WEBVTT

00:00:00.000 --> 00:00:00.958 align:middle line:90%
JUDY HOYT: Get started.

00:00:00.958 --> 00:00:02.990 align:middle line:90%
Just a couple of reminders.

00:00:02.990 --> 00:00:05.870 align:middle line:84%
Homework number 4 is
due today up front.

00:00:05.870 --> 00:00:08.045 align:middle line:84%
You can bring that up
at the end of the hour.

00:00:08.045 --> 00:00:10.910 align:middle line:90%


00:00:10.910 --> 00:00:12.860 align:middle line:90%
Homework number 3 is going back.

00:00:12.860 --> 00:00:15.530 align:middle line:84%
I've got it in the back
there in that orange folder.

00:00:15.530 --> 00:00:20.065 align:middle line:84%
So you can pick up your
homework before you leave today.

00:00:20.065 --> 00:00:21.440 align:middle line:84%
And there are a
couple people who

00:00:21.440 --> 00:00:22.940 align:middle line:84%
haven't picked up
prior homework,

00:00:22.940 --> 00:00:26.330 align:middle line:84%
so they're in the back
of that orange folder.

00:00:26.330 --> 00:00:28.250 align:middle line:90%
We've got one handout for today.

00:00:28.250 --> 00:00:30.683 align:middle line:90%
That's handout 27.

00:00:30.683 --> 00:00:33.350 align:middle line:84%
Today we're going to be talking
about the SUPREM-IV four process

00:00:33.350 --> 00:00:34.280 align:middle line:90%
simulator.

00:00:34.280 --> 00:00:38.270 align:middle line:84%
This is where we are, November
2 here on election day.

00:00:38.270 --> 00:00:40.940 align:middle line:84%
And you're handing
in homework number 4.

00:00:40.940 --> 00:00:42.625 align:middle line:84%
The solutions to
homework number 3,

00:00:42.625 --> 00:00:44.750 align:middle line:84%
you're getting your graded
homework number 3s back.

00:00:44.750 --> 00:00:46.790 align:middle line:84%
The solutions will be
on the web later today,

00:00:46.790 --> 00:00:49.310 align:middle line:84%
and I'll bring hard
copies next time.

00:00:49.310 --> 00:00:54.810 align:middle line:84%
They didn't get printed
or xeroxed in time.

00:00:54.810 --> 00:00:58.560 align:middle line:84%
OK, so let's go on
to handout number

00:00:58.560 --> 00:01:01.560 align:middle line:84%
27, which is today's
handout for today's lecture.

00:01:01.560 --> 00:01:06.740 align:middle line:90%


00:01:06.740 --> 00:01:12.560 align:middle line:84%
This handout or this lecture
is on so-called quote unquote

00:01:12.560 --> 00:01:14.780 align:middle line:84%
"introduction to the
"SUPREM-IV process simulator."

00:01:14.780 --> 00:01:17.270 align:middle line:84%
Now, you've already really
been introduced to it.

00:01:17.270 --> 00:01:19.760 align:middle line:84%
Fortunately, you've
been using it

00:01:19.760 --> 00:01:22.430 align:middle line:84%
for the last couple of
homeworks in your homework sets.

00:01:22.430 --> 00:01:28.790 align:middle line:84%
And your TA introduced
it in a practical sense

00:01:28.790 --> 00:01:31.940 align:middle line:84%
a number of weeks ago when
she gave a lecture when you

00:01:31.940 --> 00:01:34.310 align:middle line:90%
had your first SUPREM homework.

00:01:34.310 --> 00:01:37.670 align:middle line:84%
But I want to talk about
it in a little more detail

00:01:37.670 --> 00:01:40.100 align:middle line:84%
and maybe give you
some examples of what

00:01:40.100 --> 00:01:42.065 align:middle line:90%
it can do, to give you an idea.

00:01:42.065 --> 00:01:44.600 align:middle line:90%


00:01:44.600 --> 00:01:48.170 align:middle line:84%
So in the very first lecture,
we discussed an example

00:01:48.170 --> 00:01:50.030 align:middle line:90%
of a CMOS process flow.

00:01:50.030 --> 00:01:52.490 align:middle line:84%
And we drew a
series of cartoons,

00:01:52.490 --> 00:01:57.740 align:middle line:84%
PowerPoint artist's conception
of what things would look like.

00:01:57.740 --> 00:02:01.130 align:middle line:84%
At this point in the class,
at this point in the class,

00:02:01.130 --> 00:02:03.260 align:middle line:84%
we've covered some
of the fundamentals

00:02:03.260 --> 00:02:07.320 align:middle line:84%
and the modeling of a lot of the
key processes in that CMOS flow.

00:02:07.320 --> 00:02:11.039 align:middle line:84%
We've talked about thermal
oxidation, diffusion of dopants.

00:02:11.039 --> 00:02:14.370 align:middle line:84%
We just had four lectures
on ion implantation

00:02:14.370 --> 00:02:16.080 align:middle line:90%
and transit-enhanced diffusion.

00:02:16.080 --> 00:02:17.940 align:middle line:84%
And we've talked a
little bit about how

00:02:17.940 --> 00:02:19.710 align:middle line:90%
these processes fit together.

00:02:19.710 --> 00:02:23.670 align:middle line:84%
So today I want to review
some of these concepts

00:02:23.670 --> 00:02:28.290 align:middle line:84%
and some CMOS process
modules and CMOS flows now

00:02:28.290 --> 00:02:31.140 align:middle line:84%
in the context of what
we know about models

00:02:31.140 --> 00:02:34.390 align:middle line:84%
and in the context of using
the SUPREM-IV simulator.

00:02:34.390 --> 00:02:39.540 align:middle line:84%
This is just an
example of an n MOSFET

00:02:39.540 --> 00:02:42.570 align:middle line:84%
and a p MOSFET
fabricated on a wafer.

00:02:42.570 --> 00:02:47.757 align:middle line:84%
This was the cartoon that we
showed earlier in this course,

00:02:47.757 --> 00:02:48.840 align:middle line:90%
in the very first lecture.

00:02:48.840 --> 00:02:50.340 align:middle line:84%
And what we can do
today is we don't

00:02:50.340 --> 00:02:51.600 align:middle line:90%
need to use cartoons anymore.

00:02:51.600 --> 00:02:53.700 align:middle line:84%
As you know, you can use
the SUPREM-IV simulator

00:02:53.700 --> 00:02:57.600 align:middle line:84%
to generate this type of
information reasonably

00:02:57.600 --> 00:02:59.650 align:middle line:90%
accurately.

00:02:59.650 --> 00:03:01.890 align:middle line:84%
So let's go on to
slide number 2.

00:03:01.890 --> 00:03:04.593 align:middle line:84%
And I have a series of examples
I wanted to go through.

00:03:04.593 --> 00:03:06.510 align:middle line:84%
And some of these things,
since you've already

00:03:06.510 --> 00:03:08.370 align:middle line:84%
run the simulator, you
may be familiar with.

00:03:08.370 --> 00:03:11.790 align:middle line:84%
But we'll go into some
things you may not have seen.

00:03:11.790 --> 00:03:13.477 align:middle line:90%
The first three are 1D.

00:03:13.477 --> 00:03:16.170 align:middle line:90%


00:03:16.170 --> 00:03:19.558 align:middle line:84%
SUPREM-IV, it's a
two-dimensional simulator.

00:03:19.558 --> 00:03:21.600 align:middle line:84%
But it can be run in a
one-dimensional mode where

00:03:21.600 --> 00:03:25.540 align:middle line:84%
you're primarily interested
in what happens in depth.

00:03:25.540 --> 00:03:27.770 align:middle line:84%
But in general, you
run it in 2D mode.

00:03:27.770 --> 00:03:30.730 align:middle line:84%
But to run things quickly,
to understand basic physics

00:03:30.730 --> 00:03:34.630 align:middle line:84%
concepts, it's often easier to
run the simulator in 1D mode

00:03:34.630 --> 00:03:37.780 align:middle line:84%
and then later on run a
two-dimensional example.

00:03:37.780 --> 00:03:39.700 align:middle line:84%
Obviously, when you
do it in 2D mode

00:03:39.700 --> 00:03:43.400 align:middle line:84%
you have a lot more calculations
to do and it's a lot slower.

00:03:43.400 --> 00:03:45.460 align:middle line:84%
So first, I want to talk
a little bit about boron

00:03:45.460 --> 00:03:48.400 align:middle line:84%
segregation at a gate
oxide silicon interface

00:03:48.400 --> 00:03:49.960 align:middle line:90%
and compare a couple issues.

00:03:49.960 --> 00:03:52.240 align:middle line:84%
And I'm using this
as an example for you

00:03:52.240 --> 00:03:53.950 align:middle line:84%
to understand a little
bit about gridding

00:03:53.950 --> 00:03:56.200 align:middle line:84%
issues that can take place
when you use the simulator.

00:03:56.200 --> 00:04:03.100 align:middle line:84%
So a very practical issue of
keeping an eye on how fine

00:04:03.100 --> 00:04:05.040 align:middle line:90%
your grid is.

00:04:05.040 --> 00:04:08.640 align:middle line:84%
The second example, we'll talk
about comparing some arsenic

00:04:08.640 --> 00:04:13.050 align:middle line:84%
and phosphorus implant profiles,
the different types of profiles,

00:04:13.050 --> 00:04:14.700 align:middle line:90%
to actual SIMS data.

00:04:14.700 --> 00:04:17.190 align:middle line:84%
We'll see which
ones do a better job

00:04:17.190 --> 00:04:21.060 align:middle line:84%
at actually simulating
or reproducing

00:04:21.060 --> 00:04:22.170 align:middle line:90%
what the data looks like.

00:04:22.170 --> 00:04:25.080 align:middle line:84%
And then we'll talk
about diffusion models,

00:04:25.080 --> 00:04:28.520 align:middle line:84%
introduce the different
types of diffusion models

00:04:28.520 --> 00:04:29.950 align:middle line:90%
that are available.

00:04:29.950 --> 00:04:32.250 align:middle line:90%
And again, these three are 1D.

00:04:32.250 --> 00:04:34.080 align:middle line:84%
The last example-- I
hope we have time--

00:04:34.080 --> 00:04:38.280 align:middle line:84%
is 2D example of an
older technology.

00:04:38.280 --> 00:04:41.010 align:middle line:84%
It's a 200-nanometer
gate length n

00:04:41.010 --> 00:04:48.000 align:middle line:84%
MOSFET just to go through some
of the processing of that.

00:04:48.000 --> 00:04:49.700 align:middle line:84%
So let's go on to
slide number 3.

00:04:49.700 --> 00:04:52.100 align:middle line:84%
This is an example,
and if you've already

00:04:52.100 --> 00:04:54.525 align:middle line:84%
done the homeworks,
you've probably seen this.

00:04:54.525 --> 00:04:58.220 align:middle line:84%
This is an example of what's
called the mesh or the grid.

00:04:58.220 --> 00:05:04.250 align:middle line:84%
And SUPREM-IV uses a triangular
grid, triangular mesh.

00:05:04.250 --> 00:05:07.470 align:middle line:84%
So it's a series of
nonoverlapping triangular

00:05:07.470 --> 00:05:07.970 align:middle line:90%
elements.

00:05:07.970 --> 00:05:09.053 align:middle line:90%
You see each one of these.

00:05:09.053 --> 00:05:14.830 align:middle line:84%
If you look at it carefully,
it can be drawn as a triangle.

00:05:14.830 --> 00:05:18.850 align:middle line:84%
The mesh is very
important because what

00:05:18.850 --> 00:05:21.220 align:middle line:84%
we do in the mesh or
the grid is that we--

00:05:21.220 --> 00:05:24.010 align:middle line:84%
to frame four tracks, the
values of all parameters

00:05:24.010 --> 00:05:28.210 align:middle line:84%
numerically along a
moving adjustable grid.

00:05:28.210 --> 00:05:31.180 align:middle line:84%
So at these nodes,
at these grid points

00:05:31.180 --> 00:05:34.840 align:middle line:84%
is tracking the values of
all-important parameters,

00:05:34.840 --> 00:05:38.620 align:middle line:84%
the interface-- what the
material is, the interface

00:05:38.620 --> 00:05:39.820 align:middle line:90%
between two materials.

00:05:39.820 --> 00:05:43.420 align:middle line:84%
It tracks the dopant
concentration value.

00:05:43.420 --> 00:05:47.985 align:middle line:84%
A lot of different things are
tracked at each grid point.

00:05:47.985 --> 00:05:49.360 align:middle line:84%
If you look at
this grid, so this

00:05:49.360 --> 00:05:52.100 align:middle line:84%
is a grid that belongs
to a device structure.

00:05:52.100 --> 00:05:54.920 align:middle line:84%
Let me see if I have
in the next slide.

00:05:54.920 --> 00:05:55.930 align:middle line:90%
Oh, that's a blow up.

00:05:55.930 --> 00:05:58.900 align:middle line:84%
Yeah, let's just go a little bit
of a blow up on slide number 4.

00:05:58.900 --> 00:06:01.270 align:middle line:84%
You can see the grid
a little bit better.

00:06:01.270 --> 00:06:03.310 align:middle line:84%
This belongs to a
device structure

00:06:03.310 --> 00:06:07.160 align:middle line:84%
where over here on the left-hand
side there's actually a gate.

00:06:07.160 --> 00:06:08.303 align:middle line:90%
There's a polysilicon gate.

00:06:08.303 --> 00:06:09.220 align:middle line:90%
There's a space there.

00:06:09.220 --> 00:06:09.790 align:middle line:90%
I don't know if you can see.

00:06:09.790 --> 00:06:11.020 align:middle line:90%
Here's a gate oxide.

00:06:11.020 --> 00:06:12.760 align:middle line:90%
And there's some metal up here.

00:06:12.760 --> 00:06:15.060 align:middle line:90%
And this is the silicon.

00:06:15.060 --> 00:06:17.240 align:middle line:84%
This is an ion implanted
and diffused junction.

00:06:17.240 --> 00:06:20.683 align:middle line:84%
And you say, why does the
grid look like it does?

00:06:20.683 --> 00:06:21.850 align:middle line:90%
Why would it look like this?

00:06:21.850 --> 00:06:22.350 align:middle line:90%
You see?

00:06:22.350 --> 00:06:26.960 align:middle line:84%
In this region here, near the
channel and near the surface,

00:06:26.960 --> 00:06:28.720 align:middle line:90%
you see a very fine grid.

00:06:28.720 --> 00:06:31.270 align:middle line:90%
The mesh is very fine.

00:06:31.270 --> 00:06:33.620 align:middle line:84%
The spacing between the
grid points is very small.

00:06:33.620 --> 00:06:35.860 align:middle line:84%
Whereas, you get down here
in the silicon substrate,

00:06:35.860 --> 00:06:37.630 align:middle line:90%
and the mesh is very coarse.

00:06:37.630 --> 00:06:40.720 align:middle line:84%
The spacing between points
on which you do the solution

00:06:40.720 --> 00:06:42.430 align:middle line:90%
is very large.

00:06:42.430 --> 00:06:43.870 align:middle line:90%
So why would that be?

00:06:43.870 --> 00:06:47.000 align:middle line:84%
Does anybody have any
idea why up here I

00:06:47.000 --> 00:06:50.338 align:middle line:84%
would have a fine grid, and
down here I have a coarse grid?

00:06:50.338 --> 00:06:52.630 align:middle line:84%
AUDIENCE: Because the term--
does this change anything?

00:06:52.630 --> 00:06:55.570 align:middle line:84%
JUDY HOYT: Right, because
up here at the junction

00:06:55.570 --> 00:06:57.820 align:middle line:84%
you probably have some
doping profiles that are

00:06:57.820 --> 00:06:59.440 align:middle line:90%
changing very rapidly in depth.

00:06:59.440 --> 00:07:01.900 align:middle line:84%
So you need a lot of
grid points to maintain

00:07:01.900 --> 00:07:07.150 align:middle line:84%
good accuracy and good fidelity
in reproducing those profiles.

00:07:07.150 --> 00:07:08.980 align:middle line:84%
Down here, there's
really not much action.

00:07:08.980 --> 00:07:11.240 align:middle line:84%
Probably just constant
doping of boron.

00:07:11.240 --> 00:07:14.320 align:middle line:84%
So there's no need to
have very fine mesh.

00:07:14.320 --> 00:07:16.640 align:middle line:84%
Even today's computers
are only so powerful.

00:07:16.640 --> 00:07:19.030 align:middle line:84%
So SUPREM tries to do
intelligent gridding

00:07:19.030 --> 00:07:20.910 align:middle line:84%
and not waste and put
in a lot of grid points

00:07:20.910 --> 00:07:21.910 align:middle line:90%
where you don't need it.

00:07:21.910 --> 00:07:23.663 align:middle line:84%
If you use a very
fine mesh everywhere,

00:07:23.663 --> 00:07:25.330 align:middle line:84%
you'd say, well,
that's the best, right?

00:07:25.330 --> 00:07:26.500 align:middle line:90%
Make it fine everywhere.

00:07:26.500 --> 00:07:29.650 align:middle line:84%
The problem with that is
it would take too long

00:07:29.650 --> 00:07:33.970 align:middle line:84%
to the solution, and it's
really a waste of time.

00:07:33.970 --> 00:07:35.452 align:middle line:84%
So just going back
to slide 3, this

00:07:35.452 --> 00:07:36.660 align:middle line:90%
is exactly what we just said.

00:07:36.660 --> 00:07:39.390 align:middle line:84%
The grid needs to be fine
near the active device region,

00:07:39.390 --> 00:07:42.750 align:middle line:84%
near the interface, or where
any quantity of interest

00:07:42.750 --> 00:07:44.700 align:middle line:84%
is changing very
rapidly, depending

00:07:44.700 --> 00:07:47.640 align:middle line:84%
on what you're interested in
knowing about, doping profiles,

00:07:47.640 --> 00:07:49.230 align:middle line:90%
interstitials, vacancies.

00:07:49.230 --> 00:07:54.720 align:middle line:84%
Wherever they change rapidly,
you need a fine grid.

00:07:54.720 --> 00:07:58.740 align:middle line:84%
For diffusion, very often
SUPREM does a finite difference

00:07:58.740 --> 00:08:00.390 align:middle line:90%
solution for oxidation.

00:08:00.390 --> 00:08:03.670 align:middle line:84%
It uses a finite element
type of technique, again,

00:08:03.670 --> 00:08:04.770 align:middle line:90%
both on this grid.

00:08:04.770 --> 00:08:07.440 align:middle line:90%


00:08:07.440 --> 00:08:09.690 align:middle line:84%
OK, let's go on
to slide number 5.

00:08:09.690 --> 00:08:12.960 align:middle line:84%
Actually, I probably should
have shown this first.

00:08:12.960 --> 00:08:15.570 align:middle line:84%
Of that mesh that
we just showed,

00:08:15.570 --> 00:08:17.790 align:middle line:84%
this is the actual
device structure.

00:08:17.790 --> 00:08:19.920 align:middle line:90%
It's half of an n MOSFET.

00:08:19.920 --> 00:08:21.660 align:middle line:84%
And now it becomes
pretty obvious

00:08:21.660 --> 00:08:23.577 align:middle line:84%
what you were looking
at in terms of the grid.

00:08:23.577 --> 00:08:25.090 align:middle line:90%
The yellow here is the silicon.

00:08:25.090 --> 00:08:28.340 align:middle line:90%
This is the polysilicon gate.

00:08:28.340 --> 00:08:30.030 align:middle line:90%
The blue is the gate oxide.

00:08:30.030 --> 00:08:33.409 align:middle line:84%
This is an oxide a
spacer, a sidewall spacer

00:08:33.409 --> 00:08:34.669 align:middle line:90%
right next to it.

00:08:34.669 --> 00:08:37.370 align:middle line:84%
There's a metal contact
here to the silicon.

00:08:37.370 --> 00:08:41.690 align:middle line:84%
And this is the sort of LOCOS
region, or the isolation region,

00:08:41.690 --> 00:08:42.919 align:middle line:90%
in between devices.

00:08:42.919 --> 00:08:45.080 align:middle line:84%
This is either the
source or the drain,

00:08:45.080 --> 00:08:49.440 align:middle line:84%
and you can see contours here
corresponding to arsenic doping.

00:08:49.440 --> 00:08:51.830 align:middle line:90%
So this is the actual structure.

00:08:51.830 --> 00:08:55.280 align:middle line:84%
Very often, in SUPREM,
things are symmetrical.

00:08:55.280 --> 00:08:58.520 align:middle line:84%
So another way, besides
doing intelligent gridding,

00:08:58.520 --> 00:09:00.110 align:middle line:84%
if you have a
symmetrical device,

00:09:00.110 --> 00:09:02.840 align:middle line:84%
you can often only simulate
half of it and then just

00:09:02.840 --> 00:09:06.290 align:middle line:84%
project that about
the center line

00:09:06.290 --> 00:09:10.400 align:middle line:84%
here because the MOSFETs
are very often symmetrical

00:09:10.400 --> 00:09:11.900 align:middle line:90%
in the way they're fabricated.

00:09:11.900 --> 00:09:15.780 align:middle line:84%
So sometimes that helps you
save time in the simulation.

00:09:15.780 --> 00:09:17.060 align:middle line:90%
So again, once you start--

00:09:17.060 --> 00:09:19.868 align:middle line:84%
we haven't had do very many
two-dimensional simulations.

00:09:19.868 --> 00:09:21.410 align:middle line:84%
But once you start
doing them, you'll

00:09:21.410 --> 00:09:25.520 align:middle line:84%
see how much time it can take
to simulate all these diffusion,

00:09:25.520 --> 00:09:27.960 align:middle line:84%
especially if you're doing
the most sophisticated models.

00:09:27.960 --> 00:09:31.605 align:middle line:84%
So you have to take advantage
of intelligent gridding.

00:09:31.605 --> 00:09:34.490 align:middle line:90%


00:09:34.490 --> 00:09:37.100 align:middle line:84%
I want to start
on slide number 6

00:09:37.100 --> 00:09:42.380 align:middle line:84%
the first example now, which is
a simple one-dimensional example

00:09:42.380 --> 00:09:44.480 align:middle line:84%
that looks at the
behavior of boron

00:09:44.480 --> 00:09:46.610 align:middle line:84%
and how it behaves
and segregates

00:09:46.610 --> 00:09:49.040 align:middle line:90%
at an oxide silicon interface.

00:09:49.040 --> 00:09:52.200 align:middle line:84%
And this is a
SUPREM-IV input file.

00:09:52.200 --> 00:09:54.200 align:middle line:84%
As you know, all of you
have done your homework,

00:09:54.200 --> 00:09:57.410 align:middle line:84%
SUPREM-IV takes
text files as input.

00:09:57.410 --> 00:09:59.150 align:middle line:84%
You can write the text
in any text editor

00:09:59.150 --> 00:10:00.650 align:middle line:84%
you want as long
as it doesn't leave

00:10:00.650 --> 00:10:03.890 align:middle line:84%
a lot of spurious characters
that confuse the program.

00:10:03.890 --> 00:10:06.980 align:middle line:84%
And the program has a parser
that reads in the text

00:10:06.980 --> 00:10:09.650 align:middle line:84%
and interprets the text
in terms of the commands

00:10:09.650 --> 00:10:12.850 align:middle line:90%
that SUPREM-IV knows about.

00:10:12.850 --> 00:10:14.600 align:middle line:84%
Whenever you see a
dollar sign, of course,

00:10:14.600 --> 00:10:15.650 align:middle line:90%
that's just a comment.

00:10:15.650 --> 00:10:16.980 align:middle line:90%
So SUPREM ignores that.

00:10:16.980 --> 00:10:19.730 align:middle line:84%
So this is only for
your own notation.

00:10:19.730 --> 00:10:23.660 align:middle line:84%
So the first command here
is called the mesh command,

00:10:23.660 --> 00:10:25.970 align:middle line:84%
and it tells you that
a parameter called

00:10:25.970 --> 00:10:28.580 align:middle line:90%
grid dot fac equals 0.04.

00:10:28.580 --> 00:10:30.090 align:middle line:84%
And then the grid
factor has to do

00:10:30.090 --> 00:10:31.340 align:middle line:90%
with the fineness of the grid.

00:10:31.340 --> 00:10:35.260 align:middle line:84%
The smaller the number,
the finer the mesh.

00:10:35.260 --> 00:10:39.480 align:middle line:84%
And so we're defining
in this one statement

00:10:39.480 --> 00:10:44.940 align:middle line:84%
what we want to make the default
mesh size in a uniform sense.

00:10:44.940 --> 00:10:46.890 align:middle line:90%
AUDIENCE: [INAUDIBLE].

00:10:46.890 --> 00:10:49.920 align:middle line:84%
JUDY HOYT: 0.04,
it's not in units.

00:10:49.920 --> 00:10:51.730 align:middle line:90%
I think it's a multiplier.

00:10:51.730 --> 00:10:57.300 align:middle line:84%
So I think it can be anything
from 1 to 10 to maybe 0.01.

00:10:57.300 --> 00:10:59.550 align:middle line:84%
If you look up in the SUPREM
manual, it will tell you.

00:10:59.550 --> 00:11:02.130 align:middle line:84%
I don't remember the exact
definition of grid dot fact,

00:11:02.130 --> 00:11:06.300 align:middle line:84%
but when grid dot fac
equals 1, it gives you

00:11:06.300 --> 00:11:07.680 align:middle line:90%
a certain grid spacing.

00:11:07.680 --> 00:11:10.080 align:middle line:84%
My experience has been that,
for most modern devices,

00:11:10.080 --> 00:11:13.140 align:middle line:84%
a grid dot fac of 1, it's
a pretty large spacing,

00:11:13.140 --> 00:11:15.943 align:middle line:84%
larger than we would
probably want to have.

00:11:15.943 --> 00:11:18.360 align:middle line:84%
I think I have some examples
where we varied this in here,

00:11:18.360 --> 00:11:20.460 align:middle line:84%
so we can look for the
different grid dot facs.

00:11:20.460 --> 00:11:23.040 align:middle line:90%
And you'll see how it comes out.

00:11:23.040 --> 00:11:24.712 align:middle line:90%
The next thing is pretty simple.

00:11:24.712 --> 00:11:26.670 align:middle line:84%
It says an initialize
statement, this says just

00:11:26.670 --> 00:11:27.930 align:middle line:90%
create the silicon substrate.

00:11:27.930 --> 00:11:28.810 align:middle line:90%
That's all it does.

00:11:28.810 --> 00:11:32.800 align:middle line:84%
It tells you the orientation
in the z-axis is 100.

00:11:32.800 --> 00:11:35.250 align:middle line:84%
So that's the
orientation of the wafer.

00:11:35.250 --> 00:11:39.690 align:middle line:84%
And it's boron doped, and it's
1E17 per cubic centimeter.

00:11:39.690 --> 00:11:43.320 align:middle line:84%
And again, if you need to know
things like boron equals 1E17,

00:11:43.320 --> 00:11:45.990 align:middle line:84%
you wonder what the units are,
if you go into the SUPREM-IV

00:11:45.990 --> 00:11:48.480 align:middle line:84%
manual, it'll tell
you what the default

00:11:48.480 --> 00:11:51.430 align:middle line:90%
units are for any variable.

00:11:51.430 --> 00:11:52.680 align:middle line:90%
This is an implant statement.

00:11:52.680 --> 00:11:56.400 align:middle line:84%
You just did a homework
on ion implantation,

00:11:56.400 --> 00:11:58.300 align:middle line:90%
where we're implanting boron.

00:11:58.300 --> 00:11:59.370 align:middle line:90%
So this is the species.

00:11:59.370 --> 00:12:02.050 align:middle line:84%
This is the dose, the number
of atoms per square centimeter,

00:12:02.050 --> 00:12:03.270 align:middle line:90%
the energy.

00:12:03.270 --> 00:12:07.540 align:middle line:84%
And you're specifying a
tilt angle of seven degrees.

00:12:07.540 --> 00:12:09.150 align:middle line:84%
Depending on the
dopants, there will

00:12:09.150 --> 00:12:11.800 align:middle line:90%
be different default models.

00:12:11.800 --> 00:12:14.885 align:middle line:84%
A lot of the dopants default
to the Pearson-IV model.

00:12:14.885 --> 00:12:17.010 align:middle line:84%
In other words, if you
don't say what model to use,

00:12:17.010 --> 00:12:19.590 align:middle line:84%
it automatically uses
default Pearson-IV.

00:12:19.590 --> 00:12:22.650 align:middle line:84%
I think arsenic defaults
to dual Pearson.

00:12:22.650 --> 00:12:24.330 align:middle line:84%
You have to look up
in the SUPREM manual

00:12:24.330 --> 00:12:27.640 align:middle line:84%
and figure out what the default
is if you don't specify.

00:12:27.640 --> 00:12:29.950 align:middle line:84%
So remember, just because
you didn't say a model,

00:12:29.950 --> 00:12:32.150 align:middle line:84%
SUPREM has to assume
one of the models.

00:12:32.150 --> 00:12:33.500 align:middle line:90%
And so that's the default model.

00:12:33.500 --> 00:12:35.417 align:middle line:84%
You need to become
familiar with what that is.

00:12:35.417 --> 00:12:37.960 align:middle line:90%


00:12:37.960 --> 00:12:39.983 align:middle line:90%
This statement here is deposing.

00:12:39.983 --> 00:12:41.150 align:middle line:90%
It's a deposition statement.

00:12:41.150 --> 00:12:42.580 align:middle line:90%
So it's not a growth.

00:12:42.580 --> 00:12:44.050 align:middle line:90%
It's not thermal oxidation.

00:12:44.050 --> 00:12:48.220 align:middle line:84%
It's literally depositing oxide
just by plunking it, (WHIT),

00:12:48.220 --> 00:12:48.940 align:middle line:90%
on the surface.

00:12:48.940 --> 00:12:50.410 align:middle line:84%
You're not consuming
any silicon.

00:12:50.410 --> 00:12:53.170 align:middle line:84%
And we haven't talked about
this type of process before,

00:12:53.170 --> 00:12:55.060 align:middle line:84%
but it's called chemical
vapor deposition.

00:12:55.060 --> 00:12:57.195 align:middle line:84%
The next several lectures
we'll talk about that.

00:12:57.195 --> 00:12:58.570 align:middle line:84%
So this is not
thermal oxidation.

00:12:58.570 --> 00:13:00.550 align:middle line:84%
We're just plunking
an oxide down

00:13:00.550 --> 00:13:03.243 align:middle line:90%
at a certain temperature, 600.

00:13:03.243 --> 00:13:04.660 align:middle line:84%
And we're telling
it the thickness

00:13:04.660 --> 00:13:08.150 align:middle line:90%
in microns, 0.005 microns.

00:13:08.150 --> 00:13:08.950 align:middle line:90%
So it's very thin.

00:13:08.950 --> 00:13:10.330 align:middle line:90%
It's 50 angstroms.

00:13:10.330 --> 00:13:14.460 align:middle line:84%
DY, if you look in
the SUPREM manual

00:13:14.460 --> 00:13:16.800 align:middle line:84%
under the deposition
statement for oxide,

00:13:16.800 --> 00:13:21.330 align:middle line:84%
DY tells the grid spacing
in the y direction

00:13:21.330 --> 00:13:23.110 align:middle line:84%
that you want to
use in the oxide.

00:13:23.110 --> 00:13:26.610 align:middle line:84%
So DY is the grid spacing
specific to the oxide.

00:13:26.610 --> 00:13:27.990 align:middle line:90%
And look how small it is.

00:13:27.990 --> 00:13:30.450 align:middle line:90%
It's 0.0001.

00:13:30.450 --> 00:13:33.030 align:middle line:84%
Well, the reason it's so
small is because the thickness

00:13:33.030 --> 00:13:34.120 align:middle line:90%
is so small.

00:13:34.120 --> 00:13:36.000 align:middle line:84%
You don't want one grid
point in the oxide.

00:13:36.000 --> 00:13:37.140 align:middle line:90%
You'd like to have several.

00:13:37.140 --> 00:13:39.720 align:middle line:84%
So we're telling it what
the gridding to use just

00:13:39.720 --> 00:13:42.090 align:middle line:90%
in the oxide.

00:13:42.090 --> 00:13:44.010 align:middle line:84%
And then there's
a simple statement

00:13:44.010 --> 00:13:46.170 align:middle line:84%
in which you select what
variable you want to plot.

00:13:46.170 --> 00:13:48.840 align:middle line:84%
In this case, you want to
plot the log10 of boron.

00:13:48.840 --> 00:13:50.640 align:middle line:90%
You can do some fancy--

00:13:50.640 --> 00:13:53.980 align:middle line:84%
put in titles and
all that stuff.

00:13:53.980 --> 00:13:58.450 align:middle line:84%
The Save File command
saves the file in a format

00:13:58.450 --> 00:14:01.987 align:middle line:84%
that SUPREM can then later
use, read in and use later on.

00:14:01.987 --> 00:14:04.570 align:middle line:84%
It's not necessarily a format
that you would find very useful.

00:14:04.570 --> 00:14:06.070 align:middle line:90%
But SUPREM uses it.

00:14:06.070 --> 00:14:09.790 align:middle line:84%
So Save File into
an out dot file is--

00:14:09.790 --> 00:14:11.680 align:middle line:84%
defines which file you
want it to write to.

00:14:11.680 --> 00:14:14.860 align:middle line:84%
And this is the particular
name we chose, B1 dot inp.

00:14:14.860 --> 00:14:17.470 align:middle line:84%
You can put it
wherever you want.

00:14:17.470 --> 00:14:20.890 align:middle line:84%
Here, you're simulating
the diffusion.

00:14:20.890 --> 00:14:26.850 align:middle line:84%
So this is simulating diffusion
for a time of 17 minutes

00:14:26.850 --> 00:14:28.440 align:middle line:90%
at a temperature of 850.

00:14:28.440 --> 00:14:30.930 align:middle line:84%
And if I specify
an inner ambient,

00:14:30.930 --> 00:14:33.870 align:middle line:84%
it's just like a diffusion,
like an argon or nitrogen.

00:14:33.870 --> 00:14:38.160 align:middle line:84%
If I specify dry O2, then you're
actually doing an oxidizing.

00:14:38.160 --> 00:14:41.400 align:middle line:84%
So oxidation is done,
as you know now,

00:14:41.400 --> 00:14:43.920 align:middle line:84%
by using the diffusion
statement and specifying

00:14:43.920 --> 00:14:47.550 align:middle line:84%
what type of [? ambient ?]----
wet O2, dry O2, whichever.

00:14:47.550 --> 00:14:53.160 align:middle line:84%
And then, after this amount of
diffusion, 850 for 17 minutes,

00:14:53.160 --> 00:14:55.080 align:middle line:84%
you're going to plot
what the profile looks

00:14:55.080 --> 00:14:56.530 align:middle line:90%
like of the boron after that.

00:14:56.530 --> 00:14:59.800 align:middle line:90%
So we have an as-implanted plot.

00:14:59.800 --> 00:15:03.480 align:middle line:84%
And we have a certain line type
and color, here, color number

00:15:03.480 --> 00:15:04.080 align:middle line:90%
one.

00:15:04.080 --> 00:15:08.880 align:middle line:84%
And we have after diffusion
at 17 minutes at 850.

00:15:08.880 --> 00:15:10.080 align:middle line:90%
This is a simple file.

00:15:10.080 --> 00:15:12.912 align:middle line:84%
It's a type of file that you've
been using that your TAs been

00:15:12.912 --> 00:15:13.620 align:middle line:90%
creating for you.

00:15:13.620 --> 00:15:14.370 align:middle line:90%
And you've been running them.

00:15:14.370 --> 00:15:15.600 align:middle line:84%
Now we want you to
start to understand

00:15:15.600 --> 00:15:18.150 align:middle line:84%
what those files do so you can
create them and modify them

00:15:18.150 --> 00:15:19.638 align:middle line:90%
yourself.

00:15:19.638 --> 00:15:21.930 align:middle line:84%
And remember, you can always
go to the SUPREM-IV manual

00:15:21.930 --> 00:15:24.360 align:middle line:84%
to look up any of these
commands, deposition,

00:15:24.360 --> 00:15:25.920 align:middle line:90%
select, Save file.

00:15:25.920 --> 00:15:28.120 align:middle line:84%
All those are explained
in the manual.

00:15:28.120 --> 00:15:31.950 align:middle line:84%
So this is the output of
that file on slide number 7.

00:15:31.950 --> 00:15:33.300 align:middle line:90%
This is what it looks like.

00:15:33.300 --> 00:15:34.920 align:middle line:90%
Of course, I've doctored it up.

00:15:34.920 --> 00:15:36.870 align:middle line:84%
I've added a little
color and things

00:15:36.870 --> 00:15:40.470 align:middle line:84%
to make it look a little better,
but it's the basic output.

00:15:40.470 --> 00:15:42.540 align:middle line:84%
What that file
puts out is a plot.

00:15:42.540 --> 00:15:45.750 align:middle line:84%
On the y-axis is the
boron concentration.

00:15:45.750 --> 00:15:48.090 align:middle line:90%
The x-axis is distance.

00:15:48.090 --> 00:15:50.820 align:middle line:90%
And SUPREM assumes that 0--

00:15:50.820 --> 00:15:54.750 align:middle line:84%
it puts 0 at the original
silicon interface, or surface,

00:15:54.750 --> 00:15:55.510 align:middle line:90%
I should say.

00:15:55.510 --> 00:15:58.770 align:middle line:84%
So if you deposit
layers on top of that,

00:15:58.770 --> 00:16:02.020 align:middle line:84%
they will be sort of
on the negative x-axis.

00:16:02.020 --> 00:16:04.500 align:middle line:84%
Remember, we deposited
50 angstroms of oxide.

00:16:04.500 --> 00:16:06.330 align:middle line:84%
That's what I'm showing
in the yellow here.

00:16:06.330 --> 00:16:09.360 align:middle line:84%
If you go back one minute and
you look at deposition oxide,

00:16:09.360 --> 00:16:12.180 align:middle line:90%
thickness is 0.005 microns.

00:16:12.180 --> 00:16:14.770 align:middle line:90%
That's 50 angstroms.

00:16:14.770 --> 00:16:16.980 align:middle line:84%
So that's what
this is, from here

00:16:16.980 --> 00:16:18.970 align:middle line:90%
to here in this yellow region.

00:16:18.970 --> 00:16:23.300 align:middle line:84%
And there are two profiles
that are shown here.

00:16:23.300 --> 00:16:26.580 align:middle line:84%
The black one, the
dark one is SUPREM

00:16:26.580 --> 00:16:28.290 align:middle line:84%
plotted the boron
profile immediately

00:16:28.290 --> 00:16:30.190 align:middle line:90%
after ion implantation.

00:16:30.190 --> 00:16:32.730 align:middle line:90%
So that's the as-implanted.

00:16:32.730 --> 00:16:37.470 align:middle line:84%
And the red one is the boron
profile after that anneal

00:16:37.470 --> 00:16:40.780 align:middle line:84%
that we did, 17
minutes inert at 850.

00:16:40.780 --> 00:16:41.980 align:middle line:90%
Of course, it's diffused.

00:16:41.980 --> 00:16:43.510 align:middle line:90%
The peak has gone down a little.

00:16:43.510 --> 00:16:44.750 align:middle line:90%
It's broadened out.

00:16:44.750 --> 00:16:47.410 align:middle line:84%
And there has been a
little bit of segregation

00:16:47.410 --> 00:16:51.280 align:middle line:90%
at the oxide silicon interface.

00:16:51.280 --> 00:16:54.070 align:middle line:84%
The diffusion of boron and
oxide is relatively slow.

00:16:54.070 --> 00:16:57.550 align:middle line:84%
It's about a factor of 2,000,
roughly, a factor of 1,000

00:16:57.550 --> 00:16:59.380 align:middle line:84%
slower than
diffusion in silicon.

00:16:59.380 --> 00:17:02.020 align:middle line:84%
So you see a fair amount of
motion of the boron and silicon.

00:17:02.020 --> 00:17:04.119 align:middle line:84%
But when it hits that
wall, hits that oxide,

00:17:04.119 --> 00:17:05.990 align:middle line:90%
it doesn't diffuse very fast.

00:17:05.990 --> 00:17:08.200 align:middle line:84%
So you're not going
to get-- you see

00:17:08.200 --> 00:17:12.099 align:middle line:84%
in the silicon there's very
little boron after 17 minutes

00:17:12.099 --> 00:17:15.079 align:middle line:90%
has actually diffused in.

00:17:15.079 --> 00:17:17.190 align:middle line:84%
If you want to know the
segregation coefficient,

00:17:17.190 --> 00:17:18.890 align:middle line:84%
you can look it up
in the appendix.

00:17:18.890 --> 00:17:20.599 align:middle line:84%
They have an
appendix in SUPREM-IV

00:17:20.599 --> 00:17:22.579 align:middle line:90%
for each of the dopants.

00:17:22.579 --> 00:17:25.250 align:middle line:84%
For boron segregation,
which is the ratio

00:17:25.250 --> 00:17:27.829 align:middle line:84%
of the concentration of
boron in the silicon to that

00:17:27.829 --> 00:17:29.540 align:middle line:90%
in the oxide at 850.

00:17:29.540 --> 00:17:32.125 align:middle line:84%
SUPREM calculates it
from this formula.

00:17:32.125 --> 00:17:34.500 align:middle line:84%
You can modify either one of
these constants, by the way,

00:17:34.500 --> 00:17:35.300 align:middle line:90%
if you want to.

00:17:35.300 --> 00:17:40.460 align:middle line:84%
And I calculate it at about
a factor of 10 to 1, or 0.1.

00:17:40.460 --> 00:17:45.670 align:middle line:84%
So that would be this peak
value to the value in the oxide.

00:17:45.670 --> 00:17:47.980 align:middle line:84%
So that's what that
simple file puts out.

00:17:47.980 --> 00:17:52.730 align:middle line:84%
Now, let's look at a couple
of other special cases.

00:17:52.730 --> 00:17:55.480 align:middle line:84%
So we're going to now
do something similar.

00:17:55.480 --> 00:17:57.580 align:middle line:84%
But instead of depositing
the oxide straight

00:17:57.580 --> 00:18:01.630 align:middle line:84%
down by deposition, from
chemical vapor deposition,

00:18:01.630 --> 00:18:04.810 align:middle line:84%
we're going to form the
oxide by thermal oxidation.

00:18:04.810 --> 00:18:07.750 align:middle line:84%
This is the type of model that
we've talked about before.

00:18:07.750 --> 00:18:09.520 align:middle line:84%
And we're going to
display the output.

00:18:09.520 --> 00:18:15.160 align:middle line:84%
Here on slide number 8, I'm
showing a new SUPREM input

00:18:15.160 --> 00:18:17.360 align:middle line:90%
file, or command file.

00:18:17.360 --> 00:18:19.360 align:middle line:84%
And this time, instead
of saying deposition,

00:18:19.360 --> 00:18:21.310 align:middle line:84%
we're going to say
to do a diffusion.

00:18:21.310 --> 00:18:25.030 align:middle line:84%
Time equals 5-- that's five
minutes-- at temperature of 850

00:18:25.030 --> 00:18:25.780 align:middle line:90%
in dry O2.

00:18:25.780 --> 00:18:29.620 align:middle line:84%
So it's going to grow five
minutes worth of oxide at 850

00:18:29.620 --> 00:18:31.090 align:middle line:90%
in dry O2.

00:18:31.090 --> 00:18:33.880 align:middle line:84%
And then we're going to plot
it using color number 2.

00:18:33.880 --> 00:18:35.950 align:middle line:84%
And then we're going to
do another five minutes

00:18:35.950 --> 00:18:37.280 align:middle line:90%
and plot it again.

00:18:37.280 --> 00:18:38.600 align:middle line:90%
So we can do sequential.

00:18:38.600 --> 00:18:40.960 align:middle line:84%
So that will be
after 10 minutes.

00:18:40.960 --> 00:18:42.340 align:middle line:84%
So you can look
at it and see how

00:18:42.340 --> 00:18:46.160 align:middle line:84%
the oxide grows and see what
happens to the boron profile

00:18:46.160 --> 00:18:47.840 align:middle line:90%
as the oxide grows.

00:18:47.840 --> 00:18:51.410 align:middle line:84%
So we're going to display
it at 5, 10, and 17 minutes.

00:18:51.410 --> 00:18:53.750 align:middle line:84%
We're going to display the
boron profile in the oxide.

00:18:53.750 --> 00:18:57.000 align:middle line:90%


00:18:57.000 --> 00:19:00.350 align:middle line:84%
So on slide number 9,
this is after five minutes

00:19:00.350 --> 00:19:02.840 align:middle line:90%
of now thermal oxidation.

00:19:02.840 --> 00:19:06.170 align:middle line:84%
We have an initial
oxide that's formed.

00:19:06.170 --> 00:19:10.760 align:middle line:84%
And this is what the
boron looks like.

00:19:10.760 --> 00:19:12.710 align:middle line:84%
And you notice the
boron near the surface

00:19:12.710 --> 00:19:15.740 align:middle line:84%
has been depleted, again,
because of that segregation.

00:19:15.740 --> 00:19:19.100 align:middle line:84%
And now you're oxidizing,
so you're consuming silicon.

00:19:19.100 --> 00:19:22.460 align:middle line:84%
So you're moving
into the silicon.

00:19:22.460 --> 00:19:24.800 align:middle line:84%
This interface is moving
towards the right.

00:19:24.800 --> 00:19:28.310 align:middle line:84%
And same segregation
as the previous case.

00:19:28.310 --> 00:19:30.770 align:middle line:84%
And now we have a
little bit of boron

00:19:30.770 --> 00:19:33.290 align:middle line:84%
that's been incorporated
in the silicon, not

00:19:33.290 --> 00:19:36.350 align:middle line:84%
so much by diffusion because,
again, but by consumption

00:19:36.350 --> 00:19:38.990 align:middle line:84%
because, remember, we initially
implant it with boron.

00:19:38.990 --> 00:19:40.970 align:middle line:90%
And then you start oxidizing.

00:19:40.970 --> 00:19:45.650 align:middle line:84%
If you go back to
the command file,

00:19:45.650 --> 00:19:48.540 align:middle line:84%
read in the
as-implanted structure.

00:19:48.540 --> 00:19:55.010 align:middle line:84%
So remember, we did a
save file of B1.imp.

00:19:55.010 --> 00:19:56.350 align:middle line:90%
How did I get that?

00:19:56.350 --> 00:20:00.180 align:middle line:84%
Well, that save file-- so this
is a way to just save time.

00:20:00.180 --> 00:20:04.860 align:middle line:84%
After we did the as-implanted,
we saved the file in something

00:20:04.860 --> 00:20:06.420 align:middle line:90%
called B1 dot inp.

00:20:06.420 --> 00:20:10.020 align:middle line:84%
And then we're going to call
it back later, that same file,

00:20:10.020 --> 00:20:13.680 align:middle line:90%
in a subsequent SUPREM run.

00:20:13.680 --> 00:20:17.063 align:middle line:84%
So here, I'm loading in
a file called B1.imp.

00:20:17.063 --> 00:20:18.480 align:middle line:84%
If you didn't want
to do that, you

00:20:18.480 --> 00:20:20.350 align:middle line:84%
could repeat the
simulation of the implant.

00:20:20.350 --> 00:20:22.058 align:middle line:84%
It's not going to take
very many minutes.

00:20:22.058 --> 00:20:24.390 align:middle line:84%
But if you have a complex
two-dimensional simulation,

00:20:24.390 --> 00:20:25.890 align:middle line:90%
you might as well save it.

00:20:25.890 --> 00:20:26.910 align:middle line:90%
It takes an hour to run.

00:20:26.910 --> 00:20:27.410 align:middle line:90%
Save it.

00:20:27.410 --> 00:20:29.280 align:middle line:84%
And you can always use
it again as the input

00:20:29.280 --> 00:20:32.640 align:middle line:84%
to another SUPREM simulation,
another diffusion or oxidation.

00:20:32.640 --> 00:20:35.450 align:middle line:90%


00:20:35.450 --> 00:20:41.840 align:middle line:84%
OK, so we are going to-- in this
here back on slide number 8,

00:20:41.840 --> 00:20:45.440 align:middle line:84%
we're going to load that
in, take whatever oxide

00:20:45.440 --> 00:20:47.540 align:middle line:84%
was on there off just to
make sure it's not there,

00:20:47.540 --> 00:20:50.960 align:middle line:84%
and diffuse it at 850 for
five minutes in dry O2.

00:20:50.960 --> 00:20:54.920 align:middle line:84%
We're going to grow a couple of
different thicknesses of oxide.

00:20:54.920 --> 00:20:57.687 align:middle line:84%
So I've consumed this, and
that's how a lot of the boron

00:20:57.687 --> 00:20:58.520 align:middle line:90%
has gotten in there.

00:20:58.520 --> 00:21:00.470 align:middle line:84%
And you see the segregation
from this point,

00:21:00.470 --> 00:21:03.600 align:middle line:84%
from here to here, that ratio
is about a factor of 10.

00:21:03.600 --> 00:21:06.470 align:middle line:84%
That's what we expect
because we said

00:21:06.470 --> 00:21:09.560 align:middle line:84%
k0 for segregation
of boron in SUPREM-IV

00:21:09.560 --> 00:21:12.700 align:middle line:90%
is about a factor of 10.

00:21:12.700 --> 00:21:14.830 align:middle line:84%
Go to the next slide,
slide number 10.

00:21:14.830 --> 00:21:16.750 align:middle line:84%
After another five
minutes, so I have a total

00:21:16.750 --> 00:21:18.820 align:middle line:90%
of 10 minutes of oxidation.

00:21:18.820 --> 00:21:22.150 align:middle line:84%
Again, you see, now you've
grown a little more oxide.

00:21:22.150 --> 00:21:23.320 align:middle line:90%
The yellow is thicker.

00:21:23.320 --> 00:21:25.420 align:middle line:84%
And you've consumed
more of the boron,

00:21:25.420 --> 00:21:27.800 align:middle line:84%
and the segregation is
causing this effect.

00:21:27.800 --> 00:21:30.370 align:middle line:84%
So this is not really diffusion
because the diffusion, look

00:21:30.370 --> 00:21:32.530 align:middle line:90%
how rapidly the boron drops.

00:21:32.530 --> 00:21:36.460 align:middle line:84%
If it were diffusing, this would
go straight through the oxide.

00:21:36.460 --> 00:21:38.830 align:middle line:84%
But it's not because
there is slow boron

00:21:38.830 --> 00:21:41.525 align:middle line:84%
diffusion in this
assumption in the oxide.

00:21:41.525 --> 00:21:43.150 align:middle line:84%
You see the boron
profile in the oxide.

00:21:43.150 --> 00:21:47.170 align:middle line:84%
And if we finally go to the
last, which is after the full 17

00:21:47.170 --> 00:21:53.170 align:middle line:84%
minutes, we have grown now
50 angstroms of gate oxide

00:21:53.170 --> 00:21:56.830 align:middle line:90%
at 850 in 17 minutes.

00:21:56.830 --> 00:22:00.280 align:middle line:84%
And the red is what it
looks like, the boron looks

00:22:00.280 --> 00:22:02.110 align:middle line:90%
like due to thermal oxidation.

00:22:02.110 --> 00:22:04.300 align:middle line:84%
You see a lot of the boron
has been incorporated

00:22:04.300 --> 00:22:06.040 align:middle line:84%
into the oxide
because of segregation

00:22:06.040 --> 00:22:09.970 align:middle line:90%
effects and consumption.

00:22:09.970 --> 00:22:12.410 align:middle line:84%
The black is
as-implanted, so that

00:22:12.410 --> 00:22:13.760 align:middle line:90%
was how it was as-implanted.

00:22:13.760 --> 00:22:16.530 align:middle line:84%
If I thermally oxidize
it, I get the red curve.

00:22:16.530 --> 00:22:18.770 align:middle line:84%
You can see it's
depleted at the surface,

00:22:18.770 --> 00:22:21.260 align:middle line:90%
and it's piled up in the oxide.

00:22:21.260 --> 00:22:23.300 align:middle line:84%
Instead of thermally
oxidizing, let's say

00:22:23.300 --> 00:22:26.240 align:middle line:84%
I didn't want to grow my gate
oxide, I just deposit it,

00:22:26.240 --> 00:22:28.070 align:middle line:90%
50 angstroms at 850.

00:22:28.070 --> 00:22:29.670 align:middle line:84%
The boron profile
is quite different.

00:22:29.670 --> 00:22:32.340 align:middle line:90%
It's the blue.

00:22:32.340 --> 00:22:33.450 align:middle line:90%
So why is that?

00:22:33.450 --> 00:22:35.040 align:middle line:84%
So there's two
different cases here.

00:22:35.040 --> 00:22:36.810 align:middle line:84%
In the case of if
I do an implant

00:22:36.810 --> 00:22:39.570 align:middle line:84%
and I thermally oxidize
it, I consume silicon.

00:22:39.570 --> 00:22:41.760 align:middle line:84%
And I suck some of that
boron into the oxide,

00:22:41.760 --> 00:22:44.010 align:middle line:84%
and then it segregates
by segregation.

00:22:44.010 --> 00:22:45.030 align:middle line:90%
So you see?

00:22:45.030 --> 00:22:48.310 align:middle line:84%
The boron concentration is
relatively low at the surface.

00:22:48.310 --> 00:22:50.130 align:middle line:84%
If instead of
thermally oxidizing

00:22:50.130 --> 00:22:53.130 align:middle line:84%
I just implant the
boron, place an oxide

00:22:53.130 --> 00:22:57.150 align:middle line:84%
down there by a chemical
vapor deposition process,

00:22:57.150 --> 00:23:00.220 align:middle line:84%
then I don't consume
any of the silicon.

00:23:00.220 --> 00:23:01.750 align:middle line:90%
So the boron stays a lot higher.

00:23:01.750 --> 00:23:05.170 align:middle line:84%
So I have about a factor of
two more boron at the surface.

00:23:05.170 --> 00:23:08.460 align:middle line:84%
So you can imagine you would get
different device characteristics

00:23:08.460 --> 00:23:11.940 align:middle line:84%
due to this slightly
different ways of forming

00:23:11.940 --> 00:23:16.080 align:middle line:84%
this oxide because it has an
impact on the boron profile

00:23:16.080 --> 00:23:17.738 align:middle line:90%
by different diffusion.

00:23:17.738 --> 00:23:19.530 align:middle line:84%
Well, the diffusion
coefficient's the same,

00:23:19.530 --> 00:23:21.810 align:middle line:84%
but it's really different
segregation and the fact

00:23:21.810 --> 00:23:23.730 align:middle line:84%
that in one case we're
consuming silicon.

00:23:23.730 --> 00:23:26.750 align:middle line:90%
In the other case, we're not.

00:23:26.750 --> 00:23:28.430 align:middle line:84%
OK, that's just
a simple example.

00:23:28.430 --> 00:23:30.400 align:middle line:84%
I had to use-- you
see all these points.

00:23:30.400 --> 00:23:32.400 align:middle line:84%
I had to use a really
fine grid in order for you

00:23:32.400 --> 00:23:35.840 align:middle line:90%
to see this effect.

00:23:35.840 --> 00:23:37.910 align:middle line:84%
So let me talk a little
bit about that grid dot

00:23:37.910 --> 00:23:41.330 align:middle line:90%
fac and the gridding.

00:23:41.330 --> 00:23:43.080 align:middle line:84%
When you have very
shallow profiles,

00:23:43.080 --> 00:23:46.430 align:middle line:84%
which is mostly what you're
doing these days for CMOS,

00:23:46.430 --> 00:23:48.170 align:middle line:90%
and thin oxides--

00:23:48.170 --> 00:23:49.430 align:middle line:90%
oh, OK, here we go.

00:23:49.430 --> 00:23:51.260 align:middle line:90%
This gives us the answer.

00:23:51.260 --> 00:23:56.720 align:middle line:84%
If you use the default
grid, then the grid spacing

00:23:56.720 --> 00:23:58.400 align:middle line:90%
is about 0.1 micron.

00:23:58.400 --> 00:24:00.350 align:middle line:90%
So there's about 0.1 micron.

00:24:00.350 --> 00:24:04.530 align:middle line:84%
That's actually bigger
than a lot of devices.

00:24:04.530 --> 00:24:07.190 align:middle line:90%
So it's much too crude.

00:24:07.190 --> 00:24:11.510 align:middle line:84%
So we can multiply
that by a small number,

00:24:11.510 --> 00:24:13.820 align:middle line:84%
like the grid dot fac
and make that grid

00:24:13.820 --> 00:24:15.360 align:middle line:90%
spacing much, much smaller.

00:24:15.360 --> 00:24:17.660 align:middle line:84%
So in this particular
example, I'm

00:24:17.660 --> 00:24:22.070 align:middle line:84%
showing you where we did
that same implant of boron

00:24:22.070 --> 00:24:25.175 align:middle line:84%
and then 850, 17-minute
oxidation, with a grid

00:24:25.175 --> 00:24:28.420 align:middle line:90%
dot fac of 0.4.

00:24:28.420 --> 00:24:29.510 align:middle line:90%
It's still very coarse.

00:24:29.510 --> 00:24:30.010 align:middle line:90%
You can see.

00:24:30.010 --> 00:24:32.420 align:middle line:84%
This doesn't really have
much of a shape to it.

00:24:32.420 --> 00:24:34.490 align:middle line:84%
There's a point here
where we've solved.

00:24:34.490 --> 00:24:35.510 align:middle line:90%
There's a point here.

00:24:35.510 --> 00:24:36.385 align:middle line:90%
There's a point here.

00:24:36.385 --> 00:24:38.650 align:middle line:84%
But it's just very
jagged looking

00:24:38.650 --> 00:24:40.330 align:middle line:90%
because the grid is too coarse.

00:24:40.330 --> 00:24:43.810 align:middle line:84%
And in fact, in the oxide
you're getting almost no detail

00:24:43.810 --> 00:24:45.593 align:middle line:84%
or information at all
because you really

00:24:45.593 --> 00:24:47.260 align:middle line:84%
don't have any grid
points in the oxide.

00:24:47.260 --> 00:24:50.360 align:middle line:84%
You've got one at the interface
and one at the surface.

00:24:50.360 --> 00:24:53.470 align:middle line:84%
So for this particular
example, a grid fac of 0.4

00:24:53.470 --> 00:24:54.280 align:middle line:90%
is way too crude.

00:24:54.280 --> 00:24:55.780 align:middle line:84%
So this is something
you always want

00:24:55.780 --> 00:24:57.820 align:middle line:90%
to check by doing a quick test.

00:24:57.820 --> 00:25:01.430 align:middle line:90%
What kind of a grid do I want?

00:25:01.430 --> 00:25:04.790 align:middle line:84%
If you go on to the next
slide, slide number 13, here's

00:25:04.790 --> 00:25:10.490 align:middle line:84%
a factor of 10, finer
grid, grid dot fac of 0.04.

00:25:10.490 --> 00:25:12.090 align:middle line:90%
Still, it looks pretty good.

00:25:12.090 --> 00:25:14.390 align:middle line:84%
Now, it's starting to
look like a smooth curve.

00:25:14.390 --> 00:25:15.685 align:middle line:90%
It's not all jagged looking.

00:25:15.685 --> 00:25:17.060 align:middle line:84%
And it has a shape
that you would

00:25:17.060 --> 00:25:20.930 align:middle line:84%
imagine could be associated
with diffusion and--

00:25:20.930 --> 00:25:22.790 align:middle line:90%
ion implantation and diffusion.

00:25:22.790 --> 00:25:24.890 align:middle line:84%
But the oxide
grid, in the oxide,

00:25:24.890 --> 00:25:27.770 align:middle line:84%
it's still too coarse
because the oxide is thin.

00:25:27.770 --> 00:25:30.320 align:middle line:84%
It's only on the order
of 10 to 50 angstroms

00:25:30.320 --> 00:25:31.640 align:middle line:90%
during this oxidation.

00:25:31.640 --> 00:25:33.620 align:middle line:90%
So I'm only getting what?

00:25:33.620 --> 00:25:34.880 align:middle line:90%
One point in the oxide.

00:25:34.880 --> 00:25:37.490 align:middle line:84%
I have one at the interface,
one in the oxide, and one here.

00:25:37.490 --> 00:25:40.720 align:middle line:90%
That's still not enough.

00:25:40.720 --> 00:25:45.130 align:middle line:84%
So if we go to the
next slide, slide

00:25:45.130 --> 00:25:48.500 align:middle line:84%
number 14, and as
I mentioned before,

00:25:48.500 --> 00:25:51.700 align:middle line:84%
we use this particular statement
to make a very fine grid,

00:25:51.700 --> 00:25:53.230 align:middle line:90%
and just inside the oxide.

00:25:53.230 --> 00:25:56.410 align:middle line:84%
We don't want to make
it that fine everywhere.

00:25:56.410 --> 00:26:01.300 align:middle line:84%
Then we use this--
you can insert

00:26:01.300 --> 00:26:05.680 align:middle line:84%
a statement called methoddy
dot oxide equals 0.0005.

00:26:05.680 --> 00:26:09.770 align:middle line:84%
That puts in a 5 angstrom
grid in the oxide,

00:26:09.770 --> 00:26:10.900 align:middle line:90%
which kind of makes sense.

00:26:10.900 --> 00:26:14.740 align:middle line:84%
You have a 50 angstrom
oxide you're growing.

00:26:14.740 --> 00:26:18.730 align:middle line:84%
You'd like to have something
like a 5 angstrom grid

00:26:18.730 --> 00:26:19.960 align:middle line:90%
in that oxide.

00:26:19.960 --> 00:26:23.810 align:middle line:84%
And now you can start to see
what it really looks like.

00:26:23.810 --> 00:26:25.510 align:middle line:84%
Remember, before I
had one point here,

00:26:25.510 --> 00:26:27.280 align:middle line:90%
one point here, and one here.

00:26:27.280 --> 00:26:29.775 align:middle line:84%
It's a solution looked
completely different.

00:26:29.775 --> 00:26:31.150 align:middle line:84%
This is what it
would have looked

00:26:31.150 --> 00:26:32.948 align:middle line:84%
like if you just
hadn't bothered to put

00:26:32.948 --> 00:26:34.240 align:middle line:90%
in a special grid in the oxide.

00:26:34.240 --> 00:26:36.370 align:middle line:84%
You'd think it was a
triangular sort of profile.

00:26:36.370 --> 00:26:37.600 align:middle line:90%
It's not triangular at all.

00:26:37.600 --> 00:26:40.520 align:middle line:84%
The boron actually looks sort
of flat topped in the oxide

00:26:40.520 --> 00:26:42.270 align:middle line:90%
and then goes down very rapidly.

00:26:42.270 --> 00:26:44.960 align:middle line:84%
So you really need to
keep an eye on your grid.

00:26:44.960 --> 00:26:49.490 align:middle line:84%
And you typically want to
run problems or solutions

00:26:49.490 --> 00:26:51.980 align:middle line:84%
for a number of
different grid spacings

00:26:51.980 --> 00:26:54.350 align:middle line:84%
to get a feel for what
grid is appropriate

00:26:54.350 --> 00:27:01.470 align:middle line:84%
and what grid gives you
physically realistic results.

00:27:01.470 --> 00:27:04.710 align:middle line:84%
OK, so that's a little bit of
a trivial example on oxidation,

00:27:04.710 --> 00:27:06.240 align:middle line:84%
but I just wanted
to make the point

00:27:06.240 --> 00:27:08.550 align:middle line:84%
of how important
knowing your grid

00:27:08.550 --> 00:27:10.360 align:middle line:84%
is because you can
get a solution.

00:27:10.360 --> 00:27:12.660 align:middle line:84%
You look at it, and you
think it shows you something.

00:27:12.660 --> 00:27:15.288 align:middle line:84%
And in fact, it could be
physically not meaningful if you

00:27:15.288 --> 00:27:16.455 align:middle line:90%
haven't used the right grid.

00:27:16.455 --> 00:27:19.570 align:middle line:90%


00:27:19.570 --> 00:27:22.860 align:middle line:84%
So let's go on to slide number
15 and example number two.

00:27:22.860 --> 00:27:24.918 align:middle line:84%
I want to talk about
ion implant modeling.

00:27:24.918 --> 00:27:27.210 align:middle line:84%
Remember, there's a number
of different analytic models

00:27:27.210 --> 00:27:29.500 align:middle line:90%
that we talked about.

00:27:29.500 --> 00:27:31.200 align:middle line:90%
We said, you can use a Gaussian.

00:27:31.200 --> 00:27:32.730 align:middle line:90%
You can use a Pearson-IV.

00:27:32.730 --> 00:27:35.370 align:middle line:90%
You can use dual Pearson.

00:27:35.370 --> 00:27:38.760 align:middle line:84%
And that there are tables
in the literature that

00:27:38.760 --> 00:27:42.510 align:middle line:84%
give the first three moments,
the RP, the delta RP,

00:27:42.510 --> 00:27:43.230 align:middle line:90%
and the skewness.

00:27:43.230 --> 00:27:47.580 align:middle line:84%
Those tables have been
tabulated since the 1970s or so.

00:27:47.580 --> 00:27:50.280 align:middle line:84%
And they've been
updated over time--

00:27:50.280 --> 00:27:51.780 align:middle line:90%
of the implant distributions.

00:27:51.780 --> 00:27:54.210 align:middle line:84%
And they've been produced
by theory and also

00:27:54.210 --> 00:27:56.450 align:middle line:90%
by fitting to experiment.

00:27:56.450 --> 00:27:58.750 align:middle line:84%
This is the most common
analytic formulation

00:27:58.750 --> 00:28:00.580 align:middle line:90%
that you will see in simulators.

00:28:00.580 --> 00:28:01.750 align:middle line:90%
It's called the Pearson-IV.

00:28:01.750 --> 00:28:04.330 align:middle line:84%
We talked about
that distribution.

00:28:04.330 --> 00:28:09.850 align:middle line:84%
And we said it does a pretty
good job of replicating profiles

00:28:09.850 --> 00:28:11.050 align:middle line:90%
into amorphous case.

00:28:11.050 --> 00:28:13.870 align:middle line:84%
It does not model
channeling all that well.

00:28:13.870 --> 00:28:16.660 align:middle line:84%
Channeling requires the
use of more parameters,

00:28:16.660 --> 00:28:19.490 align:middle line:90%
generally by curve fitting.

00:28:19.490 --> 00:28:22.960 align:middle line:84%
So a Pearson-IV is a single
Pearson distribution.

00:28:22.960 --> 00:28:24.460 align:middle line:84%
If you want to do
channeling, you'll

00:28:24.460 --> 00:28:27.190 align:middle line:84%
often see dual Pearson, meaning
two different Pearson-IV

00:28:27.190 --> 00:28:29.710 align:middle line:90%
profiles are added together.

00:28:29.710 --> 00:28:32.900 align:middle line:90%
And lookup tables are used.

00:28:32.900 --> 00:28:34.990 align:middle line:84%
One of the things you
need to be aware of

00:28:34.990 --> 00:28:37.750 align:middle line:84%
are inaccuracies in stopping
powers, particularly

00:28:37.750 --> 00:28:42.730 align:middle line:84%
the electronic stopping
at low energies and even

00:28:42.730 --> 00:28:44.050 align:middle line:90%
nuclear stopping powers.

00:28:44.050 --> 00:28:46.270 align:middle line:84%
At very low energies, a lot
of these stopping powers

00:28:46.270 --> 00:28:47.750 align:middle line:90%
are not known that well.

00:28:47.750 --> 00:28:51.550 align:middle line:84%
So if you're trying to simulate
energies below, say, 10 keV,

00:28:51.550 --> 00:28:55.120 align:middle line:84%
20 keV, depending
on the dopant, you

00:28:55.120 --> 00:28:57.800 align:middle line:90%
may not get very good results.

00:28:57.800 --> 00:29:00.800 align:middle line:84%
Dopants that are widely
used in Silicon technology,

00:29:00.800 --> 00:29:02.480 align:middle line:84%
they're constantly
updating these tables

00:29:02.480 --> 00:29:03.980 align:middle line:84%
to try to make them
a little better,

00:29:03.980 --> 00:29:06.540 align:middle line:84%
more accurately represent
reality in experiments.

00:29:06.540 --> 00:29:09.710 align:middle line:84%
But some dopants that are not
used that often at low energies,

00:29:09.710 --> 00:29:12.140 align:middle line:84%
you'll simulate, and you won't
get a very good simulation

00:29:12.140 --> 00:29:13.430 align:middle line:90%
compared to the actual data.

00:29:13.430 --> 00:29:16.140 align:middle line:90%


00:29:16.140 --> 00:29:18.140 align:middle line:84%
So let's go on to
slide number 16,

00:29:18.140 --> 00:29:21.470 align:middle line:84%
and this is an example
of a SUPREM input file

00:29:21.470 --> 00:29:23.180 align:middle line:84%
where we're using
tabulated moments.

00:29:23.180 --> 00:29:28.160 align:middle line:84%
So SUPREM has in its database
tables of all these moments.

00:29:28.160 --> 00:29:31.580 align:middle line:84%
And it's using tabulated moments
to evaluate and to plot for you

00:29:31.580 --> 00:29:33.150 align:middle line:90%
an implant distribution.

00:29:33.150 --> 00:29:36.980 align:middle line:84%
So here's an example of
ion-implanted phosphorus.

00:29:36.980 --> 00:29:38.630 align:middle line:90%
So we define our mesh.

00:29:38.630 --> 00:29:41.210 align:middle line:90%
Here's a grid fac equal 0.1.

00:29:41.210 --> 00:29:44.600 align:middle line:84%
So it's not all
that fine of a mesh.

00:29:44.600 --> 00:29:45.800 align:middle line:90%
The substrate is boron.

00:29:45.800 --> 00:29:47.330 align:middle line:84%
We're going to
implant phosphorus

00:29:47.330 --> 00:29:49.820 align:middle line:84%
at a particular
dose, [? 8014. ?]

00:29:49.820 --> 00:29:54.590 align:middle line:84%
Energy, not all that low,
about 30 keV, but somewhat low,

00:29:54.590 --> 00:29:57.590 align:middle line:84%
a 7-degree tilt. And we're
saying to use a Gaussian model,

00:29:57.590 --> 00:29:59.780 align:middle line:90%
very, very simple model.

00:29:59.780 --> 00:30:02.930 align:middle line:84%
Save it in a file
called Gaussian.saved,

00:30:02.930 --> 00:30:04.837 align:middle line:90%
and then plot it.

00:30:04.837 --> 00:30:06.170 align:middle line:90%
And then we're going to plot it.

00:30:06.170 --> 00:30:10.490 align:middle line:84%
In addition to plotting the
phosphorus that it calculated,

00:30:10.490 --> 00:30:13.810 align:middle line:90%
SUPREM has a nice way of--

00:30:13.810 --> 00:30:15.660 align:middle line:84%
using a command
called profile, you

00:30:15.660 --> 00:30:20.700 align:middle line:84%
can input into SUPREM xy data,
a matrix of concentration

00:30:20.700 --> 00:30:21.510 align:middle line:90%
versus depth.

00:30:21.510 --> 00:30:23.250 align:middle line:84%
And that's called the
profile statement.

00:30:23.250 --> 00:30:25.650 align:middle line:90%
It reads in phosphorus.

00:30:25.650 --> 00:30:26.943 align:middle line:90%
And the name of the file--

00:30:26.943 --> 00:30:28.110 align:middle line:90%
this is the particular name.

00:30:28.110 --> 00:30:31.260 align:middle line:84%
It's kind of ugly, but you can
call it whatever you want--

00:30:31.260 --> 00:30:36.600 align:middle line:84%
and use that to
plot the phosphorus.

00:30:36.600 --> 00:30:39.730 align:middle line:84%
So we can not only plot
the SUPREM simulation,

00:30:39.730 --> 00:30:42.250 align:middle line:84%
we can also plot the
actual SIMS data.

00:30:42.250 --> 00:30:45.570 align:middle line:84%
So this happens to be an implant
for which I have actual SIMS

00:30:45.570 --> 00:30:47.680 align:middle line:84%
data that I have
entered into this.

00:30:47.680 --> 00:30:52.960 align:middle line:84%
And we're going to compare that
data to the Gaussian solution.

00:30:52.960 --> 00:30:56.220 align:middle line:84%
So if you go on to slide
number 17, you'll see.

00:30:56.220 --> 00:31:00.900 align:middle line:84%
This is for that relatively
low-energy phosphorus implant.

00:31:00.900 --> 00:31:03.280 align:middle line:84%
The SIMS data here
is shown in red.

00:31:03.280 --> 00:31:05.730 align:middle line:84%
This is actual data obtained
from a company called

00:31:05.730 --> 00:31:06.390 align:middle line:90%
Charles Evans.

00:31:06.390 --> 00:31:10.080 align:middle line:84%
I think we've talked about
Evans Associates in this class.

00:31:10.080 --> 00:31:14.670 align:middle line:84%
They used a cesium beam with
a primary beam energy of 2 keV

00:31:14.670 --> 00:31:15.730 align:middle line:90%
to profile.

00:31:15.730 --> 00:31:17.920 align:middle line:90%
And this is what they got.

00:31:17.920 --> 00:31:20.530 align:middle line:84%
And the black line
is what SUPREM

00:31:20.530 --> 00:31:24.970 align:middle line:84%
says it should look like
using a Gaussian simulation.

00:31:24.970 --> 00:31:27.460 align:middle line:84%
And these are
default values that

00:31:27.460 --> 00:31:30.820 align:middle line:84%
are tabulated inside the
SUPREM-IV simulator using

00:31:30.820 --> 00:31:33.690 align:middle line:84%
the standard LSS range
parameters, RP and delta RP.

00:31:33.690 --> 00:31:35.440 align:middle line:84%
Remember, you only get
two for a Gaussian.

00:31:35.440 --> 00:31:39.410 align:middle line:84%
So compared to the SIMS,
it's not all that great.

00:31:39.410 --> 00:31:42.170 align:middle line:84%
The simulation does
not do a very good job.

00:31:42.170 --> 00:31:45.770 align:middle line:90%
It's too simplified of a model.

00:31:45.770 --> 00:31:49.390 align:middle line:84%
The stopping power is
apparently too small,

00:31:49.390 --> 00:31:53.590 align:middle line:84%
and the range is overestimated
by the theoretical calculation

00:31:53.590 --> 00:31:57.780 align:middle line:84%
compared to what was
experimentally observed.

00:31:57.780 --> 00:32:00.390 align:middle line:90%
Well, we can try another model.

00:32:00.390 --> 00:32:01.560 align:middle line:90%
Same SIMS data.

00:32:01.560 --> 00:32:03.520 align:middle line:84%
This time, we try
the black model,

00:32:03.520 --> 00:32:06.630 align:middle line:90%
which is the dual Pearson, OK?

00:32:06.630 --> 00:32:09.750 align:middle line:84%
Dual Pearson uses
more parameters.

00:32:09.750 --> 00:32:12.107 align:middle line:84%
It simulates this
sort of channel tail

00:32:12.107 --> 00:32:12.940 align:middle line:90%
a little bit better.

00:32:12.940 --> 00:32:14.610 align:middle line:84%
But again, the range
and the skewness

00:32:14.610 --> 00:32:18.210 align:middle line:84%
are both overestimated,
way too much skewness.

00:32:18.210 --> 00:32:19.410 align:middle line:90%
So what does this tell us?

00:32:19.410 --> 00:32:23.970 align:middle line:84%
Well, this basically tells us
that these tabulated moments are

00:32:23.970 --> 00:32:25.830 align:middle line:90%
not perfect for all dopants.

00:32:25.830 --> 00:32:28.920 align:middle line:84%
So take them with a grain of
salt, especially phosphorus.

00:32:28.920 --> 00:32:31.620 align:middle line:84%
Phosphorus [INAUDIBLE] used that
much in CMOS technology, right?

00:32:31.620 --> 00:32:33.720 align:middle line:84%
Shallow junctions for
n-type are typically

00:32:33.720 --> 00:32:37.380 align:middle line:84%
made by arsenic because
phosphorus diffuses too fast.

00:32:37.380 --> 00:32:40.620 align:middle line:84%
So not a whole lot of
energy and manpower

00:32:40.620 --> 00:32:43.710 align:middle line:84%
has gone into
improving the moment

00:32:43.710 --> 00:32:45.870 align:middle line:90%
tables for shallow phosphorus.

00:32:45.870 --> 00:32:49.470 align:middle line:84%
So if you happen to be using
phosphorus in your experiments,

00:32:49.470 --> 00:32:51.270 align:middle line:84%
take it with a grain
of salt if you're

00:32:51.270 --> 00:32:53.770 align:middle line:90%
using these tabulated values.

00:32:53.770 --> 00:32:55.898 align:middle line:84%
According to my data, it
doesn't fit that well.

00:32:55.898 --> 00:32:58.190 align:middle line:84%
Of course, there might be
something wrong with my data.

00:32:58.190 --> 00:32:59.330 align:middle line:90%
That's another possibility.

00:32:59.330 --> 00:33:03.250 align:middle line:84%
So exactly what's reality,
it's not always clear.

00:33:03.250 --> 00:33:05.620 align:middle line:84%
But interestingly,
on the next slide,

00:33:05.620 --> 00:33:08.350 align:middle line:84%
exact same data
this time compared

00:33:08.350 --> 00:33:10.150 align:middle line:90%
to Monte Carlo simulation.

00:33:10.150 --> 00:33:12.910 align:middle line:84%
Now, these Monte Carlo
simulations take a lot longer.

00:33:12.910 --> 00:33:14.230 align:middle line:90%
It's not an analytic.

00:33:14.230 --> 00:33:15.370 align:middle line:90%
It's a numerical solution.

00:33:15.370 --> 00:33:17.830 align:middle line:84%
You have to follow each
ion into the silicon

00:33:17.830 --> 00:33:20.380 align:middle line:84%
and see where it lands
up and then statistically

00:33:20.380 --> 00:33:21.590 align:middle line:90%
create a profile.

00:33:21.590 --> 00:33:24.920 align:middle line:84%
And that's what
the black is, OK?

00:33:24.920 --> 00:33:27.110 align:middle line:84%
And you can see the
black looks kind of jaggy

00:33:27.110 --> 00:33:29.270 align:middle line:84%
because, again,
you're statistically

00:33:29.270 --> 00:33:30.800 align:middle line:90%
creating this profile.

00:33:30.800 --> 00:33:36.350 align:middle line:84%
But interestingly, the black
does a reasonably good job

00:33:36.350 --> 00:33:38.020 align:middle line:90%
of agreeing with the SIMS.

00:33:38.020 --> 00:33:39.770 align:middle line:84%
Doesn't mean they're
right, but it kind of

00:33:39.770 --> 00:33:41.690 align:middle line:84%
gives me some
confidence that, when

00:33:41.690 --> 00:33:44.880 align:middle line:84%
I see a simulation agrees
pretty well with the SIMS data,

00:33:44.880 --> 00:33:49.160 align:middle line:84%
at least in terms of its range
and its delta RP, its width

00:33:49.160 --> 00:33:52.230 align:middle line:84%
here, that's probably
a pretty good sign.

00:33:52.230 --> 00:33:55.640 align:middle line:84%
So there's enough physics in
this Monte Carlo simulation

00:33:55.640 --> 00:33:58.290 align:middle line:84%
to reproduce the
data pretty well.

00:33:58.290 --> 00:34:02.360 align:middle line:84%
But notice, this is
how you tell SUPREM

00:34:02.360 --> 00:34:03.530 align:middle line:90%
to do a Monte Carlo implant.

00:34:03.530 --> 00:34:05.340 align:middle line:84%
You give it the
implant statement.

00:34:05.340 --> 00:34:07.580 align:middle line:84%
You tell it the species,
the dose, the energy.

00:34:07.580 --> 00:34:09.570 align:middle line:84%
Now, here you tell it
how you want to do it.

00:34:09.570 --> 00:34:10.070 align:middle line:90%
You see?

00:34:10.070 --> 00:34:13.310 align:middle line:84%
In prior, I had said
Gaussian or dual Pearson,

00:34:13.310 --> 00:34:17.570 align:middle line:84%
or if you say nothing, it
defaults probably to Pearson-IV.

00:34:17.570 --> 00:34:19.250 align:middle line:90%
Here, you said Monte Carlo.

00:34:19.250 --> 00:34:20.900 align:middle line:84%
Now, an important
thing when you do

00:34:20.900 --> 00:34:23.250 align:middle line:84%
Monte Carlo is to specify
the number of ions you

00:34:23.250 --> 00:34:25.810 align:middle line:84%
want it to shoot into
the sample and to follow.

00:34:25.810 --> 00:34:31.270 align:middle line:84%
So this is 25,000 ions, not very
many, and tilt and rotation.

00:34:31.270 --> 00:34:35.280 align:middle line:84%
You need at least 10,000
to get good accuracy.

00:34:35.280 --> 00:34:38.850 align:middle line:84%
Probably, 100,000 is better
because you can see here,

00:34:38.850 --> 00:34:41.580 align:middle line:84%
after I'm two decades
beyond the peak,

00:34:41.580 --> 00:34:43.230 align:middle line:90%
I start to get a lot of noise.

00:34:43.230 --> 00:34:45.429 align:middle line:90%
So the noise comes in.

00:34:45.429 --> 00:34:48.270 align:middle line:84%
So I'm really only getting
two decades of smooth data.

00:34:48.270 --> 00:34:50.639 align:middle line:90%
That's with 25,000 ions.

00:34:50.639 --> 00:34:52.920 align:middle line:84%
In a one-dimensional
simulation, this isn't too bad.

00:34:52.920 --> 00:34:54.510 align:middle line:84%
It might only take
5, 10 minutes.

00:34:54.510 --> 00:34:55.270 align:middle line:90%
No big deal.

00:34:55.270 --> 00:34:56.699 align:middle line:90%
But now this is just 1D.

00:34:56.699 --> 00:35:01.300 align:middle line:84%
If I'm doing this in 2D across
the channel of a MOSFET, that 5,

00:35:01.300 --> 00:35:04.540 align:middle line:84%
10 minutes goes to be three
or four hours or more.

00:35:04.540 --> 00:35:09.130 align:middle line:84%
So you have to really
compromise to a certain extent.

00:35:09.130 --> 00:35:11.160 align:middle line:84%
So what people will
do sometimes is

00:35:11.160 --> 00:35:15.030 align:middle line:84%
fit the 1D profile using
Monte Carlo and then fit to it

00:35:15.030 --> 00:35:19.680 align:middle line:84%
an analytic solution by changing
some of the default parameters.

00:35:19.680 --> 00:35:22.890 align:middle line:84%
And then use that analytic in
the two-dimensional simulation

00:35:22.890 --> 00:35:26.640 align:middle line:84%
as a way of getting around
spending so much time.

00:35:26.640 --> 00:35:32.210 align:middle line:84%
So that's just an example of how
actual SUPREM outputs compare

00:35:32.210 --> 00:35:36.640 align:middle line:90%
to real data.

00:35:36.640 --> 00:35:37.640 align:middle line:90%
Let's take another case.

00:35:37.640 --> 00:35:38.598 align:middle line:90%
So that was phosphorus.

00:35:38.598 --> 00:35:41.700 align:middle line:84%
As I said, phosphorus is
not all that widely used.

00:35:41.700 --> 00:35:43.910 align:middle line:84%
Here's the case for 30
kilovolts, same energy,

00:35:43.910 --> 00:35:48.380 align:middle line:84%
but this time arsenic, using
the dual Pearson analytic.

00:35:48.380 --> 00:35:52.880 align:middle line:84%
Again, the SIMS data
is the red line.

00:35:52.880 --> 00:35:54.950 align:middle line:90%
And the calculated is the black.

00:35:54.950 --> 00:35:56.570 align:middle line:84%
And this time, with
the dual Pearson,

00:35:56.570 --> 00:35:57.740 align:middle line:90%
it does a pretty good job.

00:35:57.740 --> 00:36:01.460 align:middle line:84%
You got the range almost just
right and even the broadening,

00:36:01.460 --> 00:36:03.080 align:middle line:90%
not quite, but pretty close.

00:36:03.080 --> 00:36:06.020 align:middle line:84%
The shape are much more
accurate than for phosphorus.

00:36:06.020 --> 00:36:08.300 align:middle line:84%
I don't know why,
but I'm guessing

00:36:08.300 --> 00:36:11.150 align:middle line:84%
it's because shallow arsenic
junctions are the way people

00:36:11.150 --> 00:36:12.270 align:middle line:90%
make junctions these days.

00:36:12.270 --> 00:36:15.140 align:middle line:84%
And so people have
updated in SUPREM

00:36:15.140 --> 00:36:17.930 align:middle line:84%
these tables, these
tables of moments

00:36:17.930 --> 00:36:22.310 align:middle line:84%
to fit better the
experimental data.

00:36:22.310 --> 00:36:25.680 align:middle line:84%
Arsenic is also heavier,
dominated by nuclear stopping,

00:36:25.680 --> 00:36:27.290 align:middle line:84%
which is a little
better understood

00:36:27.290 --> 00:36:29.390 align:middle line:90%
than electronic stopping.

00:36:29.390 --> 00:36:31.520 align:middle line:84%
Remember, we said electronic
stopping powers always

00:36:31.520 --> 00:36:33.740 align:middle line:84%
have a little bit of
fuzziness about them.

00:36:33.740 --> 00:36:35.210 align:middle line:84%
Phosphorus is going
to be lighter.

00:36:35.210 --> 00:36:36.570 align:middle line:90%
It has more electronic stopping.

00:36:36.570 --> 00:36:37.530 align:middle line:90%
Maybe that's why.

00:36:37.530 --> 00:36:40.230 align:middle line:84%
But again, take the profiles
you get with a grain of salt

00:36:40.230 --> 00:36:42.180 align:middle line:84%
unless you've checked
them out experimentally.

00:36:42.180 --> 00:36:45.040 align:middle line:90%


00:36:45.040 --> 00:36:48.910 align:middle line:84%
Slide 21, that same data,
this time with Monte Carlo.

00:36:48.910 --> 00:36:50.292 align:middle line:90%
Excellent job.

00:36:50.292 --> 00:36:51.250 align:middle line:90%
This looks even better.

00:36:51.250 --> 00:36:54.530 align:middle line:84%
It's got the broadening
a little better.

00:36:54.530 --> 00:36:58.360 align:middle line:84%
So it looks quite good
using Monte Carlo.

00:36:58.360 --> 00:37:01.150 align:middle line:84%
Of course, Monte Carlo
took longer to generate,

00:37:01.150 --> 00:37:03.850 align:middle line:90%
longer to simulate.

00:37:03.850 --> 00:37:05.380 align:middle line:84%
Another advantage
of the Monte Carlo

00:37:05.380 --> 00:37:07.588 align:middle line:84%
besides the fact that it
seems to be pretty accurate,

00:37:07.588 --> 00:37:09.760 align:middle line:84%
it has pretty good
comparison to data,

00:37:09.760 --> 00:37:11.740 align:middle line:84%
you can generate
profiles of [INAUDIBLE]

00:37:11.740 --> 00:37:13.270 align:middle line:90%
interstitials and vacancies.

00:37:13.270 --> 00:37:14.890 align:middle line:90%
And we need those profiles.

00:37:14.890 --> 00:37:16.960 align:middle line:84%
If you want to use
those profiles,

00:37:16.960 --> 00:37:21.700 align:middle line:84%
you can use them in subsequent
diffusion simulations in order

00:37:21.700 --> 00:37:23.740 align:middle line:90%
to simulate TED.

00:37:23.740 --> 00:37:27.190 align:middle line:84%
If you do an implant and
you don't tell the simulator

00:37:27.190 --> 00:37:30.280 align:middle line:84%
to use a damage model, it's not
going to be able to simulate TED

00:37:30.280 --> 00:37:32.600 align:middle line:84%
because it needs to
have some damage model.

00:37:32.600 --> 00:37:36.040 align:middle line:84%
So Monte Carlo is also very
useful for that purpose.

00:37:36.040 --> 00:37:38.760 align:middle line:90%


00:37:38.760 --> 00:37:40.550 align:middle line:90%
OK, so let's go on to slide 22.

00:37:40.550 --> 00:37:44.360 align:middle line:84%
So those were a couple of
examples of simple oxidation,

00:37:44.360 --> 00:37:45.890 align:middle line:90%
simple ion implantation.

00:37:45.890 --> 00:37:49.670 align:middle line:90%
Now we get to the more--

00:37:49.670 --> 00:37:52.560 align:middle line:84%
a little more exciting models,
a little more complicated.

00:37:52.560 --> 00:37:56.650 align:middle line:84%
There are three major
diffusion models in SUPREM-IV.

00:37:56.650 --> 00:37:58.270 align:middle line:84%
And these are what
they're called.

00:37:58.270 --> 00:38:00.430 align:middle line:84%
The way you invoke a
different model in SUPREM-IV

00:38:00.430 --> 00:38:02.320 align:middle line:90%
is you use the method statement.

00:38:02.320 --> 00:38:05.890 align:middle line:84%
And there are three methods
for solving the differential

00:38:05.890 --> 00:38:08.680 align:middle line:84%
equations associated with
diffusion in SUPREM-IV.

00:38:08.680 --> 00:38:09.550 align:middle line:90%
There's PD.

00:38:09.550 --> 00:38:11.230 align:middle line:84%
That's Partial
Differential equation.

00:38:11.230 --> 00:38:15.617 align:middle line:84%
PD dot Fermi is a method that
takes into account the impact

00:38:15.617 --> 00:38:17.200 align:middle line:84%
of the Fermi level,
just like the name

00:38:17.200 --> 00:38:20.560 align:middle line:84%
would suggest on the dopant
diffusion coefficient.

00:38:20.560 --> 00:38:23.290 align:middle line:84%
For example, this is
an equation that SUPREM

00:38:23.290 --> 00:38:25.178 align:middle line:90%
uses for n-type dopants.

00:38:25.178 --> 00:38:26.470 align:middle line:90%
You're very familiar with this.

00:38:26.470 --> 00:38:28.270 align:middle line:84%
It has an n over
ni, and it may be

00:38:28.270 --> 00:38:31.120 align:middle line:84%
an n over ni squared
depending on the dopant.

00:38:31.120 --> 00:38:34.000 align:middle line:84%
And it has stored in
it values for D0, D

00:38:34.000 --> 00:38:37.330 align:middle line:84%
minus, D double minus
for all the dopants.

00:38:37.330 --> 00:38:38.980 align:middle line:84%
It models
concentration-dependent

00:38:38.980 --> 00:38:42.190 align:middle line:84%
diffusion, but it does
not model TED or OED.

00:38:42.190 --> 00:38:44.120 align:middle line:90%
So it's quite simple.

00:38:44.120 --> 00:38:45.430 align:middle line:90%
It's very fast.

00:38:45.430 --> 00:38:48.400 align:middle line:84%
And the nice thing is there's
relatively few parameters,

00:38:48.400 --> 00:38:50.970 align:middle line:90%
just a few D parameters.

00:38:50.970 --> 00:38:52.910 align:middle line:90%
And you can get your answer.

00:38:52.910 --> 00:38:55.640 align:middle line:84%
So that's the nice
thing about it.

00:38:55.640 --> 00:38:57.450 align:middle line:84%
And it does model
concentration-dependent.

00:38:57.450 --> 00:38:59.117 align:middle line:84%
So this is the first
thing you would use

00:38:59.117 --> 00:39:00.940 align:middle line:90%
because it's relatively fast.

00:39:00.940 --> 00:39:05.860 align:middle line:84%
The next method, the next level
of complication is PD.trans.

00:39:05.860 --> 00:39:09.320 align:middle line:84%
And it takes into
account the Fermi level.

00:39:09.320 --> 00:39:12.280 align:middle line:84%
So it already has this model
built in, the Fermi model,

00:39:12.280 --> 00:39:18.070 align:middle line:84%
as well as the impact of
nonequilibrium interstitial

00:39:18.070 --> 00:39:22.630 align:middle line:84%
and vacancy profiles on the
diffusion, but not the other way

00:39:22.630 --> 00:39:23.890 align:middle line:90%
around.

00:39:23.890 --> 00:39:28.180 align:middle line:84%
It will not show you the
impact of dopant diffusion

00:39:28.180 --> 00:39:32.660 align:middle line:84%
on the motion of
interstitials and vacancies.

00:39:32.660 --> 00:39:34.810 align:middle line:84%
So it's not fully
coupled, but it

00:39:34.810 --> 00:39:38.800 align:middle line:84%
does take into account
the impact of the ions

00:39:38.800 --> 00:39:41.170 align:middle line:90%
on the dopant diffusion.

00:39:41.170 --> 00:39:44.170 align:middle line:90%
It's very useful for OED.

00:39:44.170 --> 00:39:47.230 align:middle line:84%
So people tend to use it for
oxidation-enhanced diffusion.

00:39:47.230 --> 00:39:50.770 align:middle line:84%
Or you can use it for
transient-enhanced diffusion

00:39:50.770 --> 00:39:54.950 align:middle line:84%
with relatively low
doping concentrations.

00:39:54.950 --> 00:39:57.520 align:middle line:84%
If you have higher doping
concentrations, then

00:39:57.520 --> 00:40:02.410 align:middle line:84%
the coupled diffusion of
the pair, of the dopant plus

00:40:02.410 --> 00:40:04.510 align:middle line:84%
the point defect actually
affects the point defect

00:40:04.510 --> 00:40:05.300 align:middle line:90%
profile.

00:40:05.300 --> 00:40:07.990 align:middle line:84%
And so you need something more
sophisticated than PD.trans.

00:40:07.990 --> 00:40:11.783 align:middle line:84%
And this is the model it uses,
the basic concept that you

00:40:11.783 --> 00:40:14.200 align:middle line:84%
should be familiar with now,
if you've done your homework,

00:40:14.200 --> 00:40:19.630 align:middle line:84%
is that the diffusivity is the
unperturbed diffusivity times

00:40:19.630 --> 00:40:24.560 align:middle line:84%
something in parentheses,
where it depends on F sub i.

00:40:24.560 --> 00:40:29.330 align:middle line:84%
So it takes into account the
enhancement in CI over CI star

00:40:29.330 --> 00:40:33.350 align:middle line:84%
that can happen when you do an
oxidation or the enhancement

00:40:33.350 --> 00:40:36.830 align:middle line:84%
in CV or CV star if
you do a nitridation

00:40:36.830 --> 00:40:38.130 align:middle line:90%
or if you do an implant.

00:40:38.130 --> 00:40:40.380 align:middle line:84%
And these things get
enlarged or suppressed.

00:40:40.380 --> 00:40:43.750 align:middle line:90%
So it'll take that into account.

00:40:43.750 --> 00:40:47.130 align:middle line:84%
The last method you can use
takes the longest in terms of it

00:40:47.130 --> 00:40:51.000 align:middle line:84%
can be very long
simulation times, PD.full.

00:40:51.000 --> 00:40:52.620 align:middle line:84%
The name comes from
the fact that it

00:40:52.620 --> 00:40:54.150 align:middle line:90%
is fully-coupled diffusion.

00:40:54.150 --> 00:40:55.480 align:middle line:90%
And what does that mean?

00:40:55.480 --> 00:41:00.330 align:middle line:84%
It means that the interstitials
and vacancies impact the flux

00:41:00.330 --> 00:41:02.610 align:middle line:90%
of the dopants, and vice versa.

00:41:02.610 --> 00:41:05.490 align:middle line:84%
The flux of the dopants
impact the interstitials

00:41:05.490 --> 00:41:08.130 align:middle line:90%
and vacancy diffusion.

00:41:08.130 --> 00:41:10.320 align:middle line:84%
This should be used
most of the time

00:41:10.320 --> 00:41:14.730 align:middle line:84%
if you are interested in
transient-enhanced diffusion.

00:41:14.730 --> 00:41:17.385 align:middle line:84%
And in high
concentrations, in general,

00:41:17.385 --> 00:41:19.620 align:middle line:84%
for instance, the
emitter push effect,

00:41:19.620 --> 00:41:24.330 align:middle line:84%
we talked about how phosphorus
can pair with interstitials

00:41:24.330 --> 00:41:26.580 align:middle line:84%
and, by diffusion,
drag the interstitials

00:41:26.580 --> 00:41:27.720 align:middle line:90%
into the substrate.

00:41:27.720 --> 00:41:30.420 align:middle line:84%
When it goes substitutional, it
releases those interstitials.

00:41:30.420 --> 00:41:34.110 align:middle line:84%
Those interstitials then cause
the boron base to broaden.

00:41:34.110 --> 00:41:35.490 align:middle line:84%
That was the
emitter push effect.

00:41:35.490 --> 00:41:37.920 align:middle line:84%
You'll never be able to get
that out of the Fermi model.

00:41:37.920 --> 00:41:38.760 align:middle line:90%
There's no way.

00:41:38.760 --> 00:41:41.290 align:middle line:84%
And even the trans
model won't have that.

00:41:41.290 --> 00:41:44.230 align:middle line:84%
So to simulate the
things like emitter push

00:41:44.230 --> 00:41:47.080 align:middle line:84%
effect, those types of
fully coupled cases,

00:41:47.080 --> 00:41:50.313 align:middle line:90%
you need this PD.full.

00:41:50.313 --> 00:41:51.980 align:middle line:84%
So those are three
different statements,

00:41:51.980 --> 00:41:57.020 align:middle line:84%
and you can compare the results
from all three statements

00:41:57.020 --> 00:41:58.520 align:middle line:90%
for a given situation.

00:41:58.520 --> 00:41:59.780 align:middle line:90%
Now, one thing I should say.

00:41:59.780 --> 00:42:02.450 align:middle line:84%
As you go from here
to here to here,

00:42:02.450 --> 00:42:06.200 align:middle line:84%
you're invoking more physics,
more chemistry, and also

00:42:06.200 --> 00:42:07.910 align:middle line:90%
more parameters.

00:42:07.910 --> 00:42:09.260 align:middle line:90%
That's one problem with this.

00:42:09.260 --> 00:42:13.230 align:middle line:84%
Sure, you can model the
emitter push effect.

00:42:13.230 --> 00:42:15.440 align:middle line:84%
But there's a lot of
parameters you need to know,

00:42:15.440 --> 00:42:19.040 align:middle line:84%
the diffusion rates of the
vacancies and the interstitials,

00:42:19.040 --> 00:42:20.630 align:middle line:84%
their recombination
of interfaces.

00:42:20.630 --> 00:42:22.820 align:middle line:84%
If those parameters
are in SUPREM,

00:42:22.820 --> 00:42:24.320 align:middle line:84%
they always have
default parameters.

00:42:24.320 --> 00:42:25.980 align:middle line:90%
But they may not be accurate.

00:42:25.980 --> 00:42:28.953 align:middle line:84%
So again, take everything you
simulate with a grain of salt.

00:42:28.953 --> 00:42:30.620 align:middle line:84%
If somebody has input
something in there

00:42:30.620 --> 00:42:32.120 align:middle line:84%
to the best of their
knowledge, that

00:42:32.120 --> 00:42:34.910 align:middle line:84%
might be the interstitial
diffusion diffusivity.

00:42:34.910 --> 00:42:36.800 align:middle line:84%
But maybe it wasn't
well characterized

00:42:36.800 --> 00:42:39.390 align:middle line:84%
at the temperature under the
conditions that you're using.

00:42:39.390 --> 00:42:41.750 align:middle line:84%
So you can get lots
of different profiles,

00:42:41.750 --> 00:42:43.460 align:middle line:84%
but how accurate
are they represent

00:42:43.460 --> 00:42:48.635 align:middle line:84%
experiment is something that you
need to determine for yourself.

00:42:48.635 --> 00:42:51.340 align:middle line:90%


00:42:51.340 --> 00:42:52.255 align:middle line:90%
So here's an example.

00:42:52.255 --> 00:42:54.630 align:middle line:84%
Let's look at a couple of
examples of different diffusion

00:42:54.630 --> 00:42:56.670 align:middle line:90%
profiles.

00:42:56.670 --> 00:43:00.780 align:middle line:84%
On page 23, this is a
simple 1D arsenic implant,

00:43:00.780 --> 00:43:03.160 align:middle line:84%
and then we're going to
do a long-time diffusion.

00:43:03.160 --> 00:43:04.140 align:middle line:90%
So the simplest thing--

00:43:04.140 --> 00:43:07.380 align:middle line:84%
is an implant arsenic at
30 keV, the certain dose,

00:43:07.380 --> 00:43:12.210 align:middle line:84%
intermediate dose, 2.6e14, and
diffuse it in a furnace at 1,000

00:43:12.210 --> 00:43:14.250 align:middle line:90%
degrees for 30 minutes.

00:43:14.250 --> 00:43:17.010 align:middle line:84%
Before we did the diffusion,
we put down an oxide cap,

00:43:17.010 --> 00:43:19.140 align:middle line:84%
not by oxidation,
but by deposition.

00:43:19.140 --> 00:43:21.870 align:middle line:84%
And so that oxide cap
helps prevent the arsenic

00:43:21.870 --> 00:43:25.620 align:middle line:84%
from evaporating
out of the wafer.

00:43:25.620 --> 00:43:30.140 align:middle line:84%
So this is the
actual command that

00:43:30.140 --> 00:43:35.020 align:middle line:84%
was used that specifies the
point defect model, methodpd dot

00:43:35.020 --> 00:43:35.520 align:middle line:90%
Fermi.

00:43:35.520 --> 00:43:37.280 align:middle line:84%
So we're using the
Fermi diffusion model.

00:43:37.280 --> 00:43:39.650 align:middle line:84%
And this is the diffusion
statement, 1,000 degrees

00:43:39.650 --> 00:43:41.540 align:middle line:90%
for 30 minutes inert.

00:43:41.540 --> 00:43:44.480 align:middle line:84%
I have some SIMS data here,
which is shown in the red.

00:43:44.480 --> 00:43:47.420 align:middle line:84%
And then the black dots
or the black circles

00:43:47.420 --> 00:43:50.190 align:middle line:84%
are the simulation
using a Gaussian model.

00:43:50.190 --> 00:43:52.670 align:middle line:90%
Here's a Gaussian and a Fermi.

00:43:52.670 --> 00:43:54.380 align:middle line:84%
And you can see it
actually reproduces

00:43:54.380 --> 00:43:56.030 align:middle line:90%
the data amazingly well.

00:43:56.030 --> 00:43:58.010 align:middle line:84%
It means that
somebody calibrated

00:43:58.010 --> 00:44:01.800 align:middle line:84%
SUPREM pretty accurately
to this particular furnace.

00:44:01.800 --> 00:44:03.920 align:middle line:90%
The Fermi models good enough.

00:44:03.920 --> 00:44:06.200 align:middle line:84%
And you say, well, how about
all that-- why didn't you

00:44:06.200 --> 00:44:08.510 align:middle line:90%
use PD.trans or fully coupled?

00:44:08.510 --> 00:44:11.480 align:middle line:84%
How did you get away with such
a simple 30-second simulation?

00:44:11.480 --> 00:44:13.310 align:middle line:90%
Well, the anneal is long.

00:44:13.310 --> 00:44:16.430 align:middle line:84%
So there's not going to
be any big damage or TED

00:44:16.430 --> 00:44:17.930 align:middle line:90%
effects after--

00:44:17.930 --> 00:44:19.970 align:middle line:84%
normal diffusion is
going to dominate this.

00:44:19.970 --> 00:44:22.710 align:middle line:84%
You need concentration
dependency how box-like it is.

00:44:22.710 --> 00:44:25.920 align:middle line:84%
So you need to use the Fermi
model for Fermi-level effects.

00:44:25.920 --> 00:44:28.830 align:middle line:84%
But you don't need to go
and invoking necessarily

00:44:28.830 --> 00:44:30.040 align:middle line:90%
TED or anything.

00:44:30.040 --> 00:44:33.420 align:middle line:84%
So if you know you have a
case where TED effects are not

00:44:33.420 --> 00:44:35.670 align:middle line:84%
that prevalent, you might
as well use the Fermi model.

00:44:35.670 --> 00:44:39.300 align:middle line:84%
It'll go a lot faster, and in
a two-dimensional simulation,

00:44:39.300 --> 00:44:43.210 align:middle line:84%
that could save
you a lot of time.

00:44:43.210 --> 00:44:47.250 align:middle line:84%
Here's that same simulation
here on slide 24.

00:44:47.250 --> 00:44:51.970 align:middle line:84%
But this time, we used
the fully coupled model.

00:44:51.970 --> 00:44:55.770 align:middle line:84%
So when we did the simulation,
instead of methodpd dot Fermi,

00:44:55.770 --> 00:44:58.470 align:middle line:90%
we said methodpd dot full.

00:44:58.470 --> 00:45:01.050 align:middle line:84%
And the simulation
is the black line.

00:45:01.050 --> 00:45:02.760 align:middle line:84%
It agrees still very
well with the data,

00:45:02.760 --> 00:45:03.870 align:middle line:90%
maybe not quite as well.

00:45:03.870 --> 00:45:08.220 align:middle line:84%
But to within all the
experimental uncertainties,

00:45:08.220 --> 00:45:10.090 align:middle line:90%
it really does a good job.

00:45:10.090 --> 00:45:13.350 align:middle line:84%
So the-fully coupled model
doesn't make much difference--

00:45:13.350 --> 00:45:16.590 align:middle line:84%
that should say difference,
not different, difference--

00:45:16.590 --> 00:45:18.660 align:middle line:84%
because 30 minutes,
again, is much longer

00:45:18.660 --> 00:45:19.980 align:middle line:90%
than the time scale for TED.

00:45:19.980 --> 00:45:21.720 align:middle line:84%
At 1,000 degrees
with this dose, I'm

00:45:21.720 --> 00:45:26.040 align:middle line:84%
guessing TED time scale
is probably less than a

00:45:26.040 --> 00:45:26.890 align:middle line:90%
second or so.

00:45:26.890 --> 00:45:30.450 align:middle line:84%
And in fact, if you
go on to slide 25,

00:45:30.450 --> 00:45:32.910 align:middle line:84%
we can even figure out
roughly what it is.

00:45:32.910 --> 00:45:38.100 align:middle line:84%
At 1,000 degrees, this
was for 1e14 phosphorus.

00:45:38.100 --> 00:45:42.460 align:middle line:84%
At 40 keV, TED is
less than a second.

00:45:42.460 --> 00:45:47.130 align:middle line:84%
So for 2.6e14, again,
it's 2.6 times that,

00:45:47.130 --> 00:45:49.892 align:middle line:84%
almost the same range,
not much difference.

00:45:49.892 --> 00:45:51.850 align:middle line:84%
So we're talking on the
order of a few seconds.

00:45:51.850 --> 00:45:53.973 align:middle line:84%
So a 30-minute
anneal, clearly, TED

00:45:53.973 --> 00:45:55.390 align:middle line:84%
is not going to
be very important.

00:45:55.390 --> 00:45:56.880 align:middle line:84%
That's why you get
the same results.

00:45:56.880 --> 00:45:58.963 align:middle line:84%
But this is a sanity check
you can do with SUPREM.

00:45:58.963 --> 00:46:01.440 align:middle line:84%
Make sure you get the same
result for that 30-minute anneal

00:46:01.440 --> 00:46:04.140 align:middle line:90%
with PD.Fermi and PD.full.

00:46:04.140 --> 00:46:06.240 align:middle line:84%
If you don't, then
there's something

00:46:06.240 --> 00:46:11.340 align:middle line:84%
missing in your understanding
of what SUPREM is doing.

00:46:11.340 --> 00:46:12.555 align:middle line:90%
So there's a simple example.

00:46:12.555 --> 00:46:14.985 align:middle line:90%


00:46:14.985 --> 00:46:16.360 align:middle line:84%
Now let's do
something different.

00:46:16.360 --> 00:46:19.630 align:middle line:84%
On slide 26, instead of
1,000 degrees for 30 minutes,

00:46:19.630 --> 00:46:23.710 align:middle line:84%
I'm going to do ten seconds,
1,000 degrees for ten seconds.

00:46:23.710 --> 00:46:26.560 align:middle line:84%
OK, now you're in a range
where you can imagine there

00:46:26.560 --> 00:46:29.560 align:middle line:90%
might be some TED effects.

00:46:29.560 --> 00:46:32.890 align:middle line:84%
And this is the
simulation we're getting.

00:46:32.890 --> 00:46:36.790 align:middle line:84%
The as-implanted here
is shown in the black.

00:46:36.790 --> 00:46:39.130 align:middle line:84%
And I believe this was
implanted with a Monte Carlo.

00:46:39.130 --> 00:46:41.200 align:middle line:84%
In fact, you can tell
it's Monte Carlo because,

00:46:41.200 --> 00:46:43.750 align:middle line:84%
see all this jaggedness
in the as-implanted?

00:46:43.750 --> 00:46:46.160 align:middle line:84%
You'd never get that out of
an analytic solution, right?

00:46:46.160 --> 00:46:48.160 align:middle line:84%
The jaggedness comes from
the statistical nature

00:46:48.160 --> 00:46:49.160 align:middle line:90%
of Monte Carlo.

00:46:49.160 --> 00:46:52.700 align:middle line:84%
So that's the Monte Carlo
as-implanted in black.

00:46:52.700 --> 00:46:57.440 align:middle line:84%
PD.Fermi, which does no TED,
shows not very much motion

00:46:57.440 --> 00:47:01.040 align:middle line:84%
of the arsenic for
a 10-second RTA.

00:47:01.040 --> 00:47:04.970 align:middle line:84%
PD.full you get a fair
amount of broadening.

00:47:04.970 --> 00:47:07.490 align:middle line:84%
So that's got the
TED built into it.

00:47:07.490 --> 00:47:10.820 align:middle line:84%
Now, exactly which one is more
accurate, I really can't say.

00:47:10.820 --> 00:47:12.710 align:middle line:84%
In fact, my experience
with arsenic

00:47:12.710 --> 00:47:15.200 align:middle line:84%
has been on our rapid
thermal anneals,

00:47:15.200 --> 00:47:16.940 align:middle line:84%
that SUPREM tends
to overestimate

00:47:16.940 --> 00:47:18.410 align:middle line:84%
a little bit the
amount of motion

00:47:18.410 --> 00:47:20.900 align:middle line:84%
compared to what we see
by SIMS, if you actually

00:47:20.900 --> 00:47:24.087 align:middle line:84%
do a SIMS profile of
1,000 degree 10 second.

00:47:24.087 --> 00:47:25.670 align:middle line:84%
Of course, there's
always the question

00:47:25.670 --> 00:47:27.590 align:middle line:84%
of how well is your
RTA calibrated.

00:47:27.590 --> 00:47:29.630 align:middle line:84%
Rapid thermal annealing
machines are extremely

00:47:29.630 --> 00:47:31.787 align:middle line:90%
difficult to calibrate.

00:47:31.787 --> 00:47:33.620 align:middle line:84%
They are nonequilibrium
environments, right?

00:47:33.620 --> 00:47:35.100 align:middle line:84%
It's not like a hot
furnace where everything's

00:47:35.100 --> 00:47:35.990 align:middle line:90%
the same temperature.

00:47:35.990 --> 00:47:38.090 align:middle line:84%
The wafer is the only
thing that gets hot.

00:47:38.090 --> 00:47:40.490 align:middle line:84%
And measuring its temperature
is kind of an art.

00:47:40.490 --> 00:47:41.870 align:middle line:90%
So it's hard to say.

00:47:41.870 --> 00:47:44.720 align:middle line:84%
So you have to be
careful, and typically

00:47:44.720 --> 00:47:47.720 align:middle line:84%
when you're doing rapid thermal
annealing and simulating TED,

00:47:47.720 --> 00:47:50.510 align:middle line:84%
you want to compare it to a
couple of experimental results

00:47:50.510 --> 00:47:52.190 align:middle line:84%
just to make sure
that it makes sense.

00:47:52.190 --> 00:47:54.090 align:middle line:84%
Now, I can make
this PD.full look

00:47:54.090 --> 00:47:57.780 align:middle line:84%
like whatever I want by changing
some of the internal parameters

00:47:57.780 --> 00:48:00.120 align:middle line:90%
in the SUPREM-IV simulator.

00:48:00.120 --> 00:48:08.010 align:middle line:84%
If I change things like the
diffusivity of the interstitials

00:48:08.010 --> 00:48:11.350 align:middle line:84%
and vacancies, I can change
what this profile looks like.

00:48:11.350 --> 00:48:13.110 align:middle line:90%
So you have some latitude there.

00:48:13.110 --> 00:48:17.730 align:middle line:84%
This is using default parameters
that are built into SUPREM-IV.

00:48:17.730 --> 00:48:20.820 align:middle line:90%


00:48:20.820 --> 00:48:25.290 align:middle line:84%
Let me go on slide 27 to
another related example, where

00:48:25.290 --> 00:48:26.700 align:middle line:90%
we're going to talk about how--

00:48:26.700 --> 00:48:29.250 align:middle line:84%
we talked last time about
some clever experiments

00:48:29.250 --> 00:48:32.042 align:middle line:84%
that have been done at the IEDM,
where the order of the anneals--

00:48:32.042 --> 00:48:33.750 align:middle line:84%
we have the exact same
anneals, but we're

00:48:33.750 --> 00:48:35.208 align:middle line:84%
going to reverse
the order which we

00:48:35.208 --> 00:48:39.270 align:middle line:84%
do them makes a difference
because that's going to dissolve

00:48:39.270 --> 00:48:41.920 align:middle line:90%
a lot of 311 defects.

00:48:41.920 --> 00:48:44.340 align:middle line:84%
We're going to show how SUPREM
can actually simulate that.

00:48:44.340 --> 00:48:46.980 align:middle line:84%
And first, I'm going
to just remind you

00:48:46.980 --> 00:48:50.670 align:middle line:84%
what the usual order of making
a MOSFET is just from last time.

00:48:50.670 --> 00:48:52.110 align:middle line:90%
Usually, you start with a wafer.

00:48:52.110 --> 00:48:53.220 align:middle line:90%
You do your isolation.

00:48:53.220 --> 00:48:56.040 align:middle line:84%
This could be your
shallow trench isolation

00:48:56.040 --> 00:48:57.900 align:middle line:90%
we talk about as oxide.

00:48:57.900 --> 00:48:59.400 align:middle line:84%
Oop, that didn't
come out very well.

00:48:59.400 --> 00:49:04.650 align:middle line:84%
I'm going to implant
the boron profile.

00:49:04.650 --> 00:49:05.850 align:middle line:90%
This is an n MOSFET.

00:49:05.850 --> 00:49:11.880 align:middle line:84%
I'm going to implant that early
on the super steep retrograde.

00:49:11.880 --> 00:49:16.540 align:middle line:84%
Grow the gate oxide, so
we're growing the gate oxide.

00:49:16.540 --> 00:49:21.235 align:middle line:84%
Form the polysilicon gate
by deposition and etching.

00:49:21.235 --> 00:49:24.960 align:middle line:90%


00:49:24.960 --> 00:49:27.540 align:middle line:84%
The source drain extensions
are now implanted.

00:49:27.540 --> 00:49:30.240 align:middle line:84%
Now, the source drain extensions
bring with them-- remember,

00:49:30.240 --> 00:49:33.540 align:middle line:84%
we talked about the reverse
short channel effect.

00:49:33.540 --> 00:49:37.680 align:middle line:84%
They're going to introduce a
certain number of 311 defects

00:49:37.680 --> 00:49:40.140 align:middle line:84%
that are going to cause
TED of the boron that's

00:49:40.140 --> 00:49:43.050 align:middle line:90%
underneath here.

00:49:43.050 --> 00:49:44.370 align:middle line:90%
Put in the spacers.

00:49:44.370 --> 00:49:46.068 align:middle line:84%
Now, the spacers,
if they're nitride--

00:49:46.068 --> 00:49:48.360 align:middle line:84%
a lot of people today are
using nitride and not oxide--

00:49:48.360 --> 00:49:51.270 align:middle line:84%
if they're nitride and
they're LPCVD nitride, that's

00:49:51.270 --> 00:49:54.060 align:middle line:84%
a pretty high-temperature
process, about 800 degrees, one

00:49:54.060 --> 00:49:57.600 align:middle line:84%
of the worst temperatures
you can possibly use for TED.

00:49:57.600 --> 00:49:58.380 align:middle line:90%
Why is that?

00:49:58.380 --> 00:50:01.230 align:middle line:84%
Well, we saw that the time
that TED lasts at 800,

00:50:01.230 --> 00:50:04.530 align:middle line:90%
it can be quite long.

00:50:04.530 --> 00:50:07.660 align:middle line:84%
And CI over CI star
can be quite large.

00:50:07.660 --> 00:50:10.020 align:middle line:84%
So an hour at 800
can cause a lot

00:50:10.020 --> 00:50:12.120 align:middle line:90%
of transient-enhanced diffusion.

00:50:12.120 --> 00:50:15.300 align:middle line:84%
And then after that, typically
after you make the spacers,

00:50:15.300 --> 00:50:18.210 align:middle line:84%
you do this deep source
drain implant here

00:50:18.210 --> 00:50:19.900 align:middle line:90%
for the contact regions.

00:50:19.900 --> 00:50:22.350 align:middle line:84%
And then you do a final
rapid thermal anneal,

00:50:22.350 --> 00:50:26.760 align:middle line:84%
usually 1,000 to 1,050, maybe
10 to 30 seconds, something

00:50:26.760 --> 00:50:27.610 align:middle line:90%
in that range.

00:50:27.610 --> 00:50:31.590 align:middle line:84%
So the important thermal steps
are, this nitride at 900,

00:50:31.590 --> 00:50:34.230 align:middle line:84%
this nitride thermal
budget at 800,

00:50:34.230 --> 00:50:36.990 align:middle line:84%
and then a rapid thermal
anneal at around 1,000.

00:50:36.990 --> 00:50:40.020 align:middle line:84%
And now we're going to compare
with SUPREM, how SUPREM thinks

00:50:40.020 --> 00:50:45.660 align:middle line:90%
in 1D sense this would go.

00:50:45.660 --> 00:50:49.500 align:middle line:84%
So we're going to just
look at the effect of TED

00:50:49.500 --> 00:50:51.510 align:middle line:84%
just on the arsenic
diffusion itself.

00:50:51.510 --> 00:50:54.360 align:middle line:84%
We're not going to look at the
effect on the boron diffusivity.

00:50:54.360 --> 00:50:56.710 align:middle line:84%
That would require a
two-dimensional simulation.

00:50:56.710 --> 00:50:59.670 align:middle line:84%
So this is a simulation of an
arsenic source drain extension

00:50:59.670 --> 00:51:03.810 align:middle line:84%
implant and diffusing it
using the usual order, which

00:51:03.810 --> 00:51:08.790 align:middle line:84%
is 800 degrees C step for the
nitride deposition, followed

00:51:08.790 --> 00:51:13.650 align:middle line:84%
by a deep source drain, and
then followed by 1,000 degrees

00:51:13.650 --> 00:51:17.220 align:middle line:84%
C 5-second RTA to
activate everything.

00:51:17.220 --> 00:51:19.430 align:middle line:84%
So here's the arsenic
Monte Carlo implant.

00:51:19.430 --> 00:51:21.800 align:middle line:90%
And you can see on this scale--

00:51:21.800 --> 00:51:23.810 align:middle line:84%
this is the distance
in microns and the--

00:51:23.810 --> 00:51:27.200 align:middle line:84%
they didn't use
a very fine grid.

00:51:27.200 --> 00:51:31.280 align:middle line:84%
Good enough to get this profile,
but for the as-implanted,

00:51:31.280 --> 00:51:32.870 align:middle line:84%
you can see it's
kind of ugly looking.

00:51:32.870 --> 00:51:34.970 align:middle line:84%
And that's part of the
reason the grid was

00:51:34.970 --> 00:51:35.990 align:middle line:90%
a little bit too coarse.

00:51:35.990 --> 00:51:37.820 align:middle line:84%
But again, with
Monte Carlo, we were

00:51:37.820 --> 00:51:40.250 align:middle line:84%
trying to speed up the
processing a little.

00:51:40.250 --> 00:51:46.190 align:middle line:84%
So here's 2 keV, very
shallow peaks, at 1e15.

00:51:46.190 --> 00:51:52.480 align:middle line:84%
And then the blue line is 800
degrees, 30 minutes anneal.

00:51:52.480 --> 00:51:54.970 align:middle line:84%
And then the red line is
800 degrees, 30 minutes,

00:51:54.970 --> 00:51:57.190 align:middle line:84%
followed by a rapid
thermal anneal at 1,000

00:51:57.190 --> 00:52:00.470 align:middle line:84%
for five seconds,
so 1D simulation.

00:52:00.470 --> 00:52:03.100 align:middle line:84%
So almost all the
diffusion really

00:52:03.100 --> 00:52:06.230 align:middle line:84%
takes place at the
800 degree 30 minutes.

00:52:06.230 --> 00:52:07.480 align:middle line:90%
And that's because of TED.

00:52:07.480 --> 00:52:11.875 align:middle line:84%
That's not ordinary 800 degrees
C. So in order to model this,

00:52:11.875 --> 00:52:14.020 align:middle line:90%
this must be a PD.full.

00:52:14.020 --> 00:52:15.580 align:middle line:84%
So it must be
taking into account

00:52:15.580 --> 00:52:18.377 align:middle line:90%
the transit-enhanced diffusion.

00:52:18.377 --> 00:52:19.210 align:middle line:90%
Well, this is trans.

00:52:19.210 --> 00:52:19.710 align:middle line:90%
I'm sorry.

00:52:19.710 --> 00:52:20.475 align:middle line:90%
This is PD.trans.

00:52:20.475 --> 00:52:21.850 align:middle line:84%
You can either
use trans or full.

00:52:21.850 --> 00:52:24.923 align:middle line:90%
This particular one is PD.trans.

00:52:24.923 --> 00:52:27.340 align:middle line:84%
OK, so that's what it looks
like, very little contribution

00:52:27.340 --> 00:52:28.240 align:middle line:90%
of the RTA.

00:52:28.240 --> 00:52:30.850 align:middle line:84%
And your junction depth
here is about 0.1 micron.

00:52:30.850 --> 00:52:33.640 align:middle line:90%
That's what this predicts.

00:52:33.640 --> 00:52:34.960 align:middle line:90%
So why is that?

00:52:34.960 --> 00:52:38.470 align:middle line:84%
If you look on slide
29, this is a plot--

00:52:38.470 --> 00:52:40.000 align:middle line:84%
SUPREM, in addition
to the dopants,

00:52:40.000 --> 00:52:42.830 align:middle line:84%
you can output the
interstitials and vacancies.

00:52:42.830 --> 00:52:47.170 align:middle line:84%
So here's a normalized
concentration versus depth.

00:52:47.170 --> 00:52:51.710 align:middle line:84%
And the blue line here is for
CI over CI star at 800 degrees.

00:52:51.710 --> 00:52:57.820 align:middle line:84%
And so you can see, CI over
CI star after this anneal,

00:52:57.820 --> 00:53:00.440 align:middle line:84%
at the 800-degree anneal,
that is, it's pretty large.

00:53:00.440 --> 00:53:03.200 align:middle line:84%
It's somewhere between 20
and 40 and near the surface.

00:53:03.200 --> 00:53:05.345 align:middle line:90%
It's pretty big.

00:53:05.345 --> 00:53:06.220 align:middle line:90%
That's the blue line.

00:53:06.220 --> 00:53:08.137 align:middle line:84%
The red line, which I
apologize you can't see.

00:53:08.137 --> 00:53:11.200 align:middle line:84%
You have to write it on your--
it's the same as your x-axis,

00:53:11.200 --> 00:53:11.830 align:middle line:90%
basically.

00:53:11.830 --> 00:53:13.472 align:middle line:90%
The red line is just about one.

00:53:13.472 --> 00:53:14.930 align:middle line:84%
You can't even see
it on the scale.

00:53:14.930 --> 00:53:18.770 align:middle line:84%
So CI over CI star
at 1,000 degrees,

00:53:18.770 --> 00:53:22.040 align:middle line:84%
after five seconds is one, which
there isn't much enhancement

00:53:22.040 --> 00:53:22.610 align:middle line:90%
left.

00:53:22.610 --> 00:53:23.480 align:middle line:90%
And we saw that.

00:53:23.480 --> 00:53:27.560 align:middle line:84%
Remember, the enhancement time,
the amount of time that it lasts

00:53:27.560 --> 00:53:28.590 align:middle line:90%
is relatively short.

00:53:28.590 --> 00:53:30.920 align:middle line:90%
So this is after five seconds.

00:53:30.920 --> 00:53:32.420 align:middle line:90%
So TED is already--

00:53:32.420 --> 00:53:35.533 align:middle line:84%
the interstitial concentration--
the 311s have all dissolved.

00:53:35.533 --> 00:53:36.950 align:middle line:84%
And the interstitial
concentration

00:53:36.950 --> 00:53:39.290 align:middle line:90%
has gone back to CI star.

00:53:39.290 --> 00:53:41.480 align:middle line:84%
So after five
seconds, we still have

00:53:41.480 --> 00:53:43.730 align:middle line:84%
a lot of enhancement
at 800 degrees,

00:53:43.730 --> 00:53:49.960 align:middle line:84%
and that's why we get all that
TED in the 800-degree C profile.

00:53:49.960 --> 00:53:52.050 align:middle line:84%
So now, on slide 30,
we're going to do

00:53:52.050 --> 00:53:54.280 align:middle line:90%
something a little different.

00:53:54.280 --> 00:53:57.390 align:middle line:84%
We're going to activate
the source drain extension

00:53:57.390 --> 00:54:01.140 align:middle line:84%
implant prior to the
nitride spacer at 800.

00:54:01.140 --> 00:54:02.880 align:middle line:84%
So what we're
going to do instead

00:54:02.880 --> 00:54:05.370 align:middle line:84%
of doing the usual put
the nitride down right

00:54:05.370 --> 00:54:07.830 align:middle line:84%
after implanting,
we're going to do

00:54:07.830 --> 00:54:11.470 align:middle line:84%
a 5-second rapid thermal
anneal after implanting.

00:54:11.470 --> 00:54:12.810 align:middle line:90%
So we send it out for implant.

00:54:12.810 --> 00:54:13.770 align:middle line:90%
We bring it back.

00:54:13.770 --> 00:54:19.410 align:middle line:84%
We do a 5-second RTA first,
and then we do another five

00:54:19.410 --> 00:54:20.220 align:middle line:90%
seconds--

00:54:20.220 --> 00:54:23.100 align:middle line:84%
and then we do 800
degrees plus 30 minutes.

00:54:23.100 --> 00:54:24.160 align:middle line:90%
We do that second.

00:54:24.160 --> 00:54:25.710 align:middle line:90%
So we're changing the order.

00:54:25.710 --> 00:54:28.650 align:middle line:84%
And you can see
the red line now is

00:54:28.650 --> 00:54:34.630 align:middle line:84%
after the implant plus 5 seconds
at 1,000, you diffuse this far.

00:54:34.630 --> 00:54:37.740 align:middle line:84%
And then if you add the 830
minutes, it only goes that far.

00:54:37.740 --> 00:54:40.590 align:middle line:84%
It doesn't go very far
because five seconds is

00:54:40.590 --> 00:54:43.710 align:middle line:84%
1,000 is really enough to
dissolve all the 311s, right?

00:54:43.710 --> 00:54:48.790 align:middle line:84%
The enhancement-- the
TED time at 1,000 degrees

00:54:48.790 --> 00:54:50.360 align:middle line:90%
is only a couple of seconds.

00:54:50.360 --> 00:54:51.880 align:middle line:90%
So I dissolve all the 311s.

00:54:51.880 --> 00:54:54.010 align:middle line:84%
Then you put it back
in the furnace at 800,

00:54:54.010 --> 00:54:55.120 align:middle line:90%
and you don't get--

00:54:55.120 --> 00:54:57.100 align:middle line:84%
this is just normal 800
degrees C diffusion.

00:54:57.100 --> 00:55:00.580 align:middle line:84%
There's not many CI over CI*s
now been reduced because I got

00:55:00.580 --> 00:55:01.870 align:middle line:90%
rid of all those 311s.

00:55:01.870 --> 00:55:05.380 align:middle line:84%
So the junction depth now,
here, instead of being out here

00:55:05.380 --> 00:55:08.540 align:middle line:90%
at 0.1, is only 0.07.

00:55:08.540 --> 00:55:13.460 align:middle line:84%
So the exact same amount of time
that the wafer spent in the RTA

00:55:13.460 --> 00:55:16.310 align:middle line:84%
and in the furnace is just that
the order of the operations

00:55:16.310 --> 00:55:18.240 align:middle line:90%
was changed.

00:55:18.240 --> 00:55:20.400 align:middle line:84%
And this is reduced, the
junction depth is reduced

00:55:20.400 --> 00:55:24.420 align:middle line:84%
because CI over CI star is
reduced by about 3x during

00:55:24.420 --> 00:55:26.650 align:middle line:90%
the 1,000-degree C step.

00:55:26.650 --> 00:55:29.220 align:middle line:84%
So this is something--
these are all simulations.

00:55:29.220 --> 00:55:33.000 align:middle line:84%
SUPREM can simulate the
fact that 311s are generated

00:55:33.000 --> 00:55:35.373 align:middle line:84%
by the damage and
that they dissolve

00:55:35.373 --> 00:55:37.290 align:middle line:84%
at different temperatures,
at different rates.

00:55:37.290 --> 00:55:41.040 align:middle line:84%
And then so it can take into
account these types of effects.

00:55:41.040 --> 00:55:43.140 align:middle line:84%
Again, it's using
the trans model.

00:55:43.140 --> 00:55:44.772 align:middle line:84%
The accuracy, of
course, you always

00:55:44.772 --> 00:55:46.980 align:middle line:84%
take with a grain of salt,
whether the junction depth

00:55:46.980 --> 00:55:50.810 align:middle line:84%
is really 0.06, 0.04, I
wouldn't put my life on it,

00:55:50.810 --> 00:55:53.310 align:middle line:84%
to be honest, because there's
a lot of parameters in SUPREM.

00:55:53.310 --> 00:55:56.250 align:middle line:84%
But the point is, you can
fit your data-- assuming

00:55:56.250 --> 00:55:58.110 align:middle line:84%
you get some data,
you can fit data

00:55:58.110 --> 00:56:01.350 align:middle line:84%
that shows the effect of the
order of the different implants.

00:56:01.350 --> 00:56:02.960 align:middle line:84%
There's enough
physics built into it.

00:56:02.960 --> 00:56:04.710 align:middle line:84%
You just have to get
the right parameters.

00:56:04.710 --> 00:56:07.790 align:middle line:90%


00:56:07.790 --> 00:56:12.830 align:middle line:84%
So the final process, just
to show that what we did

00:56:12.830 --> 00:56:14.690 align:middle line:84%
is the extension
implant followed

00:56:14.690 --> 00:56:18.710 align:middle line:84%
by 5-second RTA and 1,000
high-temperature nitride spacer

00:56:18.710 --> 00:56:21.020 align:middle line:84%
at 800 and then
another 5-second RTA.

00:56:21.020 --> 00:56:23.030 align:middle line:84%
The reason I needed
to add the last RTA

00:56:23.030 --> 00:56:25.040 align:middle line:84%
is to activate the
deep source drain.

00:56:25.040 --> 00:56:27.080 align:middle line:84%
Remember, the deep
source drain goes in last

00:56:27.080 --> 00:56:28.490 align:middle line:90%
after the nitride spacer.

00:56:28.490 --> 00:56:32.900 align:middle line:84%
So this is five seconds at
1,800, five seconds at 1,000.

00:56:32.900 --> 00:56:34.580 align:middle line:90%
This is what it would look like.

00:56:34.580 --> 00:56:36.410 align:middle line:84%
The final five seconds
at 1,000 really

00:56:36.410 --> 00:56:38.600 align:middle line:84%
doesn't contribute
much to further motion.

00:56:38.600 --> 00:56:41.210 align:middle line:84%
It's already done
most of its motion

00:56:41.210 --> 00:56:44.930 align:middle line:84%
because TED, at that
point, is completely over.

00:56:44.930 --> 00:56:48.630 align:middle line:84%
And if you've done it the
usual order, 800 degrees,

00:56:48.630 --> 00:56:51.500 align:middle line:84%
30-minutes spacer, plus 5
seconds to anneal everything,

00:56:51.500 --> 00:56:53.070 align:middle line:90%
you get this junction depth.

00:56:53.070 --> 00:56:57.947 align:middle line:84%
So this the SUPREM
predicts that reversing

00:56:57.947 --> 00:56:59.780 align:middle line:84%
the order of the anneals
makes a difference.

00:56:59.780 --> 00:57:02.510 align:middle line:84%
Again, it's something you'd have
to check experimentally just

00:57:02.510 --> 00:57:03.020 align:middle line:90%
to be sure.

00:57:03.020 --> 00:57:05.910 align:middle line:90%


00:57:05.910 --> 00:57:07.890 align:middle line:90%
OK, so that was a TED example.

00:57:07.890 --> 00:57:10.230 align:middle line:84%
And then for the
fourth example, this

00:57:10.230 --> 00:57:15.060 align:middle line:84%
will be the only example I'll
do where we do two-dimensional,

00:57:15.060 --> 00:57:16.590 align:middle line:90%
a two-dimensional simulation.

00:57:16.590 --> 00:57:18.870 align:middle line:84%
And this I took this right
from the SUPREM manual.

00:57:18.870 --> 00:57:20.250 align:middle line:90%
So you can run this yourself.

00:57:20.250 --> 00:57:22.333 align:middle line:84%
This particular example
is not one that I made up.

00:57:22.333 --> 00:57:24.513 align:middle line:84%
I took it out of
the example file,

00:57:24.513 --> 00:57:25.680 align:middle line:90%
and this is on the computer.

00:57:25.680 --> 00:57:28.980 align:middle line:84%
This example is one
of the canned examples

00:57:28.980 --> 00:57:31.250 align:middle line:90%
that comes with SUPREM-IV.

00:57:31.250 --> 00:57:33.910 align:middle line:84%
It's a 200-nanometer
gate length,

00:57:33.910 --> 00:57:36.660 align:middle line:84%
so that's 0.2 micron
gate length and MOSFET.

00:57:36.660 --> 00:57:38.280 align:middle line:90%
It's kind of old fashioned now.

00:57:38.280 --> 00:57:40.435 align:middle line:84%
But it uses something called
self-aligned silicide,

00:57:40.435 --> 00:57:42.060 align:middle line:84%
and we're going to
talk about silicides

00:57:42.060 --> 00:57:42.990 align:middle line:90%
in the next few lectures.

00:57:42.990 --> 00:57:43.907 align:middle line:90%
So you'll get an idea.

00:57:43.907 --> 00:57:47.370 align:middle line:84%
And I've put the [? input ?]
file and columns.

00:57:47.370 --> 00:57:49.493 align:middle line:84%
So this is the first
part of the file,

00:57:49.493 --> 00:57:50.660 align:middle line:90%
and this is the second part.

00:57:50.660 --> 00:57:52.660 align:middle line:84%
Again, if you want to see
the [? actual ?] file,

00:57:52.660 --> 00:57:56.480 align:middle line:90%
it's in the SUPREM-IV directory.

00:57:56.480 --> 00:57:58.220 align:middle line:90%
So this is TSUPREM-4.

00:57:58.220 --> 00:58:01.730 align:middle line:84%
So example, here's the mesh
using a fairly coarse grid,

00:58:01.730 --> 00:58:05.090 align:middle line:90%
grid dot fac of 0.9.

00:58:05.090 --> 00:58:08.840 align:middle line:84%
You can also define the mesh
in different directions,

00:58:08.840 --> 00:58:12.090 align:middle line:84%
in the y direction,
in the x direction,

00:58:12.090 --> 00:58:16.790 align:middle line:84%
so a little more sophisticated
definition of the grid.

00:58:16.790 --> 00:58:19.250 align:middle line:84%
We start out by
growing the gate oxide.

00:58:19.250 --> 00:58:21.800 align:middle line:90%
So here's 850, 25 minutes.

00:58:21.800 --> 00:58:25.070 align:middle line:84%
And it's in dry O2 plus
a little bit of HCl.

00:58:25.070 --> 00:58:28.130 align:middle line:90%
So there's an HCl oxidation.

00:58:28.130 --> 00:58:29.630 align:middle line:84%
And then you can
plot the structure

00:58:29.630 --> 00:58:32.960 align:middle line:84%
to see what it looks like
after gate oxidation.

00:58:32.960 --> 00:58:37.400 align:middle line:84%
And this says, whenever you see
the word source, what that says

00:58:37.400 --> 00:58:38.070 align:middle line:90%
is--

00:58:38.070 --> 00:58:39.590 align:middle line:84%
and then you have
the file name that

00:58:39.590 --> 00:58:43.160 align:middle line:84%
says, take all the commands from
that file name and run them now.

00:58:43.160 --> 00:58:46.325 align:middle line:90%
So TSUPREM-IV, in order to--

00:58:46.325 --> 00:58:48.200 align:middle line:84%
let's say you do the
same operation in SUPREM

00:58:48.200 --> 00:58:49.100 align:middle line:90%
over and over again.

00:58:49.100 --> 00:58:50.180 align:middle line:90%
You always do a plot.

00:58:50.180 --> 00:58:52.070 align:middle line:84%
You want to do several
different plots.

00:58:52.070 --> 00:58:55.010 align:middle line:84%
Rather than putting all those
plot commands in the main file

00:58:55.010 --> 00:58:57.800 align:middle line:84%
over and over again,
you create sub files.

00:58:57.800 --> 00:59:03.230 align:middle line:84%
And this file called
S4EX10P.input is just

00:59:03.230 --> 00:59:05.240 align:middle line:84%
a series of commands
that defines the colors

00:59:05.240 --> 00:59:06.390 align:middle line:90%
and things like that.

00:59:06.390 --> 00:59:08.810 align:middle line:84%
So it enables you to
call this file whenever

00:59:08.810 --> 00:59:11.300 align:middle line:90%
you want it to create a plot.

00:59:11.300 --> 00:59:14.370 align:middle line:84%
So it's a way of cleaning
up your SUPREM input file.

00:59:14.370 --> 00:59:16.620 align:middle line:84%
So if you want to know what
this particular file does,

00:59:16.620 --> 00:59:19.650 align:middle line:84%
you have to go look
at that command file.

00:59:19.650 --> 00:59:22.740 align:middle line:84%
Then you deposit some materials
or depositing polysilicon.

00:59:22.740 --> 00:59:24.090 align:middle line:90%
You tell it the thickness.

00:59:24.090 --> 00:59:26.890 align:middle line:84%
You're etching the polysilicon
to the right and to the left.

00:59:26.890 --> 00:59:27.855 align:middle line:90%
This is to make a gate.

00:59:27.855 --> 00:59:30.500 align:middle line:90%


00:59:30.500 --> 00:59:31.980 align:middle line:84%
And here you're
calling that file,

00:59:31.980 --> 00:59:35.160 align:middle line:90%
again, that plotting file, OK?

00:59:35.160 --> 00:59:38.370 align:middle line:84%
Now, one of your homework
problems that you just handed in

00:59:38.370 --> 00:59:39.870 align:middle line:90%
was on--

00:59:39.870 --> 00:59:41.880 align:middle line:84%
or we just handed back
to you, homework 3,

00:59:41.880 --> 00:59:42.960 align:middle line:90%
was different methods.

00:59:42.960 --> 00:59:45.420 align:middle line:84%
This is using the
compressed method

00:59:45.420 --> 00:59:48.570 align:middle line:84%
as far as solving for
the oxidation rate goes.

00:59:48.570 --> 00:59:52.930 align:middle line:84%
Here's 850 oxidation in
dry O2 and HCl again.

00:59:52.930 --> 00:59:54.930 align:middle line:90%
So this is what we call re-ox.

00:59:54.930 --> 00:59:59.160 align:middle line:90%
So you formed the gate now.

00:59:59.160 --> 01:00:01.290 align:middle line:84%
So the initial gate
oxidation is just

01:00:01.290 --> 01:00:03.090 align:middle line:90%
to grow a very thin gate oxide.

01:00:03.090 --> 01:00:06.750 align:middle line:84%
You formed the gate,
and you etched it.

01:00:06.750 --> 01:00:08.370 align:middle line:84%
And then, in the
course of etching,

01:00:08.370 --> 01:00:10.252 align:middle line:84%
sometimes you
introduce damage right

01:00:10.252 --> 01:00:12.460 align:middle line:84%
near the corners of where
the channel is going to be.

01:00:12.460 --> 01:00:12.660 align:middle line:90%
Remember?

01:00:12.660 --> 01:00:13.952 align:middle line:90%
This is going to be my channel.

01:00:13.952 --> 01:00:17.760 align:middle line:84%
So you often introduce some
plasma damage down here.

01:00:17.760 --> 01:00:19.230 align:middle line:90%
You SiN up the oxide there.

01:00:19.230 --> 01:00:21.600 align:middle line:84%
You do things that are not
necessarily good for the gate

01:00:21.600 --> 01:00:22.100 align:middle line:90%
oxide.

01:00:22.100 --> 01:00:26.220 align:middle line:84%
So people often, at this point,
will, in this technology,

01:00:26.220 --> 01:00:29.100 align:middle line:84%
say, 0.18 micron technology,
would take the wafer

01:00:29.100 --> 01:00:31.560 align:middle line:84%
at this point, put it back
in the oxidation furnace,

01:00:31.560 --> 01:00:33.660 align:middle line:84%
and do what's
called a gate re-ox.

01:00:33.660 --> 01:00:39.237 align:middle line:84%
And this looks like we're doing
a re-ox here at 850 for 25

01:00:39.237 --> 01:00:39.820 align:middle line:90%
[? minutes. ?]

01:00:39.820 --> 01:00:42.900 align:middle line:84%
So that re-ox is going to help--
if you thinned the oxide at all

01:00:42.900 --> 01:00:44.400 align:middle line:84%
in the course of
your etching, it's

01:00:44.400 --> 01:00:47.190 align:middle line:84%
going to help
boost that back up.

01:00:47.190 --> 01:00:52.800 align:middle line:84%
And it's going to grow a little
oxide along the edge here

01:00:52.800 --> 01:00:54.180 align:middle line:90%
of the polysilicon.

01:00:54.180 --> 01:00:56.940 align:middle line:84%
So it's a way of dealing--
it was introduced

01:00:56.940 --> 01:00:59.460 align:middle line:90%
for reliability considerations.

01:00:59.460 --> 01:01:01.810 align:middle line:84%
Re-ex, as it says,
take the gate,

01:01:01.810 --> 01:01:05.790 align:middle line:84%
put it back in, and
do another oxidation.

01:01:05.790 --> 01:01:08.070 align:middle line:84%
Then you form the
sidewall spacer.

01:01:08.070 --> 01:01:10.020 align:middle line:90%
Here, we're depositing oxide.

01:01:10.020 --> 01:01:14.730 align:middle line:84%
It's using an oxidation--
a deposition process.

01:01:14.730 --> 01:01:18.060 align:middle line:84%
And then you do the deep
source drain implant.

01:01:18.060 --> 01:01:23.438 align:middle line:84%
This is 1e15 energy of
60 keVs, fairly deep.

01:01:23.438 --> 01:01:25.230 align:middle line:84%
Then you're going to
deposit some titanium.

01:01:25.230 --> 01:01:26.855 align:middle line:84%
I won't go through
the details of this.

01:01:26.855 --> 01:01:30.018 align:middle line:84%
But in the next few lectures,
we'll talk about the fact that--

01:01:30.018 --> 01:01:31.560 align:middle line:84%
when we get to the
silicide lecture--

01:01:31.560 --> 01:01:33.985 align:middle line:84%
you can take metals,
put them on silicon,

01:01:33.985 --> 01:01:35.610 align:middle line:84%
and react them at a
certain temperature

01:01:35.610 --> 01:01:37.502 align:middle line:90%
and form a metallic phase.

01:01:37.502 --> 01:01:38.460 align:middle line:90%
It's called a silicide.

01:01:38.460 --> 01:01:42.570 align:middle line:84%
This is titanium disilicide,
which forms a good contact.

01:01:42.570 --> 01:01:45.220 align:middle line:84%
And then we look at
the final structure.

01:01:45.220 --> 01:01:47.470 align:middle line:84%
So that's the file, and you
can go ahead and run that.

01:01:47.470 --> 01:01:48.845 align:middle line:84%
And let me show
you some examples

01:01:48.845 --> 01:01:50.700 align:middle line:90%
of what comes out of that.

01:01:50.700 --> 01:01:53.460 align:middle line:84%
Oh, actually, this
slide, number 33,

01:01:53.460 --> 01:01:55.770 align:middle line:84%
remember, I was saying you
wanted to repeat this over

01:01:55.770 --> 01:01:57.062 align:middle line:90%
and over again, these commands?

01:01:57.062 --> 01:02:00.600 align:middle line:84%
This was that file,
S4EX10P.input.

01:02:00.600 --> 01:02:02.790 align:middle line:84%
This is just a
plotting sequence file

01:02:02.790 --> 01:02:07.260 align:middle line:84%
that you use over and over again
that tells it what colors to use

01:02:07.260 --> 01:02:10.810 align:middle line:84%
and how to label things
according to what material is.

01:02:10.810 --> 01:02:14.430 align:middle line:84%
So rather than type this in
every time in your SUPREM-IV,

01:02:14.430 --> 01:02:16.050 align:middle line:84%
you can put it in
a separate file.

01:02:16.050 --> 01:02:19.180 align:middle line:90%
That's just for your reference.

01:02:19.180 --> 01:02:21.390 align:middle line:90%
So let's go to slide 34.

01:02:21.390 --> 01:02:22.830 align:middle line:84%
This is from running
that example.

01:02:22.830 --> 01:02:24.705 align:middle line:84%
After gate oxidation,
what does it look like?

01:02:24.705 --> 01:02:27.810 align:middle line:84%
Well, you have an xy
structure, so y is in depth.

01:02:27.810 --> 01:02:30.750 align:middle line:84%
And there's a certain gate
oxide grown everywhere

01:02:30.750 --> 01:02:32.850 align:middle line:90%
across on the structure.

01:02:32.850 --> 01:02:35.310 align:middle line:90%
That's relatively simple.

01:02:35.310 --> 01:02:38.280 align:middle line:84%
After gate patterning, you
have deposited this green layer

01:02:38.280 --> 01:02:40.080 align:middle line:84%
everywhere and
then etched it off

01:02:40.080 --> 01:02:43.000 align:middle line:84%
everywhere to the
right of this one line.

01:02:43.000 --> 01:02:44.940 align:middle line:84%
So now, that's what
the polysilicon gate

01:02:44.940 --> 01:02:47.070 align:middle line:84%
looks like with the
gate oxide underneath it

01:02:47.070 --> 01:02:49.860 align:middle line:90%
after gate patterning, OK?

01:02:49.860 --> 01:02:51.940 align:middle line:84%
And notice, it
doesn't model etching

01:02:51.940 --> 01:02:53.320 align:middle line:90%
in any sophisticated way.

01:02:53.320 --> 01:02:55.150 align:middle line:84%
You just tell it
where to cut it off.

01:02:55.150 --> 01:02:58.150 align:middle line:84%
So it's not modeling any shape
effects of the etch or anything

01:02:58.150 --> 01:02:58.780 align:middle line:90%
like that.

01:02:58.780 --> 01:03:00.575 align:middle line:84%
That's not that
type of a program.

01:03:00.575 --> 01:03:02.200 align:middle line:84%
We'll talk more about
that when we talk

01:03:02.200 --> 01:03:05.240 align:middle line:90%
about how to model etching.

01:03:05.240 --> 01:03:06.952 align:middle line:84%
After gate re-ox,
remember, I said

01:03:06.952 --> 01:03:08.660 align:middle line:84%
we're going to put it
back in the furnace

01:03:08.660 --> 01:03:12.020 align:middle line:84%
and subject it to a step
of 850 for 25 minutes

01:03:12.020 --> 01:03:14.990 align:middle line:84%
to oxidize all around and
to beef up this oxide.

01:03:14.990 --> 01:03:18.320 align:middle line:84%
But interestingly, look what
it's done to the gate oxide.

01:03:18.320 --> 01:03:19.628 align:middle line:90%
You see what it's done.

01:03:19.628 --> 01:03:21.170 align:middle line:84%
There's like a bird's
beaking effect.

01:03:21.170 --> 01:03:24.590 align:middle line:84%
Some of the oxidant has diffused
underneath the polysilicon

01:03:24.590 --> 01:03:25.520 align:middle line:90%
and diffused it.

01:03:25.520 --> 01:03:27.950 align:middle line:84%
And you've got a little
thicker oxide now here

01:03:27.950 --> 01:03:29.810 align:middle line:84%
on this part underneath
the gate compared

01:03:29.810 --> 01:03:31.730 align:middle line:90%
to the center of the gate.

01:03:31.730 --> 01:03:33.290 align:middle line:84%
That's not necessarily
a good thing

01:03:33.290 --> 01:03:35.062 align:middle line:84%
if it's too thick
here because what

01:03:35.062 --> 01:03:36.770 align:middle line:84%
do we know about the
gate oxide thickness

01:03:36.770 --> 01:03:39.450 align:middle line:84%
determines the threshold
voltage in the device.

01:03:39.450 --> 01:03:42.620 align:middle line:84%
So if I have a thicker
gate oxide here than here,

01:03:42.620 --> 01:03:49.255 align:middle line:84%
I'm going to turn on my channel
at different places differently.

01:03:49.255 --> 01:03:50.880 align:middle line:84%
So that's not
necessarily a good thing.

01:03:50.880 --> 01:03:54.340 align:middle line:90%
We want a uniform gate oxide.

01:03:54.340 --> 01:03:59.050 align:middle line:84%
Here, of that same structure
now, after I've formed a spacer,

01:03:59.050 --> 01:04:00.850 align:middle line:90%
here's the oxide spacer.

01:04:00.850 --> 01:04:04.980 align:middle line:84%
And we did a source
drain extension.

01:04:04.980 --> 01:04:05.480 align:middle line:90%
I'm sorry.

01:04:05.480 --> 01:04:07.763 align:middle line:84%
I first did the 5e13
source drain extension.

01:04:07.763 --> 01:04:09.430 align:middle line:84%
Then you formed the
spacer, and then you

01:04:09.430 --> 01:04:11.080 align:middle line:90%
did the deep source drain.

01:04:11.080 --> 01:04:14.560 align:middle line:84%
These contours, by
the way, correspond

01:04:14.560 --> 01:04:16.693 align:middle line:90%
to arsenic in the substrate.

01:04:16.693 --> 01:04:18.610 align:middle line:84%
Each one is a different
arsenic concentration.

01:04:18.610 --> 01:04:19.990 align:middle line:90%
You can see how it's shaped.

01:04:19.990 --> 01:04:23.140 align:middle line:84%
This region here corresponds
to the extension, This.

01:04:23.140 --> 01:04:26.460 align:middle line:90%
Region to the deep source drain.

01:04:26.460 --> 01:04:30.630 align:middle line:84%
This particular simulation uses
PD.Fermi, so the Fermi model,

01:04:30.630 --> 01:04:31.155 align:middle line:90%
very simple.

01:04:31.155 --> 01:04:33.960 align:middle line:90%


01:04:33.960 --> 01:04:36.270 align:middle line:84%
And then after silicidation,
SUPREM doesn't necessarily

01:04:36.270 --> 01:04:37.853 align:middle line:84%
go to a very good
model of siliciding,

01:04:37.853 --> 01:04:39.330 align:middle line:90%
but you see it's reacted.

01:04:39.330 --> 01:04:40.705 align:middle line:84%
We'll talk in
subsequent lectures

01:04:40.705 --> 01:04:42.247 align:middle line:84%
about what silicidation
is all about.

01:04:42.247 --> 01:04:43.980 align:middle line:84%
I mostly want you to
get a feel for how

01:04:43.980 --> 01:04:48.000 align:middle line:84%
a two-dimensional simulation of
such a structure actually looks.

01:04:48.000 --> 01:04:50.590 align:middle line:90%


01:04:50.590 --> 01:04:54.700 align:middle line:84%
There's the final
structure here on slide 39,

01:04:54.700 --> 01:04:57.040 align:middle line:84%
showing the arsenic
concentration contours.

01:04:57.040 --> 01:05:00.820 align:middle line:84%
So here, this region in
between is your channel.

01:05:00.820 --> 01:05:03.130 align:middle line:84%
Here's the polysilicon
gate in green,

01:05:03.130 --> 01:05:04.870 align:middle line:90%
and this is your gate oxide.

01:05:04.870 --> 01:05:06.467 align:middle line:84%
And because of the
reoxidation, we

01:05:06.467 --> 01:05:08.050 align:middle line:84%
have a little bit
of the smile effect.

01:05:08.050 --> 01:05:10.030 align:middle line:84%
And see the way the device
seems to be smiling,

01:05:10.030 --> 01:05:11.290 align:middle line:90%
has a little smile here?

01:05:11.290 --> 01:05:13.930 align:middle line:84%
That's actually a
very happy device.

01:05:13.930 --> 01:05:15.790 align:middle line:84%
But it's not actually
all that good.

01:05:15.790 --> 01:05:17.060 align:middle line:90%
Smiling is not very good.

01:05:17.060 --> 01:05:19.870 align:middle line:84%
In fact, you want a gate
oxide that's perfectly flat,

01:05:19.870 --> 01:05:21.790 align:middle line:84%
has the same concentration--
same thickness

01:05:21.790 --> 01:05:23.680 align:middle line:84%
as much as possible
all the way across it.

01:05:23.680 --> 01:05:26.470 align:middle line:84%
It got unflat because
we did the re-ox,

01:05:26.470 --> 01:05:29.050 align:middle line:84%
and a little bit of oxidation
took place from the corners.

01:05:29.050 --> 01:05:33.040 align:middle line:84%
So these days, for the very
shallow, the very shortest

01:05:33.040 --> 01:05:35.830 align:middle line:84%
channel devices, reoxidation
is not such a popular thing

01:05:35.830 --> 01:05:41.650 align:middle line:84%
to do because it does create
this nonuniformity in the oxide

01:05:41.650 --> 01:05:43.750 align:middle line:90%
thickness.

01:05:43.750 --> 01:05:45.210 align:middle line:90%
In fact, you can go back.

01:05:45.210 --> 01:05:49.810 align:middle line:84%
What I did was I went back here
on page 40 and said, oh, OK,

01:05:49.810 --> 01:05:52.290 align:middle line:84%
is there some way we can
deal with this and maybe make

01:05:52.290 --> 01:05:58.290 align:middle line:84%
the re-ox have a little
bit less effect on the--

01:05:58.290 --> 01:06:02.400 align:middle line:84%
a little less of this extra
oxidation right at the corner?

01:06:02.400 --> 01:06:04.800 align:middle line:84%
So this is really what
we're talking about just

01:06:04.800 --> 01:06:06.802 align:middle line:84%
to give you a zoom
in on slide 40.

01:06:06.802 --> 01:06:08.760 align:middle line:84%
Here, actually, here's
a zoom in of what it is.

01:06:08.760 --> 01:06:13.020 align:middle line:84%
This nonuniform oxide thickness
took place under the gate.

01:06:13.020 --> 01:06:15.900 align:middle line:84%
And the real origin is
the lateral oxidation

01:06:15.900 --> 01:06:19.560 align:middle line:84%
under the poly during
the gate re-ox step.

01:06:19.560 --> 01:06:22.605 align:middle line:84%
This is when the gate re-ox
was done at 850 for 25 minutes.

01:06:22.605 --> 01:06:25.800 align:middle line:90%


01:06:25.800 --> 01:06:28.830 align:middle line:84%
So in fact, from the very
first lecture of class,

01:06:28.830 --> 01:06:31.337 align:middle line:84%
this is a real TDM
of a real device

01:06:31.337 --> 01:06:32.670 align:middle line:90%
to show you this effect is real.

01:06:32.670 --> 01:06:35.460 align:middle line:84%
See the way this
device is smiling also?

01:06:35.460 --> 01:06:37.470 align:middle line:84%
So SUPREM didn't
just make that up.

01:06:37.470 --> 01:06:42.300 align:middle line:84%
The oxidant did get under here
and oxidize in this region.

01:06:42.300 --> 01:06:46.658 align:middle line:84%
So the vt is going to be
nonuniform across this device.

01:06:46.658 --> 01:06:48.450 align:middle line:84%
So you have to actually
watch out for this.

01:06:48.450 --> 01:06:50.460 align:middle line:84%
This does really
happen, just to show you

01:06:50.460 --> 01:06:52.988 align:middle line:84%
that SUPREM is based in
reality with respect to some

01:06:52.988 --> 01:06:53.655 align:middle line:90%
of these things.

01:06:53.655 --> 01:06:58.030 align:middle line:90%


01:06:58.030 --> 01:07:05.680 align:middle line:84%
On slide 43, actually
did a little example

01:07:05.680 --> 01:07:11.150 align:middle line:84%
of how we can change the amount
of this effect that happens,

01:07:11.150 --> 01:07:13.130 align:middle line:84%
the amount of this
nonuniformity.

01:07:13.130 --> 01:07:15.130 align:middle line:84%
It may not be very clear
if I'm looking at this.

01:07:15.130 --> 01:07:17.680 align:middle line:84%
But on the left-hand
side, what was done was,

01:07:17.680 --> 01:07:26.830 align:middle line:84%
when we did the etch, we
etched all the way down, OK,

01:07:26.830 --> 01:07:29.170 align:middle line:90%
and then did a re-ox.

01:07:29.170 --> 01:07:33.630 align:middle line:84%
So on the left-hand side,
you're etching like this.

01:07:33.630 --> 01:07:38.150 align:middle line:84%
And here's your gate
oxide like this.

01:07:38.150 --> 01:07:41.180 align:middle line:84%
And we're basically
etching in the example

01:07:41.180 --> 01:07:47.150 align:middle line:84%
where we told SUPREM we act as
if we etched all the way down.

01:07:47.150 --> 01:07:49.430 align:middle line:84%
So the oxide-- the
prior to re-ox.

01:07:49.430 --> 01:07:52.010 align:middle line:90%


01:07:52.010 --> 01:07:54.950 align:middle line:84%
So when we put it in the furnace
on the left-hand side-- oh,

01:07:54.950 --> 01:07:55.550 align:middle line:90%
sorry--

01:07:55.550 --> 01:07:58.310 align:middle line:84%
when we put it in the
furnace for oxidation,

01:07:58.310 --> 01:08:01.160 align:middle line:84%
this oxide was gone
at that corner.

01:08:01.160 --> 01:08:04.110 align:middle line:90%


01:08:04.110 --> 01:08:06.360 align:middle line:84%
And that's what you end up
with on the left-hand side.

01:08:06.360 --> 01:08:08.440 align:middle line:84%
So you can imagine,
when that oxide is gone,

01:08:08.440 --> 01:08:11.050 align:middle line:84%
then you can get a
fair amount of attack

01:08:11.050 --> 01:08:17.939 align:middle line:84%
in here laterally of the oxidant
getting underneath there.

01:08:17.939 --> 01:08:23.130 align:middle line:84%
So what was done here on
the right-hand side instead,

01:08:23.130 --> 01:08:25.649 align:middle line:84%
50 of the 70
angstroms were etched.

01:08:25.649 --> 01:08:28.410 align:middle line:84%
So we left a lot of
the oxide on there

01:08:28.410 --> 01:08:32.175 align:middle line:90%
and then just oxidized it--

01:08:32.175 --> 01:08:35.340 align:middle line:84%
re-ox was done at a lower
temperature, 825 for a shorter

01:08:35.340 --> 01:08:37.720 align:middle line:90%
time, 12 minutes.

01:08:37.720 --> 01:08:39.810 align:middle line:84%
So you get some of the
benefits of the re-ox

01:08:39.810 --> 01:08:41.189 align:middle line:90%
without some of that extra.

01:08:41.189 --> 01:08:45.390 align:middle line:84%
So in this example,
when we did the etching,

01:08:45.390 --> 01:08:47.760 align:middle line:90%
it didn't remove it all.

01:08:47.760 --> 01:08:52.840 align:middle line:84%
It looked like this when it
went into the oxidation furnace.

01:08:52.840 --> 01:08:54.930 align:middle line:84%
It looked like that
and then got oxidized.

01:08:54.930 --> 01:08:57.420 align:middle line:84%
So, by refining
the etch process,

01:08:57.420 --> 01:08:59.861 align:middle line:90%
we didn't etch all the way down.

01:08:59.861 --> 01:09:02.069 align:middle line:84%
And if you look carefully,
I think on the next slide,

01:09:02.069 --> 01:09:05.430 align:middle line:84%
it'll be maybe a
little more obvious.

01:09:05.430 --> 01:09:09.420 align:middle line:84%
The lateral nonuniformity
is quite a bit reduced.

01:09:09.420 --> 01:09:13.020 align:middle line:84%
This oxide thickness is much
more uniform going across here.

01:09:13.020 --> 01:09:17.580 align:middle line:84%
There's still a little bit of
it, but 825 for 12 minutes,

01:09:17.580 --> 01:09:19.770 align:middle line:84%
there's a lot less of that
lateral nonuniformity.

01:09:19.770 --> 01:09:22.000 align:middle line:84%
So it's an example
of a process--

01:09:22.000 --> 01:09:26.290 align:middle line:84%
you can use SUPREM-IV to
optimize reasonably efficiently

01:09:26.290 --> 01:09:30.175 align:middle line:84%
and reasonably accurately in
this two-dimensional model.

01:09:30.175 --> 01:09:33.130 align:middle line:90%


01:09:33.130 --> 01:09:35.560 align:middle line:84%
OK, so let me go
on to summarize.

01:09:35.560 --> 01:09:39.350 align:middle line:84%
The simulators, like
SUPREM-IV, which, by the way,

01:09:39.350 --> 01:09:42.520 align:middle line:84%
I didn't tell you, but
SUPREM-IV was originally

01:09:42.520 --> 01:09:45.410 align:middle line:90%
written at Stanford.

01:09:45.410 --> 01:09:47.689 align:middle line:84%
And sometimes that's
called SSuprem

01:09:47.689 --> 01:09:50.120 align:middle line:84%
That's where it came out
of originally in the 1980s.

01:09:50.120 --> 01:09:53.990 align:middle line:84%
It was then commercialized in
a small company called TMA.

01:09:53.990 --> 01:09:57.290 align:middle line:84%
That company was bought out by
another company called Avant.

01:09:57.290 --> 01:10:01.940 align:middle line:84%
And Avant later
sold the technology

01:10:01.940 --> 01:10:04.190 align:middle line:90%
to a company called Synopsis.

01:10:04.190 --> 01:10:05.750 align:middle line:90%
Synopsis is a big design house.

01:10:05.750 --> 01:10:09.500 align:middle line:84%
They make a lot of CAD
software for designing chips.

01:10:09.500 --> 01:10:11.660 align:middle line:84%
But they also
support TSUPREM-IV.

01:10:11.660 --> 01:10:15.080 align:middle line:84%
So if you want to have
questions about the simulator,

01:10:15.080 --> 01:10:18.290 align:middle line:84%
you need to contact people at
this company called Synopsis.

01:10:18.290 --> 01:10:21.740 align:middle line:84%
There are other
simulators out there.

01:10:21.740 --> 01:10:23.840 align:middle line:84%
SUPREM-IV is one of
the most popular,

01:10:23.840 --> 01:10:25.490 align:middle line:84%
but there's another
company called

01:10:25.490 --> 01:10:29.840 align:middle line:84%
Silvaco, which makes a competing
product, which is called ATHENA.

01:10:29.840 --> 01:10:32.618 align:middle line:84%
In any case, these
simulators like this,

01:10:32.618 --> 01:10:34.160 align:middle line:84%
they've been developed
over the years

01:10:34.160 --> 01:10:36.290 align:middle line:84%
to enable what we
call physically

01:10:36.290 --> 01:10:38.720 align:middle line:84%
accurate or robust or
correct simulations

01:10:38.720 --> 01:10:40.027 align:middle line:90%
of complex processes.

01:10:40.027 --> 01:10:42.110 align:middle line:84%
However, I've tried to
tell you to take everything

01:10:42.110 --> 01:10:44.277 align:middle line:84%
with a grain of salt.
Don't believe it

01:10:44.277 --> 01:10:46.860 align:middle line:84%
just because you simulate it in
SUPREM and it looks like that.

01:10:46.860 --> 01:10:48.960 align:middle line:84%
One thing, you might
have done it wrong.

01:10:48.960 --> 01:10:52.950 align:middle line:84%
You might have used
the wrong grid factor.

01:10:52.950 --> 01:10:54.840 align:middle line:84%
SUPREM itself has
parameters in it

01:10:54.840 --> 01:10:57.842 align:middle line:84%
that are unknown, that
somebody just stuck in there.

01:10:57.842 --> 01:10:59.550 align:middle line:84%
Some graduate student
writing the program

01:10:59.550 --> 01:11:01.320 align:middle line:84%
said, oh, I don't know exactly
what this parameter is.

01:11:01.320 --> 01:11:02.320 align:middle line:90%
I'll put this number in.

01:11:02.320 --> 01:11:03.100 align:middle line:90%
It's rough.

01:11:03.100 --> 01:11:05.350 align:middle line:84%
Well, you need to find out
what parameter is in there.

01:11:05.350 --> 01:11:07.607 align:middle line:84%
And if you go to the
appendix in the manual,

01:11:07.607 --> 01:11:09.690 align:middle line:84%
it'll tell you in general
what all the numbers are

01:11:09.690 --> 01:11:10.400 align:middle line:90%
that it's using.

01:11:10.400 --> 01:11:12.150 align:middle line:84%
And you can decide
whether those numbers--

01:11:12.150 --> 01:11:15.150 align:middle line:90%
whether you like them or not.

01:11:15.150 --> 01:11:17.610 align:middle line:84%
The nice thing about these
simulations from SUPREM-IV

01:11:17.610 --> 01:11:20.580 align:middle line:84%
or ATHENA, you can feed them
into a device simulator,

01:11:20.580 --> 01:11:22.440 align:middle line:84%
such as Medici or
whatever, and then

01:11:22.440 --> 01:11:24.600 align:middle line:84%
predict IV and CV
characteristics,

01:11:24.600 --> 01:11:26.770 align:middle line:84%
the actual electrical
characteristics of the device.

01:11:26.770 --> 01:11:28.590 align:middle line:84%
So they are designed
to be coupled,

01:11:28.590 --> 01:11:33.060 align:middle line:84%
the process simulator
and the device simulator.

01:11:33.060 --> 01:11:36.513 align:middle line:90%
And that's a very nice feature.

01:11:36.513 --> 01:11:37.930 align:middle line:84%
There's a lot of
new understanding

01:11:37.930 --> 01:11:41.860 align:middle line:84%
that's being developed and
issues related to TED and OED

01:11:41.860 --> 01:11:45.365 align:middle line:84%
and other anomalous effects,
low energy ion implants.

01:11:45.365 --> 01:11:46.990 align:middle line:84%
I showed you some
low-energy phosphorus

01:11:46.990 --> 01:11:51.100 align:middle line:84%
where SUPREM doesn't do a very
good job of modeling the data.

01:11:51.100 --> 01:11:53.860 align:middle line:84%
Highly tilted implants
with shadowing,

01:11:53.860 --> 01:11:55.240 align:middle line:90%
oxidation of trenches.

01:11:55.240 --> 01:11:58.810 align:middle line:84%
SUPREM can handle most
of these situations

01:11:58.810 --> 01:12:00.310 align:middle line:84%
because it has the
physics built in.

01:12:00.310 --> 01:12:03.055 align:middle line:84%
Exactly the accuracy, that's
always the question mark.

01:12:03.055 --> 01:12:05.680 align:middle line:90%


01:12:05.680 --> 01:12:07.660 align:middle line:84%
Whenever you're running
these simulators,

01:12:07.660 --> 01:12:10.400 align:middle line:84%
keep in mind the
basic physical models.

01:12:10.400 --> 01:12:14.087 align:middle line:84%
There are a lot of parameters
that must be known accurately,

01:12:14.087 --> 01:12:15.670 align:middle line:84%
and we don't know
them all accurately.

01:12:15.670 --> 01:12:18.330 align:middle line:90%
So keep your eyes open.

01:12:18.330 --> 01:12:23.760 align:middle line:84%
A big caveat is keep the
mesh or the grid in mind.

01:12:23.760 --> 01:12:25.590 align:middle line:84%
When your grid is
fine enough, you

01:12:25.590 --> 01:12:28.920 align:middle line:84%
should be able to get the exact
same solution with minor changes

01:12:28.920 --> 01:12:29.620 align:middle line:90%
to the grid.

01:12:29.620 --> 01:12:31.260 align:middle line:90%
So I run it for a certain grid.

01:12:31.260 --> 01:12:33.060 align:middle line:90%
I cut the grid spacing in half.

01:12:33.060 --> 01:12:34.810 align:middle line:84%
The solution should
look identical.

01:12:34.810 --> 01:12:37.050 align:middle line:84%
If all of a sudden the
solution looks much smoother

01:12:37.050 --> 01:12:40.140 align:middle line:84%
when I cut the grid in half,
the spacing or much finer,

01:12:40.140 --> 01:12:41.820 align:middle line:84%
then obviously the
original solution

01:12:41.820 --> 01:12:43.650 align:middle line:90%
didn't have a fine enough grid.

01:12:43.650 --> 01:12:45.420 align:middle line:84%
So you've got to do
these sanity checks.

01:12:45.420 --> 01:12:47.820 align:middle line:90%
Run it once with a certain grid.

01:12:47.820 --> 01:12:49.260 align:middle line:90%
Then use twice the grid points.

01:12:49.260 --> 01:12:50.610 align:middle line:90%
Does it look a lot smoother?

01:12:50.610 --> 01:12:52.500 align:middle line:84%
Well, that means you probably
didn't do a good enough job

01:12:52.500 --> 01:12:53.280 align:middle line:90%
the first time.

01:12:53.280 --> 01:12:54.180 align:middle line:90%
And then do it again.

01:12:54.180 --> 01:12:55.650 align:middle line:90%
And eventually, it'll converge.

01:12:55.650 --> 01:12:59.220 align:middle line:84%
It has about the same smoothness
regardless of your grid.

01:12:59.220 --> 01:13:01.470 align:middle line:84%
In which case, your grid
is probably fine enough.

01:13:01.470 --> 01:13:03.930 align:middle line:84%
Your solution should be
independent of the grid.

01:13:03.930 --> 01:13:10.018 align:middle line:84%
Otherwise, that's not
physically realistic.

01:13:10.018 --> 01:13:12.310 align:middle line:84%
There's a lot of different
process integration schemes.

01:13:12.310 --> 01:13:15.160 align:middle line:84%
I just showed you one,
just changing the order

01:13:15.160 --> 01:13:17.230 align:middle line:90%
of the device, of the anneals.

01:13:17.230 --> 01:13:19.480 align:middle line:84%
The simulators help us to
understand these interaction

01:13:19.480 --> 01:13:21.310 align:middle line:84%
between the various
steps and how

01:13:21.310 --> 01:13:24.220 align:middle line:84%
to optimize the overall
technology in ways

01:13:24.220 --> 01:13:26.540 align:middle line:84%
that you could never do if
you just did this by hand.

01:13:26.540 --> 01:13:28.630 align:middle line:90%
So you've used SUPREM-IV now.

01:13:28.630 --> 01:13:30.760 align:middle line:84%
You're going to use it
again in homework number 5.

01:13:30.760 --> 01:13:35.110 align:middle line:84%
So I think gives you some idea
of how powerful this tool is.

01:13:35.110 --> 01:13:37.550 align:middle line:84%
But if you are going to really
use it in your research,

01:13:37.550 --> 01:13:38.860 align:middle line:90%
make sure you read the manual.

01:13:38.860 --> 01:13:40.360 align:middle line:84%
It is very important
because there's

01:13:40.360 --> 01:13:43.420 align:middle line:84%
a lot of little things in
there you need to know about.

01:13:43.420 --> 01:13:45.370 align:middle line:90%
OK, that's it for today.

01:13:45.370 --> 01:13:47.770 align:middle line:84%
Homework number 4,
please bring up front.

01:13:47.770 --> 01:13:50.890 align:middle line:84%
Homework number 3 is in the
orange folder in the back

01:13:50.890 --> 01:13:52.180 align:middle line:90%
by the TA.

01:13:52.180 --> 01:13:55.600 align:middle line:90%
And I guess that's it.

01:13:55.600 --> 01:14:01.017 align:middle line:84%
We'll meet on-- oh,
somebody have the sign

01:14:01.017 --> 01:14:02.350 align:middle line:90%
up sheet for your final project?

01:14:02.350 --> 01:14:03.760 align:middle line:90%
Oh, great.

01:14:03.760 --> 01:14:04.630 align:middle line:90%
Thanks.

01:14:04.630 --> 01:14:06.900 align:middle line:90%
Make sure you sign up.

01:14:06.900 --> 01:14:08.000 align:middle line:90%