align:middle line:90%
over omega L cosine of omega t.

00:14:47.030 --> 00:14:49.590 align:middle line:90%


00:14:49.590 --> 00:14:54.450 align:middle line:84%
All right, so that's what I
get for a result for my current

00:14:54.450 --> 00:14:57.990 align:middle line:84%
in steady state
into my inductor.

00:14:57.990 --> 00:15:00.990 align:middle line:84%
What is the power
that's being transferred

00:15:00.990 --> 00:15:03.740 align:middle line:90%
into the inductor on average?

00:15:03.740 --> 00:15:05.170 align:middle line:90%
Why don't we calculate that?

00:15:05.170 --> 00:15:13.720 align:middle line:84%
We said PAv is equal to
1 over 2 pi, the integral

00:15:13.720 --> 00:15:18.910 align:middle line:84%
from 0 to 2 pi of the
voltage, which is V sine omega

00:15:18.910 --> 00:15:33.240 align:middle line:84%
t, times the current minus Vs
over omega L cosine omega t d

00:15:33.240 --> 00:15:35.070 align:middle line:90%
omega t.

00:15:35.070 --> 00:15:40.680 align:middle line:84%
I just did my average in
angle instead of in time.

00:15:40.680 --> 00:15:42.900 align:middle line:84%
Well, what does
this work out to be?

00:15:42.900 --> 00:15:54.150 align:middle line:84%
Well, this is minus Vs
squared over 2 pi omega L

00:15:54.150 --> 00:16:00.710 align:middle line:84%
times the integral over 2 pi
of sine omega t cosine omega t.

00:16:00.710 --> 00:16:07.410 align:middle line:90%


00:16:07.410 --> 00:16:10.002 align:middle line:84%
Can anybody tell
me what that is?

00:16:10.002 --> 00:16:10.860 align:middle line:90%
AUDIENCE: 0.

00:16:10.860 --> 00:16:11.830 align:middle line:90%
DAVID PERREAULT: 0.

00:16:11.830 --> 00:16:13.240 align:middle line:90%
Why is it 0?

00:16:13.240 --> 00:16:17.890 align:middle line:84%
Because the voltage is a sine,
and the current is a cosine.

00:16:17.890 --> 00:16:23.410 align:middle line:84%
And we just decided that sines
and cosines were orthogonal.

00:16:23.410 --> 00:16:33.240 align:middle line:84%
So I'm going to draw no
average power into my inductor.

00:16:33.240 --> 00:16:37.610 align:middle line:84%
That kind of makes sense
because the inductor is ideally

00:16:37.610 --> 00:16:38.980 align:middle line:90%
a lossless element.

00:16:38.980 --> 00:16:42.660 align:middle line:84%
So it shouldn't be able
to absorb average power.

00:16:42.660 --> 00:16:46.760 align:middle line:84%
What I am doing, however, I'm
not absorbing power on average,

00:16:46.760 --> 00:16:48.963 align:middle line:90%
but I do have current.

00:16:48.963 --> 00:16:50.630 align:middle line:84%
There's current going
into the inductor,

00:16:50.630 --> 00:16:52.130 align:middle line:84%
and there's voltage
on the inductor.

00:16:52.130 --> 00:16:54.830 align:middle line:84%
So I do have some energy
transfer instantaneously.

00:16:54.830 --> 00:16:59.505 align:middle line:84%
Or what I have is slosh
of energy from the wall

00:16:59.505 --> 00:17:01.130 align:middle line:84%
into the inductor
and from the inductor

00:17:01.130 --> 00:17:05.569 align:middle line:84%
back into the wall but
no loss as long as long

00:17:05.569 --> 00:17:08.990 align:middle line:90%
as I can ignore our wire.

00:17:08.990 --> 00:17:12.260 align:middle line:84%
That's what's known as
reactive power transfer

00:17:12.260 --> 00:17:17.314 align:middle line:84%
because it's a
reactive component.

00:17:17.314 --> 00:17:20.030 align:middle line:90%
So that makes sense.

00:17:20.030 --> 00:17:24.650 align:middle line:84%
But notice that while I'm
drawing no average power,

00:17:24.650 --> 00:17:27.540 align:middle line:90%
I still have current.

00:17:27.540 --> 00:17:31.650 align:middle line:90%
And that means I am still--

00:17:31.650 --> 00:17:33.960 align:middle line:84%
I have some current
here, so I am still

00:17:33.960 --> 00:17:37.950 align:middle line:84%
dissipating some energy
in that wiring resistance.

00:17:37.950 --> 00:17:41.490 align:middle line:84%
And I'm still limited
in the current

00:17:41.490 --> 00:17:45.420 align:middle line:84%
I can draw before
the breaker goes

00:17:45.420 --> 00:17:47.610 align:middle line:84%
or before the fuse pops
because the fuse is

00:17:47.610 --> 00:17:49.710 align:middle line:90%
designed to essentially pop--

00:17:49.710 --> 00:17:53.910 align:middle line:84%
or the breaker is designed to
pop based on a long-term RMS

00:17:53.910 --> 00:17:55.050 align:middle line:90%
current.

00:17:55.050 --> 00:17:57.070 align:middle line:90%
So what does that look like?

00:17:57.070 --> 00:17:59.250 align:middle line:84%
Well, if I could figure
out the RMS current,

00:17:59.250 --> 00:18:04.483 align:middle line:84%
IRMS here is equal to the
peak value-- it's a sinusoid.

00:18:04.483 --> 00:18:06.400 align:middle line:84%
It's the peak value over
the square root of 2.

00:18:06.400 --> 00:18:12.320 align:middle line:84%
So it would be Vs over the
square root of 2 omega L.

00:18:12.320 --> 00:18:20.780 align:middle line:84%
So if I again have omega is
equal to 377 radians per second

00:18:20.780 --> 00:18:25.310 align:middle line:84%
in the United States-- that's
60 hertz, essentially--

00:18:25.310 --> 00:18:36.740 align:middle line:84%
L of about 20 millihenries
gives IRMS of about 15 amps

00:18:36.740 --> 00:18:38.810 align:middle line:90%
at 115 volts AC.

00:18:38.810 --> 00:18:45.110 align:middle line:90%


00:18:45.110 --> 00:18:46.190 align:middle line:90%
So what does that mean?

00:18:46.190 --> 00:18:49.100 align:middle line:84%
If I go out and get myself a
21-millihenry inductor and I

00:18:49.100 --> 00:18:51.710 align:middle line:90%
plug it in, life's good.

00:18:51.710 --> 00:18:53.270 align:middle line:90%
I enjoy the magnetic fields.

00:18:53.270 --> 00:18:56.810 align:middle line:84%
If I instead brought my
19-millihenry inductor

00:18:56.810 --> 00:18:59.480 align:middle line:84%
and plugged it in, well, I'm
going to lose the breaker,

00:18:59.480 --> 00:19:02.120 align:middle line:84%
and I'm going to be
sitting in the dark.

00:19:02.120 --> 00:19:07.490 align:middle line:84%
So while the inductor doesn't
consume average power,

00:19:07.490 --> 00:19:11.690 align:middle line:84%
it does draw a mean
square current,

00:19:11.690 --> 00:19:17.310 align:middle line:84%
and it does degrade the ability
of me to utilize my source.

00:19:17.310 --> 00:19:19.340 align:middle line:90%
So I have two outlets here.

00:19:19.340 --> 00:19:22.173 align:middle line:84%
Suppose I'm putting in my
20-millihenry inductor.

00:19:22.173 --> 00:19:26.720 align:middle line:90%


00:19:26.720 --> 00:19:28.470 align:middle line:90%
And I can do that.

00:19:28.470 --> 00:19:29.750 align:middle line:90%
Life's good.

00:19:29.750 --> 00:19:30.720 align:middle line:90%
Nothing's going wrong.

00:19:30.720 --> 00:19:32.430 align:middle line:90%
I haven't exceeded the breaker.

00:19:32.430 --> 00:19:35.240 align:middle line:84%
But now if I want to
plug in my space heater

00:19:35.240 --> 00:19:37.010 align:middle line:84%
as well because
I'm feeling cold,

00:19:37.010 --> 00:19:42.300 align:middle line:84%
I'm out of luck because I'm
already drawing 15 amps RMS.

00:19:42.300 --> 00:19:47.160 align:middle line:84%
I draw any more current,
the breaker goes.

00:19:47.160 --> 00:19:52.120 align:middle line:84%
So plugging in the inductor
hasn't used any average energy,

00:19:52.120 --> 00:19:58.160 align:middle line:84%
but it has degraded my ability
to draw power from the source.

00:19:58.160 --> 00:20:01.700 align:middle line:84%
I've utilized the capability of
the source to deliver me energy,

00:20:01.700 --> 00:20:04.450 align:middle line:84%
even though I haven't
used the energy.

00:20:04.450 --> 00:20:08.780 align:middle line:90%
Any questions about that?

00:20:08.780 --> 00:20:11.900 align:middle line:84%
Now, as you might imagine,
the utility hates that.

00:20:11.900 --> 00:20:13.970 align:middle line:90%
Their job is to sell you energy.

00:20:13.970 --> 00:20:19.430 align:middle line:84%
And you're using up the capacity
without using up the energy.

00:20:19.430 --> 00:20:21.350 align:middle line:84%
So what people have
done is they've

00:20:21.350 --> 00:20:25.800 align:middle line:84%
come up with a measure
of energy utilization.

00:20:25.800 --> 00:20:30.500 align:middle line:84%
How well are you utilizing
the capability of the source

00:20:30.500 --> 00:20:32.390 align:middle line:90%
to deliver you energy?

00:20:32.390 --> 00:20:39.425 align:middle line:84%
And this measure is
known as power factor.

00:20:39.425 --> 00:20:50.580 align:middle line:84%
So power factor is
defined as follows.

00:20:50.580 --> 00:20:56.120 align:middle line:84%
It's the average power you're
drawing divided by the RMS

00:20:56.120 --> 00:20:59.425 align:middle line:90%
voltage times the RMS current.

00:20:59.425 --> 00:21:02.660 align:middle line:90%


00:21:02.660 --> 00:21:04.420 align:middle line:84%
Now, when I talk
about power factor,

00:21:04.420 --> 00:21:06.970 align:middle line:84%
we mean the power
factor at a port.

00:21:06.970 --> 00:21:08.523 align:middle line:90%
So I have some pair of wires.

00:21:08.523 --> 00:21:11.650 align:middle line:90%


00:21:11.650 --> 00:21:14.530 align:middle line:84%
And I look at this port, this
interface's two-wire pair,

00:21:14.530 --> 00:21:19.210 align:middle line:84%
and I'm talking about some
voltage v and some current i

00:21:19.210 --> 00:21:19.910 align:middle line:90%
here.

00:21:19.910 --> 00:21:22.690 align:middle line:84%
So it's basically relating
to the power that's

00:21:22.690 --> 00:21:24.390 align:middle line:90%
going across this dashed line.

00:21:24.390 --> 00:21:27.675 align:middle line:90%


00:21:27.675 --> 00:21:30.730 align:middle line:84%
And why do I choose
this measure?

00:21:30.730 --> 00:21:32.930 align:middle line:90%
Well, what would be--

00:21:32.930 --> 00:21:49.300 align:middle line:84%
If I had a resistor, the average
power is equal to VRMS IRMS.

00:21:49.300 --> 00:21:53.900 align:middle line:90%
So the power factor is one.

00:21:53.900 --> 00:21:58.880 align:middle line:84%
So I basically best utilize
that source as I can.

00:21:58.880 --> 00:22:01.420 align:middle line:84%
I'm drawing energy
out of the source,

00:22:01.420 --> 00:22:02.990 align:middle line:90%
and it's all going to me.

00:22:02.990 --> 00:22:06.520 align:middle line:84%
All the RMS current is
contributing to energy transfer

00:22:06.520 --> 00:22:11.890 align:middle line:84%
from the source to the load
or across this boundary.

00:22:11.890 --> 00:22:19.060 align:middle line:84%
If I had an inductor L or a
capacitor C, for that matter,

00:22:19.060 --> 00:22:21.850 align:middle line:84%
I'd have average
power is equal to 0,

00:22:21.850 --> 00:22:24.910 align:middle line:84%
and I'd have a
power factor of 0.

00:22:24.910 --> 00:22:28.660 align:middle line:84%
That means I'm utilizing up
the capability of the source

00:22:28.660 --> 00:22:32.770 align:middle line:84%
by drawing RMS current
but delivering no energy.

00:22:32.770 --> 00:22:37.510 align:middle line:84%
So the power factor has a
magnitude that's less than 1.

00:22:37.510 --> 00:22:40.120 align:middle line:84%
The best case from the
utility's perspective,

00:22:40.120 --> 00:22:42.430 align:middle line:84%
if your power factor
is 1, that means

00:22:42.430 --> 00:22:45.600 align:middle line:84%
all the current I'm drawing
is going to energy transfer.

00:22:45.600 --> 00:22:47.570 align:middle line:84%
The power factor
can go down to 0,

00:22:47.570 --> 00:22:49.760 align:middle line:84%
which means I'm drawing
current, but I'm not

00:22:49.760 --> 00:22:52.940 align:middle line:90%
drawing any power on average.

00:22:52.940 --> 00:22:58.310 align:middle line:84%
Any questions about
that general idea?

00:22:58.310 --> 00:22:58.810 align:middle line:90%
Yeah.

00:22:58.810 --> 00:23:00.560 align:middle line:84%
AUDIENCE: If you have
a power factor of 1,

00:23:00.560 --> 00:23:02.690 align:middle line:84%
then wouldn't all the
electricity we burned up

00:23:02.690 --> 00:23:05.718 align:middle line:90%
in the transmission lines?

00:23:05.718 --> 00:23:08.760 align:middle line:84%
DAVID PERREAULT:
Power factor of 1--

00:23:08.760 --> 00:23:12.750 align:middle line:84%
OK, first of all, the
transmission line--

00:23:12.750 --> 00:23:17.180 align:middle line:84%
when I talk about power factor,
I'm talking about it at a place.

00:23:17.180 --> 00:23:20.730 align:middle line:84%
So I'm talking about the voltage
here and the current here.

00:23:20.730 --> 00:23:24.210 align:middle line:84%
So power factor
doesn't concern itself

00:23:24.210 --> 00:23:28.740 align:middle line:84%
with what energy is being
dissipated elsewhere.

00:23:28.740 --> 00:23:37.360 align:middle line:84%
All it's saying is that
the current I'm using here

00:23:37.360 --> 00:23:40.720 align:middle line:84%
is doing the best possible
job of transferring energy

00:23:40.720 --> 00:23:45.010 align:middle line:84%
across this boundary
without wasting any of it.

00:23:45.010 --> 00:23:48.940 align:middle line:84%
That's not to say that there is
no dissipation back over here

00:23:48.940 --> 00:23:50.170 align:middle line:90%
somewhere.

00:23:50.170 --> 00:23:52.930 align:middle line:84%
And with a resistive
load, a power factor of 1

00:23:52.930 --> 00:23:58.620 align:middle line:84%
means you're doing as
little badness as you can.

00:23:58.620 --> 00:24:02.060 align:middle line:84%
In other words, in order to
draw energy in this example,

00:24:02.060 --> 00:24:04.360 align:middle line:84%
yeah, I am dissipating
something in the wire;

00:24:04.360 --> 00:24:07.470 align:middle line:84%
there is some loss for the
utility that they're paying for.

00:24:07.470 --> 00:24:12.290 align:middle line:84%
But I'm minimizing
the amount that's

00:24:12.290 --> 00:24:14.090 align:middle line:84%
getting burned in
the wiring resistance

00:24:14.090 --> 00:24:16.400 align:middle line:90%
to transfer energy to my load.

00:24:16.400 --> 00:24:19.650 align:middle line:84%
Whereas in the inductive case,
I was doing the opposite thing.

00:24:19.650 --> 00:24:24.440 align:middle line:84%
I was sort of not
taking any energy

00:24:24.440 --> 00:24:26.720 align:middle line:84%
but still causing
them to have to pay

00:24:26.720 --> 00:24:29.390 align:middle line:84%
for the loss in the
transmission line.

00:24:29.390 --> 00:24:30.300 align:middle line:90%
Does that make sense?

00:24:30.300 --> 00:24:31.415 align:middle line:90%
AUDIENCE: Thank you.

00:24:31.415 --> 00:24:35.380 align:middle line:84%
DAVID PERREAULT: Other
questions or comments?

00:24:35.380 --> 00:24:36.160 align:middle line:90%
Yeah.

00:24:36.160 --> 00:24:39.730 align:middle line:84%
AUDIENCE: So when we say the
average power out of port,

00:24:39.730 --> 00:24:41.890 align:middle line:84%
is the idea then
that it would be--

00:24:41.890 --> 00:24:45.600 align:middle line:84%
if you had some resistive
element at that port--

00:24:45.600 --> 00:24:46.850 align:middle line:90%
DAVID PERREAULT: Say it again.

00:24:46.850 --> 00:24:49.000 align:middle line:84%
AUDIENCE: If we say
average power out of port,

00:24:49.000 --> 00:24:52.045 align:middle line:84%
then it says if we were to
have some resistive element

00:24:52.045 --> 00:24:53.920 align:middle line:84%
at that port, that's
what it would be, right?

00:24:53.920 --> 00:24:54.795 align:middle line:90%
DAVID PERREAULT: Yes.

00:24:54.795 --> 00:24:57.100 align:middle line:84%
If I had some resistive
element on the-- yeah,

00:24:57.100 --> 00:24:59.720 align:middle line:84%
the question is, what is
the power at the port?

00:24:59.720 --> 00:25:02.170 align:middle line:84%
It's the power that's going
across this dashed line

00:25:02.170 --> 00:25:04.060 align:middle line:90%
on average.

00:25:04.060 --> 00:25:07.100 align:middle line:84%
So if I have a resistor over
here, that's where it's going.

00:25:07.100 --> 00:25:10.290 align:middle line:90%
Yes

00:25:10.290 --> 00:25:14.277 align:middle line:84%
OK, so we have this
notion of power factor.

00:25:14.277 --> 00:25:16.110 align:middle line:84%
And by the way, power
factor can technically

00:25:16.110 --> 00:25:18.810 align:middle line:90%
be between 1 and minus 1.

00:25:18.810 --> 00:25:21.060 align:middle line:84%
Minus 1-- a negative
number would just

00:25:21.060 --> 00:25:23.305 align:middle line:84%
suggest that actual power
is flowing that way.

00:25:23.305 --> 00:25:26.442 align:middle line:90%


00:25:26.442 --> 00:25:29.220 align:middle line:84%
But the utility is quite
concerned with power factor

00:25:29.220 --> 00:25:32.320 align:middle line:84%
and not to be confused with
actual power dissipation.

00:25:32.320 --> 00:25:38.970 align:middle line:84%
I should say, by the way, that
this average power is sometimes

00:25:38.970 --> 00:25:43.340 align:middle line:84%
known as a, quote,
unquote, "real power."

00:25:43.340 --> 00:25:46.670 align:middle line:90%


00:25:46.670 --> 00:25:50.480 align:middle line:84%
So if you talk, hear somebody
talk about real power,

00:25:50.480 --> 00:25:52.170 align:middle line:84%
that's what they're
talking about.

00:25:52.170 --> 00:26:01.250 align:middle line:84%
VRMS IRMS is what's known
as apparent power, which

00:26:01.250 --> 00:26:03.455 align:middle line:84%
is greater than or
equal to the real power.

00:26:03.455 --> 00:26:07.558 align:middle line:90%


00:26:07.558 --> 00:26:11.250 align:middle line:84%
And this is just saying,
what effective power would I

00:26:11.250 --> 00:26:14.310 align:middle line:84%
be drawing considering that I
have that much current and that

00:26:14.310 --> 00:26:18.065 align:middle line:84%
much voltage if it was
going into a resistive load?

00:26:18.065 --> 00:26:23.250 align:middle line:90%


00:26:23.250 --> 00:26:28.410 align:middle line:84%
So let's expand our thoughts
a little bit because I've

00:26:28.410 --> 00:26:31.440 align:middle line:84%
been so far talking about
resistors and inductors

00:26:31.440 --> 00:26:33.990 align:middle line:84%
and capacitors, which have the
characteristic that they all

00:26:33.990 --> 00:26:36.480 align:middle line:90%
draw sinusoidal waveforms.

00:26:36.480 --> 00:26:38.700 align:middle line:84%
So nothing wrong with
anything we've done so far,

00:26:38.700 --> 00:26:40.210 align:middle line:84%
but the world is
bigger than that.

00:26:40.210 --> 00:26:42.900 align:middle line:84%
And let's come back
and think about,

00:26:42.900 --> 00:26:47.520 align:middle line:84%
for example, the rectifier
we had from last time.

00:26:47.520 --> 00:26:51.900 align:middle line:84%
So last time, we said,
OK, I'm going to hook up

00:26:51.900 --> 00:26:53.480 align:middle line:90%
to some AC voltage source.

00:26:53.480 --> 00:26:58.000 align:middle line:90%


00:26:58.000 --> 00:26:59.710 align:middle line:84%
So I have a sinusoidal
voltage source,

00:26:59.710 --> 00:27:03.400 align:middle line:84%
and then that's coming
into some rectifier.

00:27:03.400 --> 00:27:09.580 align:middle line:84%
And I'm getting some output
current, which is ideally DC.

00:27:09.580 --> 00:27:14.440 align:middle line:84%
And maybe I would say, OK,
let's talk about this current

00:27:14.440 --> 00:27:18.520 align:middle line:84%
drawn from the
rectifier, i of t.

00:27:18.520 --> 00:27:20.470 align:middle line:90%
So what does that look like?

00:27:20.470 --> 00:27:26.050 align:middle line:84%
In the example we had last time,
if I have a sinusoidal voltage

00:27:26.050 --> 00:27:38.040 align:middle line:84%
source, for a power
converter circuit,

00:27:38.040 --> 00:27:41.190 align:middle line:84%
the best-case scenario is
it looks like a resistor

00:27:41.190 --> 00:27:43.330 align:middle line:84%
because that's when you
get power factor of 1.

00:27:43.330 --> 00:27:46.600 align:middle line:84%
Unfortunately, a lot of power
converters don't look like that.

00:27:46.600 --> 00:27:50.970 align:middle line:84%
And in fact, if we took the half
wave rectifier from last time

00:27:50.970 --> 00:27:53.100 align:middle line:84%
and I said, What did the
line current look like?

00:27:53.100 --> 00:27:54.270 align:middle line:90%
it would look like this.

00:27:54.270 --> 00:27:55.560 align:middle line:90%
It would look like--

00:27:55.560 --> 00:27:57.280 align:middle line:84%
in positive half
of the line cycle,

00:27:57.280 --> 00:28:00.000 align:middle line:84%
it would give me
some current Id.

00:28:00.000 --> 00:28:04.080 align:middle line:84%
And in the second half of the
line cycle, it would give me 0.

00:28:04.080 --> 00:28:06.000 align:middle line:90%
So I'd be drawing a square wave.

00:28:06.000 --> 00:28:09.278 align:middle line:84%
And in fact, in that half
wave rectifier waveform,

00:28:09.278 --> 00:28:11.070 align:middle line:84%
it's actually a square
wave with an offset,

00:28:11.070 --> 00:28:12.690 align:middle line:90%
particularly horrible.

00:28:12.690 --> 00:28:15.210 align:middle line:90%
And here's omega t.

00:28:15.210 --> 00:28:16.650 align:middle line:90%
This is pi.

00:28:16.650 --> 00:28:19.500 align:middle line:90%
And this is 2 pi.

00:28:19.500 --> 00:28:23.550 align:middle line:84%
So the point is, when we start
introducing power conversion,

00:28:23.550 --> 00:28:26.550 align:middle line:84%
we can also often
have nonlinear loads,

00:28:26.550 --> 00:28:28.440 align:middle line:84%
meaning that even
when I'm driving it

00:28:28.440 --> 00:28:31.950 align:middle line:84%
with a sinusoidal voltage, I
don't get a sinusoidal current.

00:28:31.950 --> 00:28:38.273 align:middle line:84%
So let's start to think about
how might I represent that case.

00:28:38.273 --> 00:28:41.920 align:middle line:90%


00:28:41.920 --> 00:28:44.870 align:middle line:84%
And this is particularly-- when
I did this half wave rectifier,

00:28:44.870 --> 00:28:48.770 align:middle line:84%
it was a half wave rectifier
with an inductive filter, which

00:28:48.770 --> 00:28:51.120 align:middle line:84%
draws that kind of
square, wavy waveform.

00:28:51.120 --> 00:28:55.520 align:middle line:84%
Well, let's think about
how I might represent

00:28:55.520 --> 00:28:57.040 align:middle line:90%
this current i of t.

00:28:57.040 --> 00:29:01.040 align:middle line:90%


00:29:01.040 --> 00:29:07.430 align:middle line:84%
One way to think about that
is in periodic steady state,

00:29:07.430 --> 00:29:10.520 align:middle line:90%
I get a periodic current, right?

00:29:10.520 --> 00:29:16.100 align:middle line:84%
So in PSS, what I'm
talking about right now,

00:29:16.100 --> 00:29:19.460 align:middle line:84%
I can represent i of t
with a Fourier series.

00:29:19.460 --> 00:29:23.510 align:middle line:84%
So i of t, we might write
this as the summation from n

00:29:23.510 --> 00:29:34.220 align:middle line:84%
equals 0 to infinity of I sub n
sine of n omega t plus phi sub

00:29:34.220 --> 00:29:35.390 align:middle line:90%
n.

00:29:35.390 --> 00:29:39.090 align:middle line:84%
This is one way I could
write a Fourier series.

00:29:39.090 --> 00:29:41.140 align:middle line:84%
We can find the
Fourier coefficients.

00:29:41.140 --> 00:29:44.820 align:middle line:84%
And just to be clear,
I'm defining phi 0

00:29:44.820 --> 00:29:49.710 align:middle line:84%
to be equal to pi over 2
or 90 degrees so that I

00:29:49.710 --> 00:29:51.790 align:middle line:90%
sub 0 is just the DC component.

00:29:51.790 --> 00:29:57.120 align:middle line:90%


00:29:57.120 --> 00:30:04.110 align:middle line:84%
OK, well, I can represent this
pink waveform or any other AC

00:30:04.110 --> 00:30:07.890 align:middle line:84%
waveform that's not sinusoidal
as long as it's periodic

00:30:07.890 --> 00:30:09.580 align:middle line:90%
with some Fourier series.

00:30:09.580 --> 00:30:15.380 align:middle line:84%
You can relatively easily show
what the RMS of that waveform

00:30:15.380 --> 00:30:15.880 align:middle line:90%
is.

00:30:15.880 --> 00:30:18.213 align:middle line:84%
If I have-- if I break it
down with this Fourier series,

00:30:18.213 --> 00:30:20.410 align:middle line:90%
we could write RMS as follows.

00:30:20.410 --> 00:30:29.610 align:middle line:84%
IRMS is simply equal to the
square root of I0 squared plus

00:30:29.610 --> 00:30:38.160 align:middle line:84%
1/2 I1 squared plus 1/2 half
In squared and so forth.

00:30:38.160 --> 00:30:43.210 align:middle line:84%
So it becomes the
sum of the squares.

00:30:43.210 --> 00:30:47.160 align:middle line:84%
The halves are because of the
mean square of the individual

00:30:47.160 --> 00:30:51.090 align:middle line:84%
components, and I0 is constant,
so it doesn't have 1/2.

00:30:51.090 --> 00:30:52.840 align:middle line:90%
How do you find this?

00:30:52.840 --> 00:30:55.320 align:middle line:84%
Well, you could just
apply the definition

00:30:55.320 --> 00:30:58.600 align:middle line:84%
of RMS with this waveform
and then use orthogonality,

00:30:58.600 --> 00:30:59.445 align:middle line:90%
and it'll pop out.

00:30:59.445 --> 00:31:03.750 align:middle line:90%


00:31:03.750 --> 00:31:09.930 align:middle line:84%
So fine, I can express
my RMS current.

00:31:09.930 --> 00:31:13.100 align:middle line:84%
How would I write
the power associated

00:31:13.100 --> 00:31:14.910 align:middle line:90%
with that waveform given this?

00:31:14.910 --> 00:31:17.810 align:middle line:84%
Well, what I could do
is I could say this.

00:31:17.810 --> 00:31:25.070 align:middle line:84%
The average power, PAv, I
could write as v of t times

00:31:25.070 --> 00:31:27.330 align:middle line:84%
the average of v
of t times i of t.

00:31:27.330 --> 00:31:34.060 align:middle line:84%
So this would be 1 over 2 pi
integral from 0 to 2 pi of Vs

00:31:34.060 --> 00:31:44.120 align:middle line:84%
sine omega t times the
summation n equals 0

00:31:44.120 --> 00:31:52.805 align:middle line:84%
to infinity I sub n sine of n
omega t plus phi sub n d omega

00:31:52.805 --> 00:31:53.305 align:middle line:90%
t.

00:31:53.305 --> 00:31:56.540 align:middle line:90%


00:31:56.540 --> 00:32:00.590 align:middle line:84%
So I've got this
integral of a product.

00:32:00.590 --> 00:32:06.800 align:middle line:84%
I can interchange my summation
and integration here.

00:32:06.800 --> 00:32:08.600 align:middle line:90%
So what would this give me?

00:32:08.600 --> 00:32:18.320 align:middle line:84%
This would give me 1
over 2 pi Vs I sub 1--

00:32:18.320 --> 00:32:24.500 align:middle line:84%
I'm sorry, 1 over 2
pi V sub s, sorry--

00:32:24.500 --> 00:32:34.030 align:middle line:84%
summation n equals
0 to infinity of I

00:32:34.030 --> 00:32:45.715 align:middle line:84%
sub n sine of omega t sine
of n omega t d omega t.

00:32:45.715 --> 00:32:49.515 align:middle line:84%
Does that makes
sense to everybody?

00:32:49.515 --> 00:32:52.090 align:middle line:84%
AUDIENCE: Shouldn't there
be an integral as well?

00:32:52.090 --> 00:32:54.298 align:middle line:84%
DAVID PERREAULT: There should
be an integral in here,

00:32:54.298 --> 00:32:59.700 align:middle line:90%
shouldn't there/ Thank you.

00:32:59.700 --> 00:33:03.630 align:middle line:84%
So all I've done is I've
pulled out the summation.

00:33:03.630 --> 00:33:05.020 align:middle line:90%
But look at this.

00:33:05.020 --> 00:33:07.080 align:middle line:90%
What would you tell me--

00:33:07.080 --> 00:33:09.980 align:middle line:84%
and this should be sine
omega t plus phi sub n.

00:33:09.980 --> 00:33:15.390 align:middle line:90%


00:33:15.390 --> 00:33:17.810 align:middle line:84%
What would you tell me
about this integral here?

00:33:17.810 --> 00:33:21.600 align:middle line:90%


00:33:21.600 --> 00:33:27.596 align:middle line:84%
Well, if n is not equal to
1, what is this integral?

00:33:27.596 --> 00:33:28.290 align:middle line:90%
AUDIENCE: 0.

00:33:28.290 --> 00:33:30.690 align:middle line:84%
DAVID PERREAULT: 0
because sinusoids

00:33:30.690 --> 00:33:33.280 align:middle line:84%
at different frequencies
are orthogonal.

00:33:33.280 --> 00:33:37.560 align:middle line:84%
So I can throw every other term
but the n equal 1 term away.

00:33:37.560 --> 00:33:39.303 align:middle line:84%
And so what I'm
going to get is--

00:33:39.303 --> 00:33:41.950 align:middle line:90%


00:33:41.950 --> 00:33:44.270 align:middle line:84%
and I can put this
1 over 2 pi here.

00:33:44.270 --> 00:33:49.180 align:middle line:84%
And if we come back to my
original equation here,

00:33:49.180 --> 00:33:51.470 align:middle line:90%
I have that 1 over 2 pi here.

00:33:51.470 --> 00:34:02.190 align:middle line:84%
So what I get is Vs times
I1 over 2 cosine of phi 1.

00:34:02.190 --> 00:34:05.540 align:middle line:90%


00:34:05.540 --> 00:34:11.469 align:middle line:84%
So the nice thing is that
everything drops out.

00:34:11.469 --> 00:34:13.350 align:middle line:90%
So what does this tell me?

00:34:13.350 --> 00:34:18.330 align:middle line:84%
This says, if I have
this distorted waveform,

00:34:18.330 --> 00:34:20.850 align:middle line:84%
it's no longer a sinusoid,
this pink current

00:34:20.850 --> 00:34:24.360 align:middle line:84%
that has a whole bunch
of harmonic junk in it.

00:34:24.360 --> 00:34:29.159 align:middle line:84%
The only part of that that
contributes to average power,

00:34:29.159 --> 00:34:34.810 align:middle line:84%
to real power, is the
fundamental of the current

00:34:34.810 --> 00:34:37.060 align:middle line:84%
because every other
current component

00:34:37.060 --> 00:34:40.510 align:middle line:84%
at all other frequencies,
DC and all harmonics,

00:34:40.510 --> 00:34:42.224 align:middle line:90%
is orthogonal to the voltage.

00:34:42.224 --> 00:34:44.989 align:middle line:90%


00:34:44.989 --> 00:34:48.710 align:middle line:84%
Moreover, it's not
just the fundamental,

00:34:48.710 --> 00:34:52.550 align:middle line:84%
but it depends upon the
cosine of that fundamental.

00:34:52.550 --> 00:34:55.280 align:middle line:84%
In other words, it's only the
component of the fundamental

00:34:55.280 --> 00:34:58.340 align:middle line:84%
that's in phase
with the voltage.

00:34:58.340 --> 00:35:01.770 align:middle line:84%
If phi 1 was 0, cosine
of phi 1 would be 1.

00:35:01.770 --> 00:35:05.990 align:middle line:84%
So if I decomposed the current,
the fundamental current

00:35:05.990 --> 00:35:08.543 align:middle line:84%
into something that was
in phase with the voltage

00:35:08.543 --> 00:35:10.460 align:middle line:84%
and something that was
90 degrees out of phase

00:35:10.460 --> 00:35:11.127 align:middle line:90%
of the voltage--

00:35:11.127 --> 00:35:13.310 align:middle line:84%
I can split it up
that way-- only

00:35:13.310 --> 00:35:15.350 align:middle line:84%
the component that's in
phase with the voltage

00:35:15.350 --> 00:35:18.590 align:middle line:90%
contributes to energy transfer.

00:35:18.590 --> 00:35:24.020 align:middle line:84%
So if I want to transfer
energy, the only part

00:35:24.020 --> 00:35:25.910 align:middle line:84%
of that pink waveform
that's helping me

00:35:25.910 --> 00:35:29.390 align:middle line:84%
is the part at the frequency
of the sine wave of voltage

00:35:29.390 --> 00:35:33.795 align:middle line:84%
and only the piece of
that fundamental component

00:35:33.795 --> 00:35:35.170 align:middle line:84%
that's in phase
with the voltage.

00:35:35.170 --> 00:35:37.960 align:middle line:90%


00:35:37.960 --> 00:35:39.640 align:middle line:90%
I could rewrite this--

00:35:39.640 --> 00:35:43.600 align:middle line:84%
Remember that for
a sinusoid, the RMS

00:35:43.600 --> 00:35:46.490 align:middle line:84%
is 1 over the square root
of 2 times the peak value.

00:35:46.490 --> 00:35:58.590 align:middle line:84%
So I could have rewritten this
as VRMS I1 RMS cosine of phi 1.

00:35:58.590 --> 00:36:01.330 align:middle line:90%


00:36:01.330 --> 00:36:08.780 align:middle line:84%
That's just to say that this 1/2
comes from the RMS component.

00:36:08.780 --> 00:36:12.660 align:middle line:90%
So I can write it this way too.

00:36:12.660 --> 00:36:17.440 align:middle line:84%
So what does this say
about power factor?

00:36:17.440 --> 00:36:20.447 align:middle line:84%
Well, I can write this
average power factor.

00:36:20.447 --> 00:36:22.030 align:middle line:84%
So now that I can
write it, I can say,

00:36:22.030 --> 00:36:24.250 align:middle line:90%
what is the power factor?

00:36:24.250 --> 00:36:26.500 align:middle line:84%
And when I'm saying
what is the power

00:36:26.500 --> 00:36:28.930 align:middle line:84%
factor, in this
particular example,

00:36:28.930 --> 00:36:32.770 align:middle line:84%
I'm saying, what's the power
factor at this port right

00:36:32.770 --> 00:36:34.960 align:middle line:84%
here, at the
rectifier input port?

00:36:34.960 --> 00:36:38.050 align:middle line:84%
Because I have this current
and Vs sine omega t.

00:36:38.050 --> 00:36:41.020 align:middle line:90%


00:36:41.020 --> 00:36:49.510 align:middle line:84%
The power factor is simply going
to be the average power, which

00:36:49.510 --> 00:37:00.430 align:middle line:84%
is VRMS times I1 RMS, the RMS of
just the fundamental component,

00:37:00.430 --> 00:37:07.510 align:middle line:84%
times the cosine of the
fundamental phase of the current

00:37:07.510 --> 00:37:11.163 align:middle line:90%
divided by VRMS IRMS.

00:37:11.163 --> 00:37:14.440 align:middle line:90%


00:37:14.440 --> 00:37:18.550 align:middle line:84%
Or I could cancel out VRMS
because they're both just

00:37:18.550 --> 00:37:20.260 align:middle line:90%
the RMS of a sine wave.

00:37:20.260 --> 00:37:28.750 align:middle line:84%
And this would give
us I1 RMS over IRMS

00:37:28.750 --> 00:37:31.140 align:middle line:90%
times the cosine of phi 1.

00:37:31.140 --> 00:37:35.476 align:middle line:90%


00:37:35.476 --> 00:37:39.050 align:middle line:90%
This decomposition is useful.

00:37:39.050 --> 00:37:43.270 align:middle line:84%
This piece here is
sometimes called k sub

00:37:43.270 --> 00:37:45.300 align:middle line:90%
d, the distortion factor.

00:37:45.300 --> 00:37:51.190 align:middle line:90%


00:37:51.190 --> 00:37:52.970 align:middle line:90%
What's it a measure of?

00:37:52.970 --> 00:37:59.140 align:middle line:84%
It's saying, look, this is
the IRMS of the whole thing.

00:37:59.140 --> 00:38:11.550 align:middle line:84%
I1 RMS is simply equal to the
square root of 1/2 I1 squared.

00:38:11.550 --> 00:38:16.050 align:middle line:84%
So it's saying
this is a measure--

00:38:16.050 --> 00:38:18.540 align:middle line:84%
this factor, this
distortion factor

00:38:18.540 --> 00:38:23.430 align:middle line:84%
is a measure of how much
the harmonic content is

00:38:23.430 --> 00:38:25.830 align:middle line:90%
degrading my power factor.

00:38:25.830 --> 00:38:28.350 align:middle line:84%
I just told you that all
the harmonic content doesn't

00:38:28.350 --> 00:38:30.020 align:middle line:90%
help you transfer energy.

00:38:30.020 --> 00:38:32.140 align:middle line:84%
That means it's degrading
your power factor.

00:38:32.140 --> 00:38:35.100 align:middle line:84%
So this number kd is
clearly some number

00:38:35.100 --> 00:38:39.000 align:middle line:90%
of magnitude less than 1.

00:38:39.000 --> 00:38:43.530 align:middle line:84%
If it's a pure sinusoid, I1
one of RMS is equal to IRMS.

00:38:43.530 --> 00:38:45.400 align:middle line:90%
And so that becomes 1.

00:38:45.400 --> 00:38:49.080 align:middle line:84%
But when I start to add in
any harmonic components or DC

00:38:49.080 --> 00:38:53.160 align:middle line:84%
components, IRMS becomes
bigger than I1 of RMS,

00:38:53.160 --> 00:38:54.960 align:middle line:84%
and this distortion
factor starts

00:38:54.960 --> 00:38:56.345 align:middle line:90%
degrading my power factor.

00:38:56.345 --> 00:38:59.800 align:middle line:90%


00:38:59.800 --> 00:39:03.910 align:middle line:84%
This here is sometimes
called k theta

00:39:03.910 --> 00:39:05.460 align:middle line:90%
or the displacement factor.

00:39:05.460 --> 00:39:10.630 align:middle line:90%


00:39:10.630 --> 00:39:14.025 align:middle line:84%
And phi 1 is sometimes called
the power factor angle.

00:39:14.025 --> 00:39:19.510 align:middle line:90%


00:39:19.510 --> 00:39:21.760 align:middle line:84%
This is saying,
suppose I had a--

00:39:21.760 --> 00:39:24.320 align:middle line:84%
suppose my distortion
factor was just 1--

00:39:24.320 --> 00:39:27.970 align:middle line:90%
there's no distortion.

00:39:27.970 --> 00:39:32.940 align:middle line:84%
Well, if my phase angle phi
1 of the current with respect

00:39:32.940 --> 00:39:35.250 align:middle line:84%
to the voltage is 0--
they're in phase--

00:39:35.250 --> 00:39:37.410 align:middle line:90%
then this becomes 1.

00:39:37.410 --> 00:39:41.620 align:middle line:84%
As the current starts to get
out of phase with the voltage,

00:39:41.620 --> 00:39:46.530 align:middle line:84%
this cosine of phi 1 has
a magnitude less than 1.

00:39:46.530 --> 00:39:48.800 align:middle line:84%
So we can hurt our
power factor, we

00:39:48.800 --> 00:39:54.248 align:middle line:84%
can hurt our ability to utilize
the source to transfer energy.

00:39:54.248 --> 00:39:56.040 align:middle line:84%
It's not how much energy
we're dissipating.

00:39:56.040 --> 00:39:58.530 align:middle line:84%
It's how much
utilization do we have.

00:39:58.530 --> 00:40:00.670 align:middle line:90%
I can damage it in two ways.

00:40:00.670 --> 00:40:03.870 align:middle line:84%
I can damage it by drawing a
bunch of harmonic current that

00:40:03.870 --> 00:40:10.325 align:middle line:84%
doesn't deliver power or by
delivering components of current

00:40:10.325 --> 00:40:12.200 align:middle line:84%
that are out of phase
with the voltage, which

00:40:12.200 --> 00:40:14.160 align:middle line:90%
also doesn't deliver power.

00:40:14.160 --> 00:40:18.470 align:middle line:84%
So this is kind of a
very useful way sometimes

00:40:18.470 --> 00:40:24.670 align:middle line:90%
to decompose what's going on.

00:40:24.670 --> 00:40:28.170 align:middle line:84%
Because if I really cared
about the power factor,

00:40:28.170 --> 00:40:29.710 align:middle line:90%
I might need to know that.

00:40:29.710 --> 00:40:31.450 align:middle line:84%
And you say, well,
why is that true?

00:40:31.450 --> 00:40:34.770 align:middle line:84%
Because suppose I connected
up a rectifier like this

00:40:34.770 --> 00:40:39.240 align:middle line:84%
with drawing the
square wave current.

00:40:39.240 --> 00:40:40.830 align:middle line:84%
First of all, this
would be horrible

00:40:40.830 --> 00:40:43.568 align:middle line:84%
because it has a DC value,
which a lot of transformers

00:40:43.568 --> 00:40:44.360 align:middle line:90%
doesn't let you do.

00:40:44.360 --> 00:40:45.705 align:middle line:90%
But suppose I put that aside.

00:40:45.705 --> 00:40:48.330 align:middle line:90%


00:40:48.330 --> 00:40:54.300 align:middle line:84%
Within my 15-amp limit, I have
a limited amount of power I can

00:40:54.300 --> 00:40:58.740 align:middle line:84%
draw with this rectifier
just because of the harmonic

00:40:58.740 --> 00:40:59.790 align:middle line:90%
currents.

00:40:59.790 --> 00:41:01.860 align:middle line:84%
The fundamental of
this pink waveform

00:41:01.860 --> 00:41:04.450 align:middle line:84%
is actually in phase
with the voltage.

00:41:04.450 --> 00:41:07.260 align:middle line:84%
So I'm not hurting
myself by having

00:41:07.260 --> 00:41:10.560 align:middle line:84%
phase shifts like I did with
an inductor or capacitor.

00:41:10.560 --> 00:41:13.710 align:middle line:84%
But I am hurting myself or
limiting the amount of power

00:41:13.710 --> 00:41:17.010 align:middle line:84%
I can draw by the
fact that there's

00:41:17.010 --> 00:41:20.220 align:middle line:84%
a certain amount of
nonfundamental component

00:41:20.220 --> 00:41:22.170 align:middle line:90%
in the current waveform.

00:41:22.170 --> 00:41:26.740 align:middle line:84%
Well, if I got rid of the
DC component, for example,

00:41:26.740 --> 00:41:30.700 align:middle line:84%
suddenly my RMS would go
down and my power transfer

00:41:30.700 --> 00:41:31.630 align:middle line:90%
would stay the same.

00:41:31.630 --> 00:41:33.110 align:middle line:90%
And I'd be a happier camper.

00:41:33.110 --> 00:41:35.650 align:middle line:84%
That might be one thing
I could do, for example.

00:41:35.650 --> 00:41:40.490 align:middle line:84%
But these kind of calculations
can tell you, how are you--

00:41:40.490 --> 00:41:43.303 align:middle line:84%
what should you do to do better
utilization of your source?

00:41:43.303 --> 00:41:45.720 align:middle line:84%
Whereas the best thing you can
do is look like a resistor.

00:41:45.720 --> 00:41:48.291 align:middle line:90%


00:41:48.291 --> 00:41:51.910 align:middle line:84%
Any questions about
any of this so far?

00:41:51.910 --> 00:41:52.450 align:middle line:90%
Yeah.

00:41:52.450 --> 00:41:54.075 align:middle line:84%
AUDIENCE: You made
a couple of comments

00:41:54.075 --> 00:41:56.560 align:middle line:84%
about utilities caring
a lot about this.

00:41:56.560 --> 00:41:58.660 align:middle line:84%
It seems like all of
the stuff that this

00:41:58.660 --> 00:42:00.380 align:middle line:90%
involves is on the user's end.

00:42:00.380 --> 00:42:02.290 align:middle line:84%
Can the utility do
anything about this?

00:42:02.290 --> 00:42:04.360 align:middle line:84%
Or is it just they wish
we could do better?

00:42:04.360 --> 00:42:08.590 align:middle line:84%
DAVID PERREAULT: Yeah, that's
a very, very good question.

00:42:08.590 --> 00:42:13.090 align:middle line:84%
The answer is if you are an
industrial user of power,

00:42:13.090 --> 00:42:16.030 align:middle line:84%
if you're running a
big factory that's

00:42:16.030 --> 00:42:18.940 align:middle line:84%
drawing lots of electricity for
whatever your industrial process

00:42:18.940 --> 00:42:21.733 align:middle line:84%
is, yes, the utility
can come and say,

00:42:21.733 --> 00:42:22.900 align:middle line:90%
you've got to clean this up.

00:42:22.900 --> 00:42:25.540 align:middle line:84%
Or what they really do is they
start charging if your power

00:42:25.540 --> 00:42:26.945 align:middle line:90%
factor is not good enough.

00:42:26.945 --> 00:42:28.570 align:middle line:84%
And then you go clean
it up because you

00:42:28.570 --> 00:42:30.660 align:middle line:90%
don't want to pay them.

00:42:30.660 --> 00:42:34.060 align:middle line:90%
So that's one way it's limited.

00:42:34.060 --> 00:42:35.630 align:middle line:90%
But you're absolutely right.

00:42:35.630 --> 00:42:37.550 align:middle line:84%
There are some
perverse incentives.

00:42:37.550 --> 00:42:43.430 align:middle line:84%
So increasingly, for
different kinds of loads,

00:42:43.430 --> 00:42:46.030 align:middle line:84%
requirements are being
placed on the quality

00:42:46.030 --> 00:42:47.660 align:middle line:90%
of the waveforms drawn.

00:42:47.660 --> 00:42:50.690 align:middle line:90%
And that's a very complex thing.

00:42:50.690 --> 00:42:53.690 align:middle line:84%
In some cases, they
actually quote power factor.

00:42:53.690 --> 00:42:56.020 align:middle line:84%
In some cases, they
quote other measures.

00:42:56.020 --> 00:42:58.133 align:middle line:84%
Like, they assume
that your phase

00:42:58.133 --> 00:42:59.800 align:middle line:84%
angle is going to be
happy, but how much

00:42:59.800 --> 00:43:01.400 align:middle line:90%
distortion do you put in?

00:43:01.400 --> 00:43:04.450 align:middle line:84%
And that becomes-- if
you want your Energy Star

00:43:04.450 --> 00:43:06.400 align:middle line:84%
rating, for example,
on your appliance,

00:43:06.400 --> 00:43:08.750 align:middle line:84%
then suddenly you've
got to meet that.

00:43:08.750 --> 00:43:11.680 align:middle line:84%
Or if you want to sell
a computer power supply,

00:43:11.680 --> 00:43:16.640 align:middle line:84%
there are certain
standards you have to meet.

00:43:16.640 --> 00:43:19.360 align:middle line:84%
But those are a
little bit haphazard

00:43:19.360 --> 00:43:22.580 align:middle line:84%
because people were doing
all kinds of nasty stuff

00:43:22.580 --> 00:43:24.830 align:middle line:84%
to the grid back in the day
and nobody paid attention.

00:43:24.830 --> 00:43:27.038 align:middle line:84%
And now they're trying to
clean it up after the fact.

00:43:27.038 --> 00:43:30.460 align:middle line:84%
So it's mostly if you're a
big industrial user of energy

00:43:30.460 --> 00:43:34.060 align:middle line:84%
that they're really
regulating your power factor.

00:43:34.060 --> 00:43:36.880 align:middle line:84%
But increasingly with other
kinds of loads, especially

00:43:36.880 --> 00:43:39.610 align:middle line:84%
as new kinds of power
supplies and things come up,

00:43:39.610 --> 00:43:42.410 align:middle line:84%
there are more and more
strict regulations.

00:43:42.410 --> 00:43:43.640 align:middle line:90%
But excellent question.

00:43:43.640 --> 00:43:44.955 align:middle line:90%
Other questions or thoughts?

00:43:44.955 --> 00:43:49.520 align:middle line:90%


00:43:49.520 --> 00:43:52.886 align:middle line:84%
OK, I should point out one
thing about this breakdown.

00:43:52.886 --> 00:43:56.990 align:middle line:90%


00:43:56.990 --> 00:43:59.570 align:middle line:84%
This whole breakdown
into distortion factor

00:43:59.570 --> 00:44:03.050 align:middle line:84%
and displacement
factor worked because I

00:44:03.050 --> 00:44:05.270 align:middle line:84%
assumed that the
voltage was a sinusoid

00:44:05.270 --> 00:44:07.620 align:middle line:84%
and that the current
might have harmonics.

00:44:07.620 --> 00:44:10.670 align:middle line:84%
I could have done the
same kind of breakdown

00:44:10.670 --> 00:44:14.190 align:middle line:84%
if the current was a sinusoid
and the voltage had harmonics.

00:44:14.190 --> 00:44:17.780 align:middle line:84%
In that case, it would
just be V1 RMS over VRMS

00:44:17.780 --> 00:44:20.300 align:middle line:84%
and then cosine of
the phase shift.

00:44:20.300 --> 00:44:23.900 align:middle line:84%
If you have both the
voltage is not sinusoidal

00:44:23.900 --> 00:44:26.180 align:middle line:84%
and the current
is not sinusoidal,

00:44:26.180 --> 00:44:29.210 align:middle line:84%
you can't break
things down this way.

00:44:29.210 --> 00:44:33.440 align:middle line:84%
You can, however, still
calculate power factor.

00:44:33.440 --> 00:44:35.330 align:middle line:84%
And it turns out
that the way you

00:44:35.330 --> 00:44:38.245 align:middle line:84%
get a power factor of 1,
which is the best you can do,

00:44:38.245 --> 00:44:39.620 align:middle line:84%
is you make your
current waveform

00:44:39.620 --> 00:44:41.287 align:middle line:84%
look exactly like
your voltage waveform.

00:44:41.287 --> 00:44:43.820 align:middle line:84%
It has the same harmonic
content and the same phase

00:44:43.820 --> 00:44:45.240 align:middle line:90%
shift at every frequency.

00:44:45.240 --> 00:44:48.020 align:middle line:84%
And that's the best you
can do to transfer energy.

00:44:48.020 --> 00:44:52.040 align:middle line:84%
And you can think about
it as transfer the least--

00:44:52.040 --> 00:44:56.430 align:middle line:84%
the most energy per unit loss
back in the source somewhere

00:44:56.430 --> 00:44:58.370 align:middle line:84%
is the way you might
think about that.

00:44:58.370 --> 00:45:02.299 align:middle line:90%


00:45:02.299 --> 00:45:07.060 align:middle line:84%
Any other questions before we
show you some of these things?

00:45:07.060 --> 00:45:07.900 align:middle line:90%
Yeah.

00:45:07.900 --> 00:45:10.570 align:middle line:84%
AUDIENCE: Is there
any intuitive way

00:45:10.570 --> 00:45:14.460 align:middle line:84%
to understand where
the parent power is

00:45:14.460 --> 00:45:18.820 align:middle line:90%
going from harmonic components?

00:45:18.820 --> 00:45:24.408 align:middle line:84%
Like, what is actually
causing that distortion?

00:45:24.408 --> 00:45:25.950 align:middle line:84%
DAVID PERREAULT:
Well, what's causing

00:45:25.950 --> 00:45:28.740 align:middle line:84%
the distortion has something
to do with the circuit.

00:45:28.740 --> 00:45:33.500 align:middle line:84%
So this is all posited on
I have a voltage waveform

00:45:33.500 --> 00:45:34.750 align:middle line:90%
and I have a current waveform.

00:45:34.750 --> 00:45:36.810 align:middle line:84%
And suppose the
current is distorted.

00:45:36.810 --> 00:45:40.530 align:middle line:84%
So what's causing all that
has to do with the circuit?

00:45:40.530 --> 00:45:44.150 align:middle line:84%
The way you might
think about the impact

00:45:44.150 --> 00:45:52.280 align:middle line:84%
is very much in thinking about
how does the harmonics content--

00:45:52.280 --> 00:45:54.950 align:middle line:84%
this comes back to the
fact that sinusoids

00:45:54.950 --> 00:45:57.500 align:middle line:84%
at different frequencies
are orthogonal.

00:45:57.500 --> 00:46:00.800 align:middle line:84%
And so you degrade
your energy transport

00:46:00.800 --> 00:46:02.690 align:middle line:90%
because of that orthogonality.

00:46:02.690 --> 00:46:06.110 align:middle line:84%
And sine and cosine at a
given frequency is orthogonal,

00:46:06.110 --> 00:46:07.598 align:middle line:84%
and that causes
this degradation.

00:46:07.598 --> 00:46:09.140 align:middle line:84%
So that's the way
I would look at it.

00:46:09.140 --> 00:46:12.060 align:middle line:84%
In terms of what's causing
that or how do you fix that,

00:46:12.060 --> 00:46:16.360 align:middle line:84%
that's more of a circuit thing
or a system design issue.

00:46:16.360 --> 00:46:19.530 align:middle line:90%


00:46:19.530 --> 00:46:21.480 align:middle line:90%
OK, let's do a demo.

00:46:21.480 --> 00:46:25.480 align:middle line:84%
[INAUDIBLE] has very
kindly set this up.

00:46:25.480 --> 00:46:27.630 align:middle line:84%
And what this is, this
is a piece of equipment

00:46:27.630 --> 00:46:33.090 align:middle line:84%
that's designed to look at line
waveforms and measure power

00:46:33.090 --> 00:46:34.950 align:middle line:84%
factor and other
things of signals.

00:46:34.950 --> 00:46:41.130 align:middle line:84%
So basically, things that get
plugged into this power strip,

00:46:41.130 --> 00:46:46.950 align:middle line:84%
this box analyzes the voltage
and the current waveform

00:46:46.950 --> 00:46:49.810 align:middle line:84%
and then computes things
like power factor for you.

00:46:49.810 --> 00:46:52.470 align:middle line:84%
And I don't know what this
particular Yokogawa power

00:46:52.470 --> 00:46:53.770 align:middle line:90%
analyzer cost.

00:46:53.770 --> 00:46:55.350 align:middle line:90%
I think it was under $10k.

00:46:55.350 --> 00:46:58.525 align:middle line:84%
So for you, if you want one
at home, you can go buy one.

00:46:58.525 --> 00:47:00.400 align:middle line:84%
Actually, you can get
one cheaper these days.

00:47:00.400 --> 00:47:03.720 align:middle line:90%
But that's about what this cost.

00:47:03.720 --> 00:47:05.880 align:middle line:84%
So what you can
see here is she has

00:47:05.880 --> 00:47:07.480 align:middle line:90%
the voltage waveform running.

00:47:07.480 --> 00:47:09.180 align:middle line:84%
It's 110 volts, but
there's no current

00:47:09.180 --> 00:47:10.930 align:middle line:84%
because she has
nothing plugged in.

00:47:10.930 --> 00:47:12.305 align:middle line:84%
Now, [INAUDIBLE]
is going to plug

00:47:12.305 --> 00:47:15.180 align:middle line:84%
in a traditional
incandescent light bulb.

00:47:15.180 --> 00:47:17.850 align:middle line:90%
Here we go.

00:47:17.850 --> 00:47:23.390 align:middle line:84%
Lambda 4 up there,
for whatever reason,

00:47:23.390 --> 00:47:26.000 align:middle line:84%
is the symbol they're
using for power factor.

00:47:26.000 --> 00:47:27.500 align:middle line:84%
But what you can
see is the current,

00:47:27.500 --> 00:47:30.470 align:middle line:84%
which is in purple, is
basically sinusoidal

00:47:30.470 --> 00:47:32.370 align:middle line:84%
and in phase with
our nice voltage.

00:47:32.370 --> 00:47:34.927 align:middle line:84%
And so we get a
power factor of 1.

00:47:34.927 --> 00:47:37.010 align:middle line:84%
And you can see she does
a nice job of lighting up

00:47:37.010 --> 00:47:40.160 align:middle line:84%
this kind of very
Edisonian bulb.

00:47:40.160 --> 00:47:42.510 align:middle line:90%
So thanks.

00:47:42.510 --> 00:47:44.310 align:middle line:84%
And one thing I
didn't point out,

00:47:44.310 --> 00:47:45.930 align:middle line:90%
that was about 50 watts there.

00:47:45.930 --> 00:47:49.760 align:middle line:84%
So that kind of makes sense
for that kind of brightness.

00:47:49.760 --> 00:47:52.430 align:middle line:84%
What [INAUDIBLE] is
going to plug in right

00:47:52.430 --> 00:47:55.945 align:middle line:90%
now is a fluorescent light bulb.

00:47:55.945 --> 00:47:58.480 align:middle line:90%


00:47:58.480 --> 00:48:01.780 align:middle line:84%
And there we're actually getting
a lot brighter light here.

00:48:01.780 --> 00:48:05.260 align:middle line:84%
This is brighter than the
incandescent light bulb.

00:48:05.260 --> 00:48:08.240 align:middle line:84%
Notice that we're only
drawing about 12 watts.

00:48:08.240 --> 00:48:11.348 align:middle line:84%
So from an energy consumption,
just purely how much power we're

00:48:11.348 --> 00:48:13.390 align:middle line:84%
drawing from the grid,
this is a way better deal,

00:48:13.390 --> 00:48:15.950 align:middle line:84%
even though the light's
kind of not as nice.

00:48:15.950 --> 00:48:19.150 align:middle line:84%
And if we did an LED bulb,
it would be even better.

00:48:19.150 --> 00:48:22.540 align:middle line:84%
But look at the
current waveform.

00:48:22.540 --> 00:48:27.010 align:middle line:84%
That current waveform, the
purple, is absolutely horrible.

00:48:27.010 --> 00:48:29.600 align:middle line:84%
It's massively dominated
by its harmonics.

00:48:29.600 --> 00:48:34.360 align:middle line:84%
You can visually see that, yeah,
it has a fundamental component,

00:48:34.360 --> 00:48:36.400 align:middle line:90%
but it's pretty bad, right?

00:48:36.400 --> 00:48:39.100 align:middle line:84%
The reason, this has a
diode rectifier in it

00:48:39.100 --> 00:48:40.280 align:middle line:90%
at the front end.

00:48:40.280 --> 00:48:42.610 align:middle line:84%
But instead of running it
with an inductive filter,

00:48:42.610 --> 00:48:44.030 align:middle line:90%
they used a capacitive filter.

00:48:44.030 --> 00:48:45.760 align:middle line:84%
So you get this
kind of big pulse

00:48:45.760 --> 00:48:47.420 align:middle line:90%
of current and then nothing.

00:48:47.420 --> 00:48:51.610 align:middle line:84%
And then that internal
capacitor discharges.

00:48:51.610 --> 00:48:54.080 align:middle line:84%
So this leads to
terrible power factor.

00:48:54.080 --> 00:48:57.250 align:middle line:84%
And you can see that the power
factor is only about 0.53.

00:48:57.250 --> 00:49:01.900 align:middle line:84%
So what that says is if you
use lots of these bulbs,

00:49:01.900 --> 00:49:06.460 align:middle line:84%
you're kind of utilizing up
the capability of your source

00:49:06.460 --> 00:49:07.610 align:middle line:90%
to deliver power.

00:49:07.610 --> 00:49:10.450 align:middle line:84%
What that means is while
we're not measuring it here,

00:49:10.450 --> 00:49:13.330 align:middle line:84%
you're dissipating more power
back into the wall wiring

00:49:13.330 --> 00:49:14.740 align:middle line:90%
than you need to.

00:49:14.740 --> 00:49:18.190 align:middle line:84%
And in fact, if
you went and bought

00:49:18.190 --> 00:49:19.710 align:middle line:90%
one of the really new LED--

00:49:19.710 --> 00:49:22.290 align:middle line:90%


00:49:22.290 --> 00:49:27.210 align:middle line:84%
one of the really new
LED power supplies,

00:49:27.210 --> 00:49:29.340 align:middle line:84%
they might have a much
better power factor

00:49:29.340 --> 00:49:31.380 align:middle line:84%
because they're
being incentivized

00:49:31.380 --> 00:49:34.650 align:middle line:84%
if you want the Energy
Star stamp to do that.

00:49:34.650 --> 00:49:39.600 align:middle line:84%
Last example we'll
show you is one that

00:49:39.600 --> 00:49:40.900 align:middle line:90%
doesn't have a power converter.

00:49:40.900 --> 00:49:41.560 align:middle line:90%
This is a fan.

00:49:41.560 --> 00:49:45.285 align:middle line:90%
So this is a typical motor load.

00:49:45.285 --> 00:49:50.130 align:middle line:84%
And here you see the current
is reasonably sinusoidal,

00:49:50.130 --> 00:49:52.650 align:middle line:84%
but there's a phase
shift between the voltage

00:49:52.650 --> 00:49:53.380 align:middle line:90%
and the current.

00:49:53.380 --> 00:49:55.043 align:middle line:84%
The current lags
the voltage why?

00:49:55.043 --> 00:49:57.210 align:middle line:84%
Because it has to magnetize
the motor, and the motor

00:49:57.210 --> 00:49:59.500 align:middle line:84%
doesn't look like a
perfect resistive load.

00:49:59.500 --> 00:50:03.660 align:middle line:84%
So we get energy
transfer, and there's

00:50:03.660 --> 00:50:07.800 align:middle line:84%
a little bit of distortion
owing to the machine,

00:50:07.800 --> 00:50:09.090 align:middle line:90%
to the electric machine.

00:50:09.090 --> 00:50:11.680 align:middle line:84%
But nonetheless, it's
pretty close to sinusoidal.

00:50:11.680 --> 00:50:15.820 align:middle line:84%
But we only get about 0.7 power
factor because of this lag.

00:50:15.820 --> 00:50:17.910 align:middle line:84%
So people are
asking about, well,

00:50:17.910 --> 00:50:20.100 align:middle line:84%
what about if you're
a big industrial user?

00:50:20.100 --> 00:50:21.820 align:middle line:84%
A lot of big
industrial companies

00:50:21.820 --> 00:50:24.075 align:middle line:90%
have lots of motor loads.

00:50:24.075 --> 00:50:27.460 align:middle line:90%


00:50:27.460 --> 00:50:30.163 align:middle line:84%
They're using the pumps
and whatever have you

00:50:30.163 --> 00:50:30.830 align:middle line:90%
they're driving.

00:50:30.830 --> 00:50:34.940 align:middle line:84%
And that tends to generate
inductively loaded power factor.

00:50:34.940 --> 00:50:36.860 align:middle line:84%
So this isn't so much
the distortion factor.

00:50:36.860 --> 00:50:38.240 align:middle line:90%
This is displacement factor.

00:50:38.240 --> 00:50:40.730 align:middle line:84%
The interesting thing,
you can fix that one.

00:50:40.730 --> 00:50:44.530 align:middle line:84%
If I put some capacitor
in parallel with the line,

00:50:44.530 --> 00:50:46.910 align:middle line:90%
I could source.

00:50:46.910 --> 00:50:49.030 align:middle line:84%
I could kind of cancel
out the inductive element

00:50:49.030 --> 00:50:52.520 align:middle line:84%
and clean up my power factor
and make it very close to 1.

00:50:52.520 --> 00:50:54.910 align:middle line:84%
So if your problem
is phase shift,

00:50:54.910 --> 00:50:57.670 align:middle line:84%
you can fix it by adding
some reactants to the line

00:50:57.670 --> 00:51:00.100 align:middle line:90%
or susceptance to the line.

00:51:00.100 --> 00:51:02.830 align:middle line:84%
If your problem is because
you've got a crummy power

00:51:02.830 --> 00:51:05.170 align:middle line:84%
converter distorting things,
that's much harder to fix,

00:51:05.170 --> 00:51:07.540 align:middle line:84%
and you've got to fix your
power converter typically,

00:51:07.540 --> 00:51:09.940 align:middle line:84%
although there are
other tricks as well.

00:51:09.940 --> 00:51:13.000 align:middle line:84%
So that's about it for
today on power factor.

00:51:13.000 --> 00:51:15.285 align:middle line:84%
Are there any final
questions before we wrap up?

00:51:15.285 --> 00:51:18.350 align:middle line:90%


00:51:18.350 --> 00:51:19.190 align:middle line:90%
Yeah.

00:51:19.190 --> 00:51:21.465 align:middle line:84%
AUDIENCE: Is the power supply
coming from the outlet?

00:51:21.465 --> 00:51:22.590 align:middle line:90%
DAVID PERREAULT: I'm sorry?

00:51:22.590 --> 00:51:24.802 align:middle line:84%
AUDIENCE: Is the power supply
coming from the outlet?

00:51:24.802 --> 00:51:26.177 align:middle line:84%
DAVID PERREAULT:
Oh, is the power

00:51:26.177 --> 00:51:28.010 align:middle line:84%
that she was showing
coming from the outlet?

00:51:28.010 --> 00:51:28.585 align:middle line:90%
Yes, it was.

00:51:28.585 --> 00:51:31.680 align:middle line:84%
AUDIENCE: Is it commonplace
to not be beyond 20 volts?

00:51:31.680 --> 00:51:34.290 align:middle line:84%
DAVID PERREAULT: Ah, so
that's a very good question.

00:51:34.290 --> 00:51:38.150 align:middle line:84%
In this particular case,
we were running this

00:51:38.150 --> 00:51:40.790 align:middle line:84%
through a variac,
which lets us modulate

00:51:40.790 --> 00:51:42.120 align:middle line:90%
the voltage a little bit.

00:51:42.120 --> 00:51:48.200 align:middle line:84%
But the answer is, more broadly,
typical range of voltage

00:51:48.200 --> 00:51:51.712 align:middle line:84%
is minus 15% to plus
10% of the nominal.

00:51:51.712 --> 00:51:54.170 align:middle line:84%
And in fact, if you're going
to make a laptop power supply,

00:51:54.170 --> 00:51:56.990 align:middle line:84%
you've got to make it go down
way low because the line can

00:51:56.990 --> 00:51:58.010 align:middle line:90%
be all over the place.

00:51:58.010 --> 00:52:00.450 align:middle line:84%
The thing is, that's
pretty sinusoidal actually.

00:52:00.450 --> 00:52:02.780 align:middle line:84%
You'll often see it
often clips at the top

00:52:02.780 --> 00:52:07.580 align:middle line:84%
with very old-fashioned
peak clipping loads.

00:52:07.580 --> 00:52:10.190 align:middle line:84%
So you can get a lot of
distortion on your voltage too,

00:52:10.190 --> 00:52:12.000 align:middle line:84%
even though this is
pretty sinusoidal.

00:52:12.000 --> 00:52:17.270 align:middle line:84%
So yeah, it's not as accurate
as you might wish it to be.

00:52:17.270 --> 00:52:19.540 align:middle line:90%
All right, have a great day.

00:52:19.540 --> 00:52:23.000 align:middle line:90%