00:00:00.000 --> 00:00:03.420 align:middle line:90%
JUDY HOYT: This is--

00:00:03.420 --> 00:00:07.380 align:middle line:84%
today's lecture is going to be
the final lecture on chapter 7.

00:00:07.380 --> 00:00:09.660 align:middle line:84%
It's not the final
lecture on diffusion.

00:00:09.660 --> 00:00:13.050 align:middle line:84%
We're going to continue talking
about diffusion in chapter 8,

00:00:13.050 --> 00:00:15.550 align:middle line:84%
once we've talked
about ion implantation.

00:00:15.550 --> 00:00:18.480 align:middle line:84%
But this will
finish up chapter 7.

00:00:18.480 --> 00:00:20.730 align:middle line:84%
So hopefully you're finishing
reading that chapter

00:00:20.730 --> 00:00:22.740 align:middle line:90%
at this point.

00:00:22.740 --> 00:00:25.470 align:middle line:84%
Diffusion is probably
the biggest topic

00:00:25.470 --> 00:00:29.130 align:middle line:84%
we cover in this course in
terms of the overall complexity

00:00:29.130 --> 00:00:31.697 align:middle line:90%
and the depth of the modeling.

00:00:31.697 --> 00:00:33.780 align:middle line:84%
So there's a lot of points
I want to cover or just

00:00:33.780 --> 00:00:34.988 align:middle line:90%
try to review from last time.

00:00:34.988 --> 00:00:37.680 align:middle line:84%
The last lecture
was pretty dense.

00:00:37.680 --> 00:00:40.340 align:middle line:84%
There was a lot of
material to cover.

00:00:40.340 --> 00:00:43.480 align:middle line:84%
So what we talked
about last time

00:00:43.480 --> 00:00:48.400 align:middle line:84%
was that there are these
so-called Fermi-level effects,

00:00:48.400 --> 00:00:51.880 align:middle line:84%
or high-concentration effects,
and electric field effects,

00:00:51.880 --> 00:00:54.040 align:middle line:84%
and that both of
those become important

00:00:54.040 --> 00:00:56.705 align:middle line:84%
when the carrier
concentration-- either N over P,

00:00:56.705 --> 00:00:58.330 align:middle line:84%
depending on how the
material's doped--

00:00:58.330 --> 00:01:00.640 align:middle line:84%
when either of those
carrier concentrations

00:01:00.640 --> 00:01:04.930 align:middle line:84%
is greater than NI, N sub I,
at the diffusion temperature,

00:01:04.930 --> 00:01:08.710 align:middle line:84%
then these high concentration
effects become important.

00:01:08.710 --> 00:01:11.830 align:middle line:84%
The basic idea of the
model that we have

00:01:11.830 --> 00:01:16.210 align:middle line:84%
is that the Fermi level, as it
moves up and down in the bandgap

00:01:16.210 --> 00:01:19.330 align:middle line:84%
in response to the doping level,
depending on how you have it

00:01:19.330 --> 00:01:22.570 align:middle line:84%
doped, as you're
doped more heavily,

00:01:22.570 --> 00:01:26.290 align:middle line:84%
it tends to increase the
point defect concentration

00:01:26.290 --> 00:01:27.995 align:middle line:90%
as the doping increases.

00:01:27.995 --> 00:01:30.370 align:middle line:84%
We know we've seen that in
one of your homework problems.

00:01:30.370 --> 00:01:31.660 align:middle line:90%
You had to calculate that.

00:01:31.660 --> 00:01:34.270 align:middle line:84%
And the increase in point
defect concentration

00:01:34.270 --> 00:01:37.060 align:middle line:84%
then increases the
diffusivity of a dopant.

00:01:37.060 --> 00:01:41.810 align:middle line:84%
And this leads to, or can lead
to, generally more box-like

00:01:41.810 --> 00:01:45.650 align:middle line:84%
shape profiles because as the
dopant diffuses, as you get out

00:01:45.650 --> 00:01:49.460 align:middle line:84%
to the edge of that profile,
the concentration is dropping.

00:01:49.460 --> 00:01:51.710 align:middle line:84%
And as the concentration
of the doping is dropping,

00:01:51.710 --> 00:01:53.240 align:middle line:90%
the Fermi level is moving.

00:01:53.240 --> 00:01:55.890 align:middle line:84%
The total point defect
concentration is going down.

00:01:55.890 --> 00:01:58.790 align:middle line:84%
So you tend to get these
very steep fall-offs

00:01:58.790 --> 00:02:01.850 align:middle line:90%
in your profiles.

00:02:01.850 --> 00:02:03.790 align:middle line:84%
So in addition to
this, this leads

00:02:03.790 --> 00:02:07.420 align:middle line:84%
to this concentration-dependent
diffusion.

00:02:07.420 --> 00:02:10.970 align:middle line:84%
We talked about effects like
oxidation-enhanced diffusion,

00:02:10.970 --> 00:02:13.780 align:middle line:84%
which is abbreviated OED,
oxidation retarded diffusion,

00:02:13.780 --> 00:02:18.070 align:middle line:84%
ORD, and the growth or
shrinkage of stacking faults.

00:02:18.070 --> 00:02:22.420 align:middle line:84%
And these phenomenon
can be explained by

00:02:22.420 --> 00:02:25.000 align:middle line:84%
not by looking at Fick's
law per se or whatever,

00:02:25.000 --> 00:02:28.630 align:middle line:84%
but by looking at atomic
scale diffusion models.

00:02:28.630 --> 00:02:31.160 align:middle line:90%


00:02:31.160 --> 00:02:34.730 align:middle line:84%
And in fact, what we
talked about last time is

00:02:34.730 --> 00:02:42.280 align:middle line:84%
that based on the impact on
stacking faults, that oxidation,

00:02:42.280 --> 00:02:45.100 align:middle line:84%
people believe, injects
excess silicon interstitials

00:02:45.100 --> 00:02:49.810 align:middle line:84%
into the bulk, while thermal
nitridation, which, again, you

00:02:49.810 --> 00:02:51.490 align:middle line:84%
may not be as familiar
with nitridation,

00:02:51.490 --> 00:02:54.730 align:middle line:84%
is basically the
reaction of the silicon

00:02:54.730 --> 00:02:58.780 align:middle line:84%
surface with a gas-like ammonia
to create silicon nitride.

00:02:58.780 --> 00:03:03.880 align:middle line:84%
That process is believed to
inject vacancies into the bulk.

00:03:03.880 --> 00:03:06.460 align:middle line:84%
And based on monitoring
these processes,

00:03:06.460 --> 00:03:09.670 align:middle line:84%
people believe that boron and
phosphorus diffuse primarily

00:03:09.670 --> 00:03:10.510 align:middle line:90%
with interstitials.

00:03:10.510 --> 00:03:14.740 align:middle line:84%
So they have an F sub I number
in the fraction interstitial

00:03:14.740 --> 00:03:16.750 align:middle line:90%
contribution to diffusion of 1.

00:03:16.750 --> 00:03:20.300 align:middle line:84%
And antimony diffuses
primarily with vacancies.

00:03:20.300 --> 00:03:25.690 align:middle line:84%
So F sub I is pretty
close to zero, maybe 0.02.

00:03:25.690 --> 00:03:28.360 align:middle line:84%
So today I wanted to review
these atomic scale mechanisms

00:03:28.360 --> 00:03:30.350 align:middle line:84%
because we kind of
breezed through them

00:03:30.350 --> 00:03:32.390 align:middle line:84%
at the end of the last
lecture pretty fast.

00:03:32.390 --> 00:03:36.050 align:middle line:84%
And then I want to go
on to some new material

00:03:36.050 --> 00:03:39.980 align:middle line:84%
and just give you a brief
example, or a brief look at one

00:03:39.980 --> 00:03:43.880 align:middle line:84%
example, of how the
point defect gradient--

00:03:43.880 --> 00:03:46.220 align:middle line:84%
we talked about this last
time-- that not only does

00:03:46.220 --> 00:03:49.910 align:middle line:84%
the dopant gradient,
D arsenic by DX,

00:03:49.910 --> 00:03:52.200 align:middle line:84%
but the point defect
gradient, for instance,

00:03:52.200 --> 00:03:53.870 align:middle line:84%
the interstitial
gradient, can actually

00:03:53.870 --> 00:03:56.450 align:middle line:84%
drive diffusion in
a way that actually

00:03:56.450 --> 00:03:57.930 align:middle line:90%
looks like uphill diffusion.

00:03:57.930 --> 00:04:01.160 align:middle line:84%
So it's kind of a
nonFickian phenomenon.

00:04:01.160 --> 00:04:05.720 align:middle line:84%
And this leads to a
phenomenon in MOSFETs

00:04:05.720 --> 00:04:08.163 align:middle line:84%
that's called the-- in
CMOS [INAUDIBLE] what's

00:04:08.163 --> 00:04:09.830 align:middle line:84%
called the reverse
short-channel effect.

00:04:09.830 --> 00:04:11.090 align:middle line:90%
And I'll just introduce that.

00:04:11.090 --> 00:04:13.700 align:middle line:84%
We'll talk about it
in subsequent lectures

00:04:13.700 --> 00:04:15.373 align:middle line:90%
in more detail.

00:04:15.373 --> 00:04:17.290 align:middle line:84%
And then the second half
of the lecture, we're

00:04:17.290 --> 00:04:19.415 align:middle line:84%
going to talk about profile
measurement techniques.

00:04:19.415 --> 00:04:22.029 align:middle line:84%
How do we measure all
these complex profiles?

00:04:22.029 --> 00:04:24.560 align:middle line:90%
What's the best way to do it?

00:04:24.560 --> 00:04:27.370 align:middle line:84%
OK, so let's review a little bit
on this atomic scale mechanism.

00:04:27.370 --> 00:04:29.120 align:middle line:84%
And what I would
encourage you in thinking

00:04:29.120 --> 00:04:30.710 align:middle line:84%
about the atomic
scale mechanisms,

00:04:30.710 --> 00:04:36.440 align:middle line:84%
rather than just looking at this
particular, very static lattice

00:04:36.440 --> 00:04:39.532 align:middle line:84%
and imagining how
atoms might move,

00:04:39.532 --> 00:04:41.240 align:middle line:84%
maybe you sit down
with a piece of paper,

00:04:41.240 --> 00:04:44.660 align:middle line:84%
start out and draw yourself a
simple two-dimensional lattice.

00:04:44.660 --> 00:04:47.310 align:middle line:84%
Draw silicon atoms
everywhere except one point,

00:04:47.310 --> 00:04:48.620 align:middle line:90%
which you call your vacancy.

00:04:48.620 --> 00:04:52.200 align:middle line:84%
Draw a blue atom, or a
pink or red or whatever,

00:04:52.200 --> 00:04:54.492 align:middle line:84%
which you call your
arsenic doping,

00:04:54.492 --> 00:04:55.700 align:middle line:90%
or whatever it happens to be.

00:04:55.700 --> 00:04:57.890 align:middle line:84%
And draw a couple of
time steps for yourself.

00:04:57.890 --> 00:04:59.660 align:middle line:84%
And see if you
can figure out how

00:04:59.660 --> 00:05:03.110 align:middle line:84%
this arsenic atom, this dopant
atom, A, and the vacancy

00:05:03.110 --> 00:05:06.590 align:middle line:84%
together, by staying in close
proximity to each other,

00:05:06.590 --> 00:05:08.528 align:middle line:90%
can move throughout the lattice.

00:05:08.528 --> 00:05:10.070 align:middle line:84%
Give yourself a
couple of time shots.

00:05:10.070 --> 00:05:12.110 align:middle line:84%
And I think that
will help understand

00:05:12.110 --> 00:05:16.220 align:middle line:90%
how these things move together.

00:05:16.220 --> 00:05:20.150 align:middle line:84%
So in this vacancy-assisted
model or mechanism,

00:05:20.150 --> 00:05:23.360 align:middle line:84%
what we do is we say A, where
is A dopant-- it could be boron,

00:05:23.360 --> 00:05:25.580 align:middle line:84%
phosphorus, arsenic,
antimony-- we

00:05:25.580 --> 00:05:29.810 align:middle line:84%
combine that with a vacancy,
which is pictured here,

00:05:29.810 --> 00:05:31.160 align:middle line:90%
an absence of a silicon atom.

00:05:31.160 --> 00:05:33.538 align:middle line:90%
And it forms a pair, AV.

00:05:33.538 --> 00:05:35.330 align:middle line:84%
OK, so you say, well,
that's fairly simple.

00:05:35.330 --> 00:05:37.700 align:middle line:90%
What's unique about this?

00:05:37.700 --> 00:05:40.640 align:middle line:84%
Well, here A is a
substitutional dopant atom.

00:05:40.640 --> 00:05:44.160 align:middle line:90%
This pair AV is mobile.

00:05:44.160 --> 00:05:46.990 align:middle line:84%
The substitutional dopant
atom A is immobile.

00:05:46.990 --> 00:05:50.270 align:middle line:84%
So what we're saying is that
dopants in silicon do not move.

00:05:50.270 --> 00:05:51.230 align:middle line:90%
They do not diffuse.

00:05:51.230 --> 00:05:53.170 align:middle line:84%
This is the
assumption, unless they

00:05:53.170 --> 00:05:56.080 align:middle line:84%
are paired with either a
vacancy or interstitial.

00:05:56.080 --> 00:05:57.550 align:middle line:84%
But if they're
just in the lattice

00:05:57.550 --> 00:06:00.050 align:middle line:84%
and there were no vacancies
around, no interstitials around,

00:06:00.050 --> 00:06:01.210 align:middle line:90%
the dopant won't diffuse.

00:06:01.210 --> 00:06:03.830 align:middle line:84%
So this is a hypothesis
that we're making.

00:06:03.830 --> 00:06:08.380 align:middle line:84%
And we use it to basically
model all the diffusion

00:06:08.380 --> 00:06:09.790 align:middle line:90%
of dopants in silicon.

00:06:09.790 --> 00:06:12.370 align:middle line:84%
So here's the example of
being paired with a vacancy.

00:06:12.370 --> 00:06:15.790 align:middle line:84%
Obviously the dopant here could
hop into this vacant site.

00:06:15.790 --> 00:06:18.340 align:middle line:84%
The vacancy can move up
here where the dopant was.

00:06:18.340 --> 00:06:19.340 align:middle line:90%
Now what happens?

00:06:19.340 --> 00:06:21.370 align:middle line:84%
Well, the dopant can
stay put for a moment.

00:06:21.370 --> 00:06:23.890 align:middle line:84%
The vacancy can move over
here to this lattice site.

00:06:23.890 --> 00:06:26.200 align:middle line:84%
And a silicon atom
can move there.

00:06:26.200 --> 00:06:27.640 align:middle line:90%
The vacancy can continue.

00:06:27.640 --> 00:06:28.680 align:middle line:90%
It can move right here.

00:06:28.680 --> 00:06:30.430 align:middle line:84%
And this silicon atom
would move up there.

00:06:30.430 --> 00:06:32.050 align:middle line:84%
Now I have the
vacancy at this spot

00:06:32.050 --> 00:06:34.960 align:middle line:84%
down here at the bottom and
the dopant atom next to it.

00:06:34.960 --> 00:06:36.790 align:middle line:84%
Well, now they can
exchange places.

00:06:36.790 --> 00:06:38.510 align:middle line:84%
And the dopant atom
has moved here.

00:06:38.510 --> 00:06:40.780 align:middle line:84%
So it moved from that
point to that point.

00:06:40.780 --> 00:06:44.420 align:middle line:84%
And how it got there was just by
a couple of steps of the vacancy

00:06:44.420 --> 00:06:47.528 align:middle line:84%
hanging around nearby
as a pair, essentially.

00:06:47.528 --> 00:06:49.070 align:middle line:84%
And that's how the
dopant atom moved.

00:06:49.070 --> 00:06:51.230 align:middle line:84%
Without that vacancy,
it couldn't have.

00:06:51.230 --> 00:06:53.900 align:middle line:84%
Similarly, there
are interstitial or

00:06:53.900 --> 00:06:56.990 align:middle line:84%
interstitial-assisted
mechanisms.

00:06:56.990 --> 00:06:59.630 align:middle line:84%
And we write this as
a chemical equation.

00:06:59.630 --> 00:07:04.070 align:middle line:84%
Substitutional atom A, dopant
plus silicon interstitial

00:07:04.070 --> 00:07:06.230 align:middle line:90%
forms an AI pair.

00:07:06.230 --> 00:07:09.870 align:middle line:84%
And it's only this AI
pair that can move.

00:07:09.870 --> 00:07:10.980 align:middle line:90%
And this is an example.

00:07:10.980 --> 00:07:12.480 align:middle line:84%
There are a couple
of examples here.

00:07:12.480 --> 00:07:13.980 align:middle line:84%
One is called the
kick-out mechanism

00:07:13.980 --> 00:07:16.040 align:middle line:84%
where you have a pure
interstitial, a silicon

00:07:16.040 --> 00:07:18.350 align:middle line:84%
atom that's actually in
the interstitial spaces.

00:07:18.350 --> 00:07:20.300 align:middle line:84%
It's an extra atom
in the lattice.

00:07:20.300 --> 00:07:24.920 align:middle line:84%
And it can come along and it
can kick out that dopant atom.

00:07:24.920 --> 00:07:26.870 align:middle line:90%
And then they exist as a pair.

00:07:26.870 --> 00:07:28.950 align:middle line:84%
And then the dopant can
kick out a silicon atom.

00:07:28.950 --> 00:07:30.580 align:middle line:84%
And so they kind
of move along, you

00:07:30.580 --> 00:07:33.350 align:middle line:84%
can imagine this pair,
always one of them--

00:07:33.350 --> 00:07:37.190 align:middle line:84%
either the dopant or the
silicon atom-- being off-site,

00:07:37.190 --> 00:07:38.540 align:middle line:90%
so to speak.

00:07:38.540 --> 00:07:39.840 align:middle line:90%
That's one mechanism.

00:07:39.840 --> 00:07:42.145 align:middle line:84%
The other is an
interstitial C mechanism.

00:07:42.145 --> 00:07:44.270 align:middle line:84%
It's a little bit-- the
distinction is a little bit

00:07:44.270 --> 00:07:44.780 align:middle line:90%
different.

00:07:44.780 --> 00:07:47.180 align:middle line:84%
The interstitial mechanism
is this atom that's

00:07:47.180 --> 00:07:49.070 align:middle line:84%
here in the
interstitial space is

00:07:49.070 --> 00:07:51.980 align:middle line:84%
presumed to be not bonded, not
covalently bonded in any way.

00:07:51.980 --> 00:07:54.410 align:middle line:84%
In the interstitial
C mechanism, the idea

00:07:54.410 --> 00:07:57.050 align:middle line:84%
is that a dopant
and a silicon atom

00:07:57.050 --> 00:07:59.930 align:middle line:84%
are kind of both bonded and
both sharing partial bonds.

00:07:59.930 --> 00:08:02.730 align:middle line:84%
They're sharing a substitutional
site, if you want.

00:08:02.730 --> 00:08:04.730 align:middle line:84%
There's an extra atom
there because there's only

00:08:04.730 --> 00:08:06.897 align:middle line:84%
supposed to be one atom at
that site in the lattice.

00:08:06.897 --> 00:08:07.820 align:middle line:90%
There's two of them.

00:08:07.820 --> 00:08:09.110 align:middle line:84%
One of them happens
to be silicon.

00:08:09.110 --> 00:08:10.235 align:middle line:90%
One happens to be a dopant.

00:08:10.235 --> 00:08:12.470 align:middle line:90%
And they can go along sharing.

00:08:12.470 --> 00:08:14.210 align:middle line:84%
This can share, and
then the dopant atom

00:08:14.210 --> 00:08:17.480 align:middle line:84%
can then share with its neighbor
and could diffuse perhaps

00:08:17.480 --> 00:08:18.750 align:middle line:90%
along bond directions.

00:08:18.750 --> 00:08:21.530 align:middle line:84%
So this is an interstitial
or interstitial C assisted

00:08:21.530 --> 00:08:22.100 align:middle line:90%
mechanism.

00:08:22.100 --> 00:08:24.770 align:middle line:84%
Again, unless it's paired
with one of the point defects,

00:08:24.770 --> 00:08:28.790 align:middle line:84%
we assume that a substitutional
dopant atom otherwise cannot

00:08:28.790 --> 00:08:31.280 align:middle line:90%
move.

00:08:31.280 --> 00:08:31.780 align:middle line:90%
OK.

00:08:31.780 --> 00:08:34.809 align:middle line:84%
So last time we also
talked about this picture.

00:08:34.809 --> 00:08:37.330 align:middle line:84%
I've shown it several times
now, but hopefully you

00:08:37.330 --> 00:08:39.640 align:middle line:84%
start to become
comfortable with it.

00:08:39.640 --> 00:08:42.159 align:middle line:84%
What this exemplifies
is that how

00:08:42.159 --> 00:08:45.550 align:middle line:84%
we use a process going on
at the surface in this field

00:08:45.550 --> 00:08:47.680 align:middle line:84%
to probe the atomic
scale mechanisms.

00:08:47.680 --> 00:08:50.170 align:middle line:84%
The problem is nobody can
really see interstitials.

00:08:50.170 --> 00:08:51.320 align:middle line:90%
They diffuse too fast.

00:08:51.320 --> 00:08:53.920 align:middle line:84%
There's no real way of looking
at them with a microscope

00:08:53.920 --> 00:08:54.880 align:middle line:90%
or something like that.

00:08:54.880 --> 00:08:55.880 align:middle line:90%
That's a problem.

00:08:55.880 --> 00:09:00.250 align:middle line:84%
So what we do more often
is subject the surface

00:09:00.250 --> 00:09:03.010 align:middle line:84%
to some kind of a process
that we feel either injects

00:09:03.010 --> 00:09:04.810 align:middle line:84%
interstitials or
injects vacancies.

00:09:04.810 --> 00:09:07.060 align:middle line:84%
And then we see what
happens somewhere

00:09:07.060 --> 00:09:11.327 align:middle line:84%
at a distance in the crystal
to infer, or to probe,

00:09:11.327 --> 00:09:12.410 align:middle line:90%
what we think is going on.

00:09:12.410 --> 00:09:13.970 align:middle line:90%
Admittedly, it's indirect.

00:09:13.970 --> 00:09:16.670 align:middle line:84%
But if you build
up enough evidence,

00:09:16.670 --> 00:09:18.560 align:middle line:84%
people believe they can
make a case that this

00:09:18.560 --> 00:09:20.430 align:middle line:90%
is what's probably going on.

00:09:20.430 --> 00:09:22.460 align:middle line:84%
So there are two
service processes

00:09:22.460 --> 00:09:24.110 align:middle line:90%
that are very commonly used.

00:09:24.110 --> 00:09:26.330 align:middle line:90%
First one is oxidation.

00:09:26.330 --> 00:09:27.860 align:middle line:90%
And it's usually done locally.

00:09:27.860 --> 00:09:29.930 align:middle line:84%
In order to do an
OED experiment,

00:09:29.930 --> 00:09:32.330 align:middle line:84%
you typically don't put
one wafer in a furnace

00:09:32.330 --> 00:09:34.850 align:middle line:84%
and oxidize it and put a
second wafer in a furnace

00:09:34.850 --> 00:09:38.060 align:middle line:84%
and have it under inert because
first of all, the furnace

00:09:38.060 --> 00:09:40.610 align:middle line:84%
may not be the exact same
temperature every run.

00:09:40.610 --> 00:09:41.967 align:middle line:90%
We know they're not perfect.

00:09:41.967 --> 00:09:43.550 align:middle line:84%
Temperature may be
slightly different.

00:09:43.550 --> 00:09:45.175 align:middle line:84%
That'll screw up your
whole experiment.

00:09:45.175 --> 00:09:47.480 align:middle line:84%
So typically, instead you
start with a single wafer

00:09:47.480 --> 00:09:49.940 align:middle line:84%
to do an OED experiment,
and you coat part

00:09:49.940 --> 00:09:51.920 align:middle line:84%
of the wafer--
maybe one dye area

00:09:51.920 --> 00:09:53.810 align:middle line:90%
or one small area of the chip.

00:09:53.810 --> 00:09:58.700 align:middle line:84%
You coat it with silicon
nitride so it won't oxidize,

00:09:58.700 --> 00:10:00.560 align:middle line:84%
which is a good
barrier to oxidation.

00:10:00.560 --> 00:10:04.160 align:middle line:84%
And you have down here a
buried layer, some distance--

00:10:04.160 --> 00:10:06.050 align:middle line:90%
maybe half micron or so.

00:10:06.050 --> 00:10:07.730 align:middle line:90%
Could be below the surface.

00:10:07.730 --> 00:10:10.237 align:middle line:84%
A marker layer of some dopant
that's going to diffuse.

00:10:10.237 --> 00:10:12.570 align:middle line:84%
And you're going to measure
the extent that it diffuses.

00:10:12.570 --> 00:10:15.600 align:middle line:84%
So the dark green here is
meant to represent the dopant

00:10:15.600 --> 00:10:17.850 align:middle line:84%
when it starts out at the
beginning of the oxidation.

00:10:17.850 --> 00:10:21.150 align:middle line:84%
The light green is the
edge or the junction

00:10:21.150 --> 00:10:23.800 align:middle line:84%
as it appears after
some time of oxidation.

00:10:23.800 --> 00:10:25.800 align:middle line:84%
And you can see
underneath the region

00:10:25.800 --> 00:10:28.050 align:middle line:84%
where you were doing locals,
where you were locally

00:10:28.050 --> 00:10:31.830 align:middle line:84%
oxidizing the surface, you get a
large spread of the boron layer.

00:10:31.830 --> 00:10:34.440 align:middle line:84%
And this light green
layer is very wide.

00:10:34.440 --> 00:10:37.410 align:middle line:84%
Underneath the inert
surface-- this is called inert

00:10:37.410 --> 00:10:39.840 align:middle line:84%
because there is no
oxidation taking place--

00:10:39.840 --> 00:10:42.280 align:middle line:84%
the boron doesn't
diffuse nearly as much.

00:10:42.280 --> 00:10:43.620 align:middle line:90%
So this is inert diffusion.

00:10:43.620 --> 00:10:46.200 align:middle line:84%
This is OED, oxidation
enhanced, diffusion.

00:10:46.200 --> 00:10:48.930 align:middle line:84%
And also, schematically,
in this cartoon,

00:10:48.930 --> 00:10:51.450 align:middle line:84%
underneath the area
where you're oxidizing,

00:10:51.450 --> 00:10:53.430 align:middle line:84%
the stacking faults,
these defects,

00:10:53.430 --> 00:10:56.100 align:middle line:84%
are growing because they're
adding silicon interstitials

00:10:56.100 --> 00:10:57.750 align:middle line:90%
to the ends of these defects.

00:10:57.750 --> 00:11:01.290 align:middle line:84%
And here they're just staying
put or maybe even shrinking,

00:11:01.290 --> 00:11:04.500 align:middle line:84%
but they're certainly
not growing.

00:11:04.500 --> 00:11:08.340 align:middle line:84%
So the key point is that
people see the enhancement

00:11:08.340 --> 00:11:11.040 align:middle line:84%
of boron diffusion, the
oxidation enhancement,

00:11:11.040 --> 00:11:14.520 align:middle line:84%
under the same conditions that
caused stacking faults to grow.

00:11:14.520 --> 00:11:17.370 align:middle line:84%
And stacking fault
growth is interpreted

00:11:17.370 --> 00:11:20.220 align:middle line:84%
to be injection of interstitials
because people from materials

00:11:20.220 --> 00:11:22.140 align:middle line:84%
point of view believe that the
way you make the stacking fault

00:11:22.140 --> 00:11:23.348 align:middle line:90%
grow is to add interstitials.

00:11:23.348 --> 00:11:25.763 align:middle line:84%
So that's sort of the key
piece of evidence that links.

00:11:25.763 --> 00:11:27.180 align:middle line:84%
It's sort of like
a criminal case.

00:11:27.180 --> 00:11:28.980 align:middle line:84%
You really can never
find the fingerprints,

00:11:28.980 --> 00:11:30.940 align:middle line:84%
but you have some
circumstantial evidence,

00:11:30.940 --> 00:11:35.380 align:middle line:84%
and you put it all together, and
you convict the person on trial.

00:11:35.380 --> 00:11:36.360 align:middle line:90%
It's kind of like that.

00:11:36.360 --> 00:11:37.950 align:middle line:84%
The circumstantial
evidence-- and it's

00:11:37.950 --> 00:11:39.908 align:middle line:84%
reasonably strong-- is
that stacking faults are

00:11:39.908 --> 00:11:41.520 align:middle line:90%
growing when you're oxidizing.

00:11:41.520 --> 00:11:43.320 align:middle line:90%
Boron is also being enhanced.

00:11:43.320 --> 00:11:43.920 align:middle line:90%
Aha.

00:11:43.920 --> 00:11:46.188 align:middle line:84%
Well, interstitials cause
stacking faults to grow.

00:11:46.188 --> 00:11:48.480 align:middle line:84%
Therefore, the interstitials
are probably causing boron

00:11:48.480 --> 00:11:49.920 align:middle line:90%
to diffuse more rapidly.

00:11:49.920 --> 00:11:52.950 align:middle line:84%
That's kind of how
the logic goes.

00:11:52.950 --> 00:11:55.540 align:middle line:84%
Similarly, people have
found that nitridation--

00:11:55.540 --> 00:11:58.500 align:middle line:84%
so that's the reaction
of silicon with ammonia--

00:11:58.500 --> 00:12:00.030 align:middle line:90%
has exactly the opposite effect.

00:12:00.030 --> 00:12:02.370 align:middle line:84%
The boron actually
diffuses slower.

00:12:02.370 --> 00:12:04.650 align:middle line:84%
It's retarded, as we
say in its diffusion.

00:12:04.650 --> 00:12:06.420 align:middle line:84%
And the stacking
faults actually shrink

00:12:06.420 --> 00:12:11.040 align:middle line:90%
relative to inert anneals.

00:12:11.040 --> 00:12:15.060 align:middle line:84%
So people feel that
nitridation injects vacancies.

00:12:15.060 --> 00:12:19.590 align:middle line:84%
And that's how those
simple arguments go.

00:12:19.590 --> 00:12:22.653 align:middle line:84%
So what we say when we want
to get to an atomistic level

00:12:22.653 --> 00:12:24.320 align:middle line:84%
modeling-- and this
is the type of model

00:12:24.320 --> 00:12:28.010 align:middle line:84%
that when you're modeling
the diffusion in SUPREM,

00:12:28.010 --> 00:12:32.660 align:middle line:84%
we say that the dopants diffuse
with a fraction, F sub I.

00:12:32.660 --> 00:12:37.820 align:middle line:84%
So F sub I goes from 0 to 1 of
interstitial type mechanism.

00:12:37.820 --> 00:12:42.110 align:middle line:84%
And a fraction F sub
V, which is 1 minus FI,

00:12:42.110 --> 00:12:43.590 align:middle line:90%
of vacancy type mechanism.

00:12:43.590 --> 00:12:48.500 align:middle line:84%
So we break down its diffusion
coefficient into separate terms.

00:12:48.500 --> 00:12:51.800 align:middle line:84%
There's one term, which
is proportional to F sub I

00:12:51.800 --> 00:12:54.770 align:middle line:90%
times CI over CI star.

00:12:54.770 --> 00:12:56.850 align:middle line:84%
So again, F sub I,
it goes from 0 to 1.

00:12:56.850 --> 00:12:59.690 align:middle line:84%
If you believe the dopant only
diffuses with interstitials

00:12:59.690 --> 00:13:01.310 align:middle line:84%
and vacancies are
insignificant, you

00:13:01.310 --> 00:13:03.830 align:middle line:84%
would make F sub I equal to
1, like the case of boron

00:13:03.830 --> 00:13:06.410 align:middle line:90%
or phosphorus.

00:13:06.410 --> 00:13:08.240 align:middle line:84%
And then this term
becomes negligible.

00:13:08.240 --> 00:13:10.010 align:middle line:84%
If you believe that
it only diffuses

00:13:10.010 --> 00:13:13.160 align:middle line:84%
with vacancies like antimony,
you'd make F sub V close to 1.

00:13:13.160 --> 00:13:16.010 align:middle line:84%
If you think it's
both, well, then you

00:13:16.010 --> 00:13:17.600 align:middle line:90%
apportion it accordingly.

00:13:17.600 --> 00:13:19.130 align:middle line:84%
And how do you
figure out F sub I

00:13:19.130 --> 00:13:20.570 align:middle line:90%
and F sub V, those proportions?

00:13:20.570 --> 00:13:23.450 align:middle line:84%
Well, you subject the
dopant in the silicon

00:13:23.450 --> 00:13:26.930 align:middle line:84%
to different circumstances of
injecting vacancies or injecting

00:13:26.930 --> 00:13:30.230 align:middle line:84%
interstitials and seeing how
much the diffusivity goes up

00:13:30.230 --> 00:13:32.262 align:middle line:90%
or down under those conditions.

00:13:32.262 --> 00:13:34.220 align:middle line:84%
And that's what people
have done over the years

00:13:34.220 --> 00:13:38.380 align:middle line:84%
to try to nail down
F sub I and F sub V.

00:13:38.380 --> 00:13:41.200 align:middle line:84%
So the DA here is the
effective diffusivity.

00:13:41.200 --> 00:13:43.480 align:middle line:84%
Now, it's being measured
under any condition,

00:13:43.480 --> 00:13:44.860 align:middle line:84%
but particularly
under conditions

00:13:44.860 --> 00:13:47.140 align:middle line:84%
where the point
defect populations are

00:13:47.140 --> 00:13:48.610 align:middle line:90%
disturbed or perturbed.

00:13:48.610 --> 00:13:51.460 align:middle line:84%
So this would be during
oxidation or nitridation.

00:13:51.460 --> 00:13:52.397 align:middle line:90%
DA star.

00:13:52.397 --> 00:13:53.230 align:middle line:90%
What does that mean?

00:13:53.230 --> 00:13:56.170 align:middle line:84%
That's the normal
equilibrium diffusivity

00:13:56.170 --> 00:13:59.720 align:middle line:84%
of the dopant, measured
under inert conditions.

00:13:59.720 --> 00:14:01.878 align:middle line:84%
So again, when we're
talking about diffusion

00:14:01.878 --> 00:14:03.670 align:middle line:84%
and we're talking about
inert, what we mean

00:14:03.670 --> 00:14:06.370 align:middle line:90%
is no oxidation, no nitridation.

00:14:06.370 --> 00:14:09.490 align:middle line:84%
Inert means nothing that
injects excess point

00:14:09.490 --> 00:14:13.670 align:middle line:90%
defects into the bulk.

00:14:13.670 --> 00:14:17.840 align:middle line:84%
So by using this equation, you
can understand how to model OED.

00:14:17.840 --> 00:14:23.530 align:middle line:84%
What happens in OED is
this term, CI over CI star.

00:14:23.530 --> 00:14:28.078 align:middle line:84%
The interstitial equilibrium--
the interstitial population

00:14:28.078 --> 00:14:29.620 align:middle line:84%
relative to what it
is in equilibrium

00:14:29.620 --> 00:14:31.840 align:middle line:84%
goes up by some
fraction, some amount.

00:14:31.840 --> 00:14:33.580 align:middle line:90%
Could be five, ten times higher.

00:14:33.580 --> 00:14:38.170 align:middle line:84%
That causes the diffusivity to
be enhanced by 5 to 10 times.

00:14:38.170 --> 00:14:40.930 align:middle line:84%
In addition, because of
recombination-- interstitials

00:14:40.930 --> 00:14:43.960 align:middle line:84%
and vacancies can recombine-- if
you pump up the interstitials,

00:14:43.960 --> 00:14:45.380 align:middle line:90%
the vacancy is going to go down.

00:14:45.380 --> 00:14:48.640 align:middle line:84%
So this term can actually
go down to a certain extent.

00:14:48.640 --> 00:14:50.230 align:middle line:84%
And that's how
the model accounts

00:14:50.230 --> 00:14:54.280 align:middle line:84%
for OED or for nitridation
retardant diffusion

00:14:54.280 --> 00:14:56.060 align:middle line:84%
because nitrogen does
just the opposite.

00:14:56.060 --> 00:14:59.890 align:middle line:84%
It enhances the CV over CV
star and suppresses this term.

00:14:59.890 --> 00:15:03.100 align:middle line:84%
And depending on your dopant,
your FI and your FV values,

00:15:03.100 --> 00:15:06.040 align:middle line:84%
it will have more or less
of an effect on diffusivity.

00:15:06.040 --> 00:15:11.440 align:middle line:84%
And that gets modeled
in the simulations.

00:15:11.440 --> 00:15:14.380 align:middle line:84%
I actually pulled out of the
literature some data just

00:15:14.380 --> 00:15:18.430 align:middle line:84%
to show you some of the classic
experiments that took place

00:15:18.430 --> 00:15:21.760 align:middle line:84%
quite some time ago on
people trying to determine

00:15:21.760 --> 00:15:23.350 align:middle line:90%
F sub I and F sub V.

00:15:23.350 --> 00:15:25.720 align:middle line:84%
And this is a paper by--
it's a review article.

00:15:25.720 --> 00:15:26.420 align:middle line:90%
It's quite long.

00:15:26.420 --> 00:15:28.810 align:middle line:84%
It's many pages by Fahey,
Griffin, and Plummer.

00:15:28.810 --> 00:15:30.280 align:middle line:90%
It's getting older.

00:15:30.280 --> 00:15:34.210 align:middle line:84%
It was published back
in 1989, but that

00:15:34.210 --> 00:15:36.550 align:middle line:84%
was sort of at the
height of people

00:15:36.550 --> 00:15:39.100 align:middle line:84%
really coalescing all this
data on these atomic scale

00:15:39.100 --> 00:15:40.130 align:middle line:90%
mechanisms.

00:15:40.130 --> 00:15:42.100 align:middle line:84%
So it's a good
review article if you

00:15:42.100 --> 00:15:43.840 align:middle line:84%
want to understand
in more detail

00:15:43.840 --> 00:15:45.820 align:middle line:84%
than is given in
your text about this.

00:15:45.820 --> 00:15:48.320 align:middle line:84%
Since that time, of course,
there have been new discoveries,

00:15:48.320 --> 00:15:50.170 align:middle line:84%
and we'll talk about
those newer discoveries

00:15:50.170 --> 00:15:52.420 align:middle line:90%
when we talk about TED.

00:15:52.420 --> 00:15:55.300 align:middle line:84%
But what people did was--
this is particular data

00:15:55.300 --> 00:15:56.920 align:middle line:90%
I took from Fahey's article.

00:15:56.920 --> 00:15:59.150 align:middle line:84%
This is an experiment
on nitridation.

00:15:59.150 --> 00:16:02.440 align:middle line:84%
So you're flowing ammonia
at very high temperatures.

00:16:02.440 --> 00:16:05.530 align:middle line:84%
Ammonia doesn't react
at as low temperatures

00:16:05.530 --> 00:16:07.340 align:middle line:90%
as oxygen does with the surface.

00:16:07.340 --> 00:16:09.590 align:middle line:84%
So you kind of have to go
to pretty high temperatures.

00:16:09.590 --> 00:16:12.560 align:middle line:84%
That's one disadvantage
of nitridation.

00:16:12.560 --> 00:16:14.600 align:middle line:84%
So you typically see
nitrogen experiments--

00:16:14.600 --> 00:16:19.740 align:middle line:84%
900, 1,000, 1,100-- in order
to get reasonable injection.

00:16:19.740 --> 00:16:22.430 align:middle line:84%
So under nitridation,
1,100 degrees c and there

00:16:22.430 --> 00:16:24.870 align:middle line:84%
are three different dopants
studied here-- phosphorus,

00:16:24.870 --> 00:16:26.790 align:middle line:90%
arsenic, and antimony.

00:16:26.790 --> 00:16:29.960 align:middle line:84%
And this axis here
shows the time

00:16:29.960 --> 00:16:32.382 align:middle line:84%
averaged because they
do diffusion experiments

00:16:32.382 --> 00:16:33.590 align:middle line:90%
for a certain amount of time.

00:16:33.590 --> 00:16:36.770 align:middle line:84%
Here you could do it for half
an hour or five hours, 10 hours,

00:16:36.770 --> 00:16:37.550 align:middle line:90%
20 hours.

00:16:37.550 --> 00:16:40.400 align:middle line:84%
And you take the time
averaged enhancement,

00:16:40.400 --> 00:16:43.250 align:middle line:84%
or time averaged diffusivity,
that you get averaged

00:16:43.250 --> 00:16:44.870 align:middle line:90%
over that time interval.

00:16:44.870 --> 00:16:49.580 align:middle line:84%
And you divide it by DA
star, so the equilibrium,

00:16:49.580 --> 00:16:51.800 align:middle line:84%
the diffusion coefficient
measured right next to it

00:16:51.800 --> 00:16:55.860 align:middle line:84%
in the stripe right next
to it in the inert case.

00:16:55.860 --> 00:17:01.280 align:middle line:84%
So if I go a couple slides
back to slide 3, so the DA star

00:17:01.280 --> 00:17:03.740 align:middle line:84%
they measured right
over here by measuring

00:17:03.740 --> 00:17:05.849 align:middle line:84%
the amount of diffusion
underneath this region,

00:17:05.849 --> 00:17:07.760 align:middle line:84%
the inert region,
and the DA time

00:17:07.760 --> 00:17:10.730 align:middle line:84%
average they measured over
here under either oxidation

00:17:10.730 --> 00:17:11.390 align:middle line:90%
or nitridation.

00:17:11.390 --> 00:17:13.819 align:middle line:84%
This particular
one is nitridation.

00:17:13.819 --> 00:17:17.390 align:middle line:84%
And so if you look
at these dopants--

00:17:17.390 --> 00:17:18.890 align:middle line:90%
look at antimony here.

00:17:18.890 --> 00:17:23.210 align:middle line:84%
What you see pretty much at
all times, DA over DA star

00:17:23.210 --> 00:17:25.609 align:middle line:90%
is enhanced under nitridation.

00:17:25.609 --> 00:17:30.170 align:middle line:84%
So antimony has a strong
dependence on the excess vacancy

00:17:30.170 --> 00:17:31.420 align:middle line:90%
population.

00:17:31.420 --> 00:17:36.620 align:middle line:84%
And that's how people came to
eventually give antimony an F

00:17:36.620 --> 00:17:39.140 align:middle line:90%
sub V number that's close to 1.

00:17:39.140 --> 00:17:42.950 align:middle line:84%
Arsenic has some effect,
but not very much.

00:17:42.950 --> 00:17:44.810 align:middle line:84%
What happens in the
case of phosphorus?

00:17:44.810 --> 00:17:48.440 align:middle line:84%
Actually, we do nitridation
and we inject vacancies.

00:17:48.440 --> 00:17:51.920 align:middle line:84%
Phosphorus diffusion over
time is actually slowing down.

00:17:51.920 --> 00:17:54.280 align:middle line:90%
It's actually retarded?

00:17:54.280 --> 00:17:55.190 align:middle line:90%
Now, how can that be?

00:17:55.190 --> 00:17:57.730 align:middle line:84%
Well, let's say
phosphorus doesn't diffuse

00:17:57.730 --> 00:18:00.100 align:middle line:84%
by vacancy mechanism, but
it diffuses almost entirely

00:18:00.100 --> 00:18:01.180 align:middle line:90%
by interstitials.

00:18:01.180 --> 00:18:03.850 align:middle line:84%
As I inject vacancies
you say, well, then it

00:18:03.850 --> 00:18:06.370 align:middle line:84%
shouldn't have any effect,
but it does via recombination.

00:18:06.370 --> 00:18:08.200 align:middle line:84%
Excess vacancies
recombine and they

00:18:08.200 --> 00:18:11.560 align:middle line:84%
reduce the
interstitial population

00:18:11.560 --> 00:18:14.140 align:middle line:84%
lower than it would
be in equilibrium.

00:18:14.140 --> 00:18:15.970 align:middle line:84%
And that lower
interstitial population

00:18:15.970 --> 00:18:17.450 align:middle line:84%
lowers the diffusion
coefficient.

00:18:17.450 --> 00:18:21.220 align:middle line:84%
And so for phosphorus,
this gives us a hint

00:18:21.220 --> 00:18:24.190 align:middle line:84%
that F sub I is probably
pretty close to one.

00:18:24.190 --> 00:18:27.250 align:middle line:84%
Then you can do the
analogous experiment

00:18:27.250 --> 00:18:29.890 align:middle line:84%
with these same
dopants with oxidation

00:18:29.890 --> 00:18:34.743 align:middle line:84%
and see how it reacts during
injection of interstitials.

00:18:34.743 --> 00:18:36.160 align:middle line:84%
And between those
two experiments,

00:18:36.160 --> 00:18:38.118 align:middle line:84%
you try to get an estimate
of what this F sub I

00:18:38.118 --> 00:18:40.610 align:middle line:90%
and F sub V value could be.

00:18:40.610 --> 00:18:44.890 align:middle line:84%
So those are some classic
experiments people have done.

00:18:44.890 --> 00:18:48.940 align:middle line:84%
And in fact, also on
the next slide, slide 6,

00:18:48.940 --> 00:18:50.710 align:middle line:84%
I've taken a table
from that paper

00:18:50.710 --> 00:18:53.380 align:middle line:84%
that just summarizes
at that time what

00:18:53.380 --> 00:18:55.960 align:middle line:84%
was known at the state of
the art of the interface

00:18:55.960 --> 00:18:57.730 align:middle line:84%
processes at the
surface and how they

00:18:57.730 --> 00:19:00.580 align:middle line:84%
affect the diffusion
of different dopants

00:19:00.580 --> 00:19:02.500 align:middle line:84%
under different
conditions, and also

00:19:02.500 --> 00:19:05.730 align:middle line:90%
how they affect stacking faults.

00:19:05.730 --> 00:19:07.120 align:middle line:90%
There are three columns here.

00:19:07.120 --> 00:19:09.330 align:middle line:84%
The first and the last,
we've already talked about.

00:19:09.330 --> 00:19:12.120 align:middle line:84%
Oxidation injects
interstitials, causes

00:19:12.120 --> 00:19:15.060 align:middle line:84%
vacancies, population to go
down, stacking faults grow.

00:19:15.060 --> 00:19:18.720 align:middle line:84%
The right column in nitridation,
interstitial population

00:19:18.720 --> 00:19:23.040 align:middle line:84%
goes down, vacancies go up,
and stacking faults shrink.

00:19:23.040 --> 00:19:24.540 align:middle line:84%
And for either one
of these columns,

00:19:24.540 --> 00:19:27.390 align:middle line:84%
you can see what happens,
say, to phosphorus and boron

00:19:27.390 --> 00:19:28.830 align:middle line:90%
diffusion.

00:19:28.830 --> 00:19:32.100 align:middle line:84%
Now he's sort of broken this
out to intrinsic diffusion

00:19:32.100 --> 00:19:34.920 align:middle line:84%
when n is less than
or equal to NI,

00:19:34.920 --> 00:19:36.510 align:middle line:90%
or extrinsic when it's higher.

00:19:36.510 --> 00:19:39.450 align:middle line:84%
In either case, when
you do oxidation,

00:19:39.450 --> 00:19:42.930 align:middle line:84%
phosphorus and
boron are enhanced.

00:19:42.930 --> 00:19:46.593 align:middle line:84%
Antimony is a little
tricky, actually.

00:19:46.593 --> 00:19:48.510 align:middle line:84%
There's a little bit of
enhancement initially.

00:19:48.510 --> 00:19:51.480 align:middle line:84%
But overall, the effect
is believed to be retarded

00:19:51.480 --> 00:19:54.690 align:middle line:90%
or slowed down.

00:19:54.690 --> 00:19:57.210 align:middle line:84%
Arsenic is a tough one,
because again, its F sub I

00:19:57.210 --> 00:19:59.820 align:middle line:84%
value is going to be close
to half, it turns out.

00:19:59.820 --> 00:20:03.370 align:middle line:84%
It can be enhanced
to a certain extent,

00:20:03.370 --> 00:20:05.560 align:middle line:84%
depending on if it's
intrinsic or extrinsic,

00:20:05.560 --> 00:20:07.270 align:middle line:84%
it can be retarded,
so it's a little bit

00:20:07.270 --> 00:20:10.570 align:middle line:90%
tricky under oxidation.

00:20:10.570 --> 00:20:14.620 align:middle line:84%
Arsenic also is enhanced
under nitrogen. So it's tough.

00:20:14.620 --> 00:20:17.350 align:middle line:84%
That's why we believe
that F sub I and F sub

00:20:17.350 --> 00:20:19.142 align:middle line:84%
v are somewhat equally
weighted, depending

00:20:19.142 --> 00:20:20.350 align:middle line:90%
on the amount of enhancement.

00:20:20.350 --> 00:20:21.517 align:middle line:90%
It's enhanced in both cases.

00:20:21.517 --> 00:20:24.100 align:middle line:90%


00:20:24.100 --> 00:20:26.490 align:middle line:84%
Boron's easier to understand
because it's pure.

00:20:26.490 --> 00:20:28.840 align:middle line:84%
It's enhanced under
oxidation, but it's

00:20:28.840 --> 00:20:30.010 align:middle line:90%
retarded under nitridation.

00:20:30.010 --> 00:20:33.610 align:middle line:84%
So people have concluded
based on a lot of data

00:20:33.610 --> 00:20:35.530 align:middle line:90%
that the F sub I is close to 1.

00:20:35.530 --> 00:20:37.450 align:middle line:84%
Now, there's one other
column in the middle

00:20:37.450 --> 00:20:39.705 align:middle line:84%
that we didn't talk
about in this class,

00:20:39.705 --> 00:20:41.830 align:middle line:84%
and I don't think it's
mentioned much in your text.

00:20:41.830 --> 00:20:43.780 align:middle line:84%
But Fahey talks about
it in this article.

00:20:43.780 --> 00:20:45.650 align:middle line:90%
It's called oxynitridation.

00:20:45.650 --> 00:20:47.740 align:middle line:90%
It's a little bit trickier.

00:20:47.740 --> 00:20:49.690 align:middle line:84%
Oxynitridation
refers to the fact

00:20:49.690 --> 00:20:52.920 align:middle line:84%
that if you start
with a thin oxide--

00:20:52.920 --> 00:20:54.870 align:middle line:84%
so you have a thin
oxide on the surface,

00:20:54.870 --> 00:20:56.190 align:middle line:90%
and then you nitride that.

00:20:56.190 --> 00:21:00.450 align:middle line:84%
You subject it to a
high-temperature ammonia.

00:21:00.450 --> 00:21:03.600 align:middle line:84%
You are doing something
called [INAUDIBLE]..

00:21:03.600 --> 00:21:06.720 align:middle line:84%
You're growing something
called oxynitride.

00:21:06.720 --> 00:21:08.250 align:middle line:90%
It's not pure nitride.

00:21:08.250 --> 00:21:10.450 align:middle line:90%
It's not pure silicon dioxide.

00:21:10.450 --> 00:21:12.720 align:middle line:84%
It's kind of got both
silicon oxygen and nitrogen.

00:21:12.720 --> 00:21:14.550 align:middle line:90%
And so people believe--

00:21:14.550 --> 00:21:16.105 align:middle line:84%
because stacking
faults, grow people

00:21:16.105 --> 00:21:17.730 align:middle line:84%
believe that
interstitials are injected

00:21:17.730 --> 00:21:19.740 align:middle line:84%
and that vacancy
population goes down.

00:21:19.740 --> 00:21:23.310 align:middle line:84%
But it's another marker,
another process people use.

00:21:23.310 --> 00:21:27.520 align:middle line:84%
It's a little bit harder,
in some ways, to interpret.

00:21:27.520 --> 00:21:29.685 align:middle line:84%
So that's a summary of
some of their classic data.

00:21:29.685 --> 00:21:32.440 align:middle line:90%


00:21:32.440 --> 00:21:34.810 align:middle line:84%
If I go on to
slide 7, now I want

00:21:34.810 --> 00:21:38.290 align:middle line:84%
to talk about what I think are
some very clever experiments.

00:21:38.290 --> 00:21:40.120 align:middle line:84%
What we've talked
about so far when

00:21:40.120 --> 00:21:41.808 align:middle line:84%
I've been showing
this cartoon, I've

00:21:41.808 --> 00:21:43.600 align:middle line:84%
been showing talking
about one-dimensional.

00:21:43.600 --> 00:21:46.060 align:middle line:84%
So I've been
assuming I'm very far

00:21:46.060 --> 00:21:50.680 align:middle line:84%
from the interface between the
neutral or the inert ambient

00:21:50.680 --> 00:21:54.337 align:middle line:90%
and the reactive surface.

00:21:54.337 --> 00:21:56.920 align:middle line:84%
So far I haven't talked about
what happens near the interface.

00:21:56.920 --> 00:21:59.890 align:middle line:84%
But you know as you're
injecting the interstitials here

00:21:59.890 --> 00:22:02.890 align:middle line:84%
due to the oxidation, they don't
just diffuse straight down.

00:22:02.890 --> 00:22:05.680 align:middle line:84%
They diffuse out in a
two-dimensional fashion.

00:22:05.680 --> 00:22:08.410 align:middle line:84%
They diffuse down,
sideways, over to the edge.

00:22:08.410 --> 00:22:11.570 align:middle line:84%
So they're actually diffusing
in different directions.

00:22:11.570 --> 00:22:14.050 align:middle line:84%
Now, if you're far
from this edge,

00:22:14.050 --> 00:22:16.670 align:middle line:84%
you don't see much effect
of the interstitial.

00:22:16.670 --> 00:22:18.320 align:middle line:90%
They primarily go down.

00:22:18.320 --> 00:22:19.900 align:middle line:84%
But if you're near
the edge here,

00:22:19.900 --> 00:22:21.940 align:middle line:84%
you're going to see
some edge effects.

00:22:21.940 --> 00:22:27.850 align:middle line:84%
And in fact, depending on
how far from this stripe

00:22:27.850 --> 00:22:30.925 align:middle line:84%
the enhancement of
the oxidation occurs

00:22:30.925 --> 00:22:34.390 align:middle line:84%
will give you some idea of how
rapidly the interstitials are

00:22:34.390 --> 00:22:37.510 align:middle line:84%
diffusing in this
lateral direction.

00:22:37.510 --> 00:22:39.910 align:middle line:84%
But there's another process
besides just the fact

00:22:39.910 --> 00:22:41.860 align:middle line:84%
that the interstitials
are diffusing around.

00:22:41.860 --> 00:22:44.830 align:middle line:84%
So they're going
vertically and laterally.

00:22:44.830 --> 00:22:46.750 align:middle line:84%
One other process
is recombination

00:22:46.750 --> 00:22:48.080 align:middle line:90%
that we have to consider.

00:22:48.080 --> 00:22:51.610 align:middle line:84%
So in fact, the interstitial
flux into the surface

00:22:51.610 --> 00:22:54.082 align:middle line:84%
is the difference between
the generation rate.

00:22:54.082 --> 00:22:55.790 align:middle line:84%
There's a certain
number of interstitials

00:22:55.790 --> 00:22:57.170 align:middle line:90%
being generated per unit time.

00:22:57.170 --> 00:23:00.870 align:middle line:84%
That's G. There's a certain
number of interstitials

00:23:00.870 --> 00:23:03.720 align:middle line:84%
being recombined at the
surface per unit time.

00:23:03.720 --> 00:23:04.590 align:middle line:90%
That's R.

00:23:04.590 --> 00:23:07.380 align:middle line:84%
The net flux of
interstitials injected is--

00:23:07.380 --> 00:23:10.050 align:middle line:84%
you can think of the net flux
is if G and R are fluxes,

00:23:10.050 --> 00:23:14.250 align:middle line:84%
it's G minus R. OK,
now, the problem is--

00:23:14.250 --> 00:23:16.170 align:middle line:84%
and we know that the
generation rate here

00:23:16.170 --> 00:23:18.450 align:middle line:84%
is proportional to
the oxidation rate.

00:23:18.450 --> 00:23:21.930 align:middle line:84%
But the question is, in your
mind, the recombination rate

00:23:21.930 --> 00:23:25.500 align:middle line:84%
at this point here at this
interface is not necessarily

00:23:25.500 --> 00:23:27.630 align:middle line:84%
the same-- at the active
oxidizing interface

00:23:27.630 --> 00:23:30.060 align:middle line:84%
is not necessarily the
same as the recombination

00:23:30.060 --> 00:23:31.640 align:middle line:90%
rate at the inert interface.

00:23:31.640 --> 00:23:33.390 align:middle line:84%
For one thing, this
interface is changing.

00:23:33.390 --> 00:23:35.580 align:middle line:84%
It's continuously
reacting and oxidizing.

00:23:35.580 --> 00:23:39.718 align:middle line:84%
So it's not clear that R should
be the same here as it is here

00:23:39.718 --> 00:23:40.260 align:middle line:90%
in the inert.

00:23:40.260 --> 00:23:43.440 align:middle line:84%
And in fact, it's not
necessarily the same.

00:23:43.440 --> 00:23:45.910 align:middle line:84%
Depending on the reaction,
it can be quite different.

00:23:45.910 --> 00:23:49.170 align:middle line:84%
So when in SUPREM, you'll
see various parameters.

00:23:49.170 --> 00:23:51.600 align:middle line:84%
There'll be a diffusivity
for a silicon interstitial.

00:23:51.600 --> 00:23:52.680 align:middle line:90%
You need to know that.

00:23:52.680 --> 00:23:54.510 align:middle line:84%
There'll also be a
recombination rate.

00:23:54.510 --> 00:23:56.880 align:middle line:84%
Sometimes they call
it K sub S. There'll

00:23:56.880 --> 00:24:00.850 align:middle line:84%
be a recombination constant
associated with this oxidizing

00:24:00.850 --> 00:24:01.600 align:middle line:90%
interface.

00:24:01.600 --> 00:24:04.360 align:middle line:84%
And there'll be another
recombination constant

00:24:04.360 --> 00:24:07.510 align:middle line:84%
associated with the
inert interface.

00:24:07.510 --> 00:24:09.760 align:middle line:84%
And they'll also be
bulk recombination.

00:24:09.760 --> 00:24:12.230 align:middle line:84%
We need to know those three
parameters if we're really

00:24:12.230 --> 00:24:14.800 align:middle line:84%
going to understand
what this lateral extent

00:24:14.800 --> 00:24:16.780 align:middle line:84%
of the oxidation-enhanced
diffusion

00:24:16.780 --> 00:24:19.390 align:middle line:84%
looks like because after all,
if I'm getting a lot of surface

00:24:19.390 --> 00:24:22.630 align:middle line:84%
recombination over here,
interstitials injected,

00:24:22.630 --> 00:24:25.490 align:middle line:84%
basically, they all get sucked
into that surface and recombine.

00:24:25.490 --> 00:24:27.880 align:middle line:84%
So the net excess
interstitial population

00:24:27.880 --> 00:24:30.810 align:middle line:90%
will fall off more rapidly.

00:24:30.810 --> 00:24:33.480 align:middle line:84%
And here's an example on the
right of a test structure

00:24:33.480 --> 00:24:36.180 align:middle line:84%
that people came up
with to try to study

00:24:36.180 --> 00:24:37.180 align:middle line:90%
two-dimensional effects.

00:24:37.180 --> 00:24:40.920 align:middle line:84%
And I think it's kind of
a neat test structure.

00:24:40.920 --> 00:24:43.170 align:middle line:84%
This is in cross-section
now, so it's a little tricky.

00:24:43.170 --> 00:24:45.253 align:middle line:84%
But I'm looking at three
different cross-sections.

00:24:45.253 --> 00:24:47.220 align:middle line:84%
So this is the
surface of the sample.

00:24:47.220 --> 00:24:52.610 align:middle line:84%
This is a phosphorous junction
that was initially diffused in.

00:24:52.610 --> 00:24:55.280 align:middle line:84%
So it has a starting junction
depth, say of half a micron,

00:24:55.280 --> 00:24:55.850 align:middle line:90%
whatever.

00:24:55.850 --> 00:24:57.830 align:middle line:84%
Phosphorous diffused
into lightly doped boron.

00:24:57.830 --> 00:25:00.620 align:middle line:84%
And they put stripes
on the sample.

00:25:00.620 --> 00:25:04.640 align:middle line:84%
And the stripes are masked
such that the open region where

00:25:04.640 --> 00:25:07.880 align:middle line:84%
they cut away the nitride,
these open regions,

00:25:07.880 --> 00:25:10.263 align:middle line:84%
these open stripes, are
getting smaller and smaller

00:25:10.263 --> 00:25:11.430 align:middle line:90%
as we go from left to right.

00:25:11.430 --> 00:25:15.020 align:middle line:84%
So here's a pretty wide open
region, narrower, narrower,

00:25:15.020 --> 00:25:19.170 align:middle line:84%
until it gets to the point where
it's a very narrow open region.

00:25:19.170 --> 00:25:21.500 align:middle line:84%
So the nice thing
is, what you're doing

00:25:21.500 --> 00:25:25.700 align:middle line:84%
is you're sort of changing
the region over which

00:25:25.700 --> 00:25:28.860 align:middle line:90%
you inject these point defects.

00:25:28.860 --> 00:25:31.028 align:middle line:90%
And then they did the oxidation.

00:25:31.028 --> 00:25:32.570 align:middle line:84%
They did the oxidation
of phosphorus.

00:25:32.570 --> 00:25:34.970 align:middle line:84%
And what they see is
the junction depth now,

00:25:34.970 --> 00:25:39.290 align:middle line:84%
which initially was flat because
it was diffused originally

00:25:39.290 --> 00:25:40.940 align:middle line:84%
before they put
the stripes down,

00:25:40.940 --> 00:25:43.520 align:middle line:84%
after they put the stripes
down and they do oxidation,

00:25:43.520 --> 00:25:46.797 align:middle line:84%
right underneath where the
oxidation takes place, of course

00:25:46.797 --> 00:25:48.630 align:middle line:84%
you see a big enhancement
of the phosphorus.

00:25:48.630 --> 00:25:49.830 align:middle line:90%
That's OED.

00:25:49.830 --> 00:25:53.490 align:middle line:84%
But interestingly,
look at the shape

00:25:53.490 --> 00:25:58.680 align:middle line:84%
as you go to different opening
widths of these open stripes.

00:25:58.680 --> 00:26:00.960 align:middle line:84%
The overall junction
depth kind of

00:26:00.960 --> 00:26:04.410 align:middle line:84%
reaches the same
point here, regardless

00:26:04.410 --> 00:26:07.860 align:middle line:90%
of the width of the open area.

00:26:07.860 --> 00:26:10.110 align:middle line:84%
It's changing a
little bit in shape.

00:26:10.110 --> 00:26:13.980 align:middle line:84%
But nevertheless, it reaches
the same junction depth.

00:26:13.980 --> 00:26:16.650 align:middle line:84%
So what that's saying is
that at this point down here,

00:26:16.650 --> 00:26:19.230 align:middle line:84%
the interstitial concentration
or supersaturation

00:26:19.230 --> 00:26:22.210 align:middle line:84%
at the little tip here is
about the same as it is here.

00:26:22.210 --> 00:26:24.550 align:middle line:84%
It's about the same as
it here, as it is here.

00:26:24.550 --> 00:26:26.730 align:middle line:84%
And so it's not
that much perturbed

00:26:26.730 --> 00:26:30.420 align:middle line:84%
by the presence of, all
around it, these interfaces,

00:26:30.420 --> 00:26:32.860 align:middle line:90%
these inert interfaces.

00:26:32.860 --> 00:26:37.045 align:middle line:84%
So the recombination probably
at the oxidizing interface

00:26:37.045 --> 00:26:38.670 align:middle line:84%
and at the inert
interface, those rates

00:26:38.670 --> 00:26:41.253 align:middle line:84%
are probably fairly
comparable when you're

00:26:41.253 --> 00:26:42.420 align:middle line:90%
talking about interstitials.

00:26:42.420 --> 00:26:44.710 align:middle line:84%
But let's look at
the other case.

00:26:44.710 --> 00:26:45.765 align:middle line:90%
Here's another example.

00:26:45.765 --> 00:26:47.140 align:middle line:84%
They did an
experiment like that,

00:26:47.140 --> 00:26:49.750 align:middle line:84%
but instead they started
with an antimony junction.

00:26:49.750 --> 00:26:52.800 align:middle line:84%
So this initial starting
junction depth looks similar,

00:26:52.800 --> 00:26:53.760 align:middle line:90%
but it was antimony.

00:26:53.760 --> 00:26:56.490 align:middle line:84%
And what do they see as they
decrease the opening width?

00:26:56.490 --> 00:26:59.850 align:middle line:84%
In fact, the overall
junction depth,

00:26:59.850 --> 00:27:02.250 align:middle line:84%
even right below the
opening, directly below it,

00:27:02.250 --> 00:27:04.630 align:middle line:90%
actually goes down.

00:27:04.630 --> 00:27:06.400 align:middle line:84%
This is for nitridation
of antimony.

00:27:06.400 --> 00:27:08.590 align:middle line:84%
Unlike here, where
these tips all stay--

00:27:08.590 --> 00:27:11.620 align:middle line:84%
the end of the junction was the
same regardless of stripe width.

00:27:11.620 --> 00:27:13.520 align:middle line:90%
Here it's actually going down.

00:27:13.520 --> 00:27:14.607 align:middle line:90%
So what's that saying?

00:27:14.607 --> 00:27:15.940 align:middle line:90%
That's a two-dimensional effect.

00:27:15.940 --> 00:27:18.490 align:middle line:84%
That's actually saying that
directly below this opening

00:27:18.490 --> 00:27:20.350 align:middle line:84%
where the nitridation
is taking place,

00:27:20.350 --> 00:27:23.020 align:middle line:84%
locally the supersaturation
of vacancies

00:27:23.020 --> 00:27:26.810 align:middle line:84%
is actually smaller than below
an opening that's much wider.

00:27:26.810 --> 00:27:29.380 align:middle line:84%
So these supersaturation
of vacancies

00:27:29.380 --> 00:27:32.350 align:middle line:84%
must be being impacted
by recombination

00:27:32.350 --> 00:27:35.020 align:middle line:84%
that's taking place on
either side of that opening.

00:27:35.020 --> 00:27:38.380 align:middle line:84%
And in fact, people believe
that the vacancy recombination

00:27:38.380 --> 00:27:41.140 align:middle line:84%
rate here at these
inert interfaces

00:27:41.140 --> 00:27:44.630 align:middle line:84%
is a lot faster than it is
at the nitriding interface.

00:27:44.630 --> 00:27:48.310 align:middle line:84%
And so the vacancy
supersaturation level

00:27:48.310 --> 00:27:50.350 align:middle line:84%
is actually impacted
at the center point

00:27:50.350 --> 00:27:52.550 align:middle line:84%
by what's happening
all around it.

00:27:52.550 --> 00:27:55.330 align:middle line:84%
So it's a two-dimensional
diffusion and recombination

00:27:55.330 --> 00:27:56.050 align:middle line:90%
problem.

00:27:56.050 --> 00:27:57.757 align:middle line:84%
And there are a
number of parameters.

00:27:57.757 --> 00:27:59.590 align:middle line:84%
There's the diffusivity
of the point defect.

00:27:59.590 --> 00:28:01.540 align:middle line:84%
There's recombination
at this surface.

00:28:01.540 --> 00:28:05.357 align:middle line:84%
There's recombination
at the reactant surface.

00:28:05.357 --> 00:28:06.940 align:middle line:84%
And there's recombination
in the bowl.

00:28:06.940 --> 00:28:09.700 align:middle line:84%
So it's kind of a neat
way of looking at things,

00:28:09.700 --> 00:28:12.130 align:middle line:84%
even with a one-dimensional
test structure--

00:28:12.130 --> 00:28:14.410 align:middle line:84%
I mean, all we have
is one dimension here

00:28:14.410 --> 00:28:17.820 align:middle line:84%
that we can measure,
essentially, the junction depth.

00:28:17.820 --> 00:28:19.570 align:middle line:84%
But we can get
two-dimensional information

00:28:19.570 --> 00:28:23.260 align:middle line:90%
by changing the stripe, period.

00:28:23.260 --> 00:28:26.070 align:middle line:84%
So actually, if you go
on to slide number 8,

00:28:26.070 --> 00:28:28.080 align:middle line:84%
I also took this
from that same paper

00:28:28.080 --> 00:28:29.760 align:middle line:90%
by Fahey, Griffin, and Plummer.

00:28:29.760 --> 00:28:34.590 align:middle line:84%
And this is a little more
quantitative description

00:28:34.590 --> 00:28:36.690 align:middle line:84%
where they've actually
done diffusion modeling

00:28:36.690 --> 00:28:38.070 align:middle line:84%
of this two-dimensional
diffusion

00:28:38.070 --> 00:28:40.362 align:middle line:84%
problem, two-dimensional
diffusion of the interstitials

00:28:40.362 --> 00:28:43.320 align:middle line:84%
being injected and recombining,
and what effect they would

00:28:43.320 --> 00:28:46.310 align:middle line:90%
have on a dopant diffusion.

00:28:46.310 --> 00:28:48.940 align:middle line:84%
So it's a little bit tricky
here, but what you're doing

00:28:48.940 --> 00:28:50.440 align:middle line:90%
is a local oxidation.

00:28:50.440 --> 00:28:52.460 align:middle line:84%
Out here on the wings
there's nitride,

00:28:52.460 --> 00:28:53.890 align:middle line:90%
which is hatched region.

00:28:53.890 --> 00:28:56.170 align:middle line:84%
Underneath the
nitride that's inert.

00:28:56.170 --> 00:28:58.120 align:middle line:90%
That's an inert interface.

00:28:58.120 --> 00:28:59.788 align:middle line:90%
So that's masked.

00:28:59.788 --> 00:29:01.330 align:middle line:84%
Now what they did
was they're looking

00:29:01.330 --> 00:29:04.600 align:middle line:84%
at simulations for case
A and B. And case A

00:29:04.600 --> 00:29:07.510 align:middle line:84%
is when the mask
opening is fairly wide.

00:29:07.510 --> 00:29:10.150 align:middle line:84%
So the mask opening in case
A goes from here to here.

00:29:10.150 --> 00:29:12.520 align:middle line:84%
Case B is you imagine
the opening in the mask

00:29:12.520 --> 00:29:13.460 align:middle line:90%
to be very small.

00:29:13.460 --> 00:29:17.820 align:middle line:84%
So the region that's being
oxidized is much narrower.

00:29:17.820 --> 00:29:22.350 align:middle line:84%
And they did the simulations
for the two cases, A and B.

00:29:22.350 --> 00:29:25.890 align:middle line:84%
So A is the case, these two
curves for a wide opening,

00:29:25.890 --> 00:29:27.180 align:middle line:90%
and B is for a narrow opening.

00:29:27.180 --> 00:29:29.550 align:middle line:84%
But there are two different
types of curves here.

00:29:29.550 --> 00:29:32.070 align:middle line:84%
There's the solid
and the dashed.

00:29:32.070 --> 00:29:37.200 align:middle line:84%
In the solid curve, what they
assumed in their simulations is

00:29:37.200 --> 00:29:40.080 align:middle line:84%
that they assumed the case of
S value or the point defects

00:29:40.080 --> 00:29:43.530 align:middle line:84%
were recombining more slowly
at the inert interface compared

00:29:43.530 --> 00:29:44.910 align:middle line:90%
to the oxidizing interface.

00:29:44.910 --> 00:29:47.670 align:middle line:84%
So they're saying there's
not that much recombination

00:29:47.670 --> 00:29:52.320 align:middle line:84%
over here at the inert interface
compared to the oxidizing.

00:29:52.320 --> 00:29:55.800 align:middle line:84%
When they do that, when
they adjust those surface

00:29:55.800 --> 00:29:58.170 align:middle line:84%
recombination velocities
in that way, what they see

00:29:58.170 --> 00:30:01.020 align:middle line:84%
is when you change the stripe
width from narrow to wide,

00:30:01.020 --> 00:30:04.980 align:middle line:84%
the opening, you get profiles
that look like the solid lines

00:30:04.980 --> 00:30:07.920 align:middle line:84%
where at the very
center of the stripe,

00:30:07.920 --> 00:30:13.300 align:middle line:84%
the junction depths are almost
the same, which is the case,

00:30:13.300 --> 00:30:19.608 align:middle line:84%
if we go back, just go
one slide back to slide 7,

00:30:19.608 --> 00:30:21.900 align:middle line:84%
it almost looks like this
phosphorus case in oxidation.

00:30:21.900 --> 00:30:24.720 align:middle line:84%
The junction depths, regardless
of the width of the opening,

00:30:24.720 --> 00:30:25.750 align:middle line:90%
were about the same.

00:30:25.750 --> 00:30:29.380 align:middle line:84%
And so you can actually
fit this shape,

00:30:29.380 --> 00:30:32.010 align:middle line:84%
this shape right here, to the
experimentally measured shape

00:30:32.010 --> 00:30:34.710 align:middle line:84%
by changing the ratio of the
surface recombination velocity

00:30:34.710 --> 00:30:37.660 align:middle line:84%
at this oxidizing
interface to in inert.

00:30:37.660 --> 00:30:40.350 align:middle line:84%
In the dashed lines,
what did they assume?

00:30:40.350 --> 00:30:43.380 align:middle line:84%
Well, the dashed
lines show the case

00:30:43.380 --> 00:30:45.960 align:middle line:84%
where the surface recombination
velocity of interstitials

00:30:45.960 --> 00:30:47.940 align:middle line:84%
at this oxidizing
interface is about

00:30:47.940 --> 00:30:49.380 align:middle line:90%
the same as the non-oxidizing.

00:30:49.380 --> 00:30:50.920 align:middle line:90%
So they made them equally.

00:30:50.920 --> 00:30:54.780 align:middle line:84%
So if it recombines
equally in this interface

00:30:54.780 --> 00:30:57.720 align:middle line:84%
versus that interface-- in fact,
what you see for a narrow stripe

00:30:57.720 --> 00:31:02.160 align:middle line:84%
is that the overall
junction depth is much lower

00:31:02.160 --> 00:31:03.420 align:middle line:90%
than it is for a wide stripe.

00:31:03.420 --> 00:31:05.560 align:middle line:90%
So the enhancement is much less.

00:31:05.560 --> 00:31:08.160 align:middle line:84%
So actually, people
use the shapes

00:31:08.160 --> 00:31:11.700 align:middle line:84%
of these junctions as a
function of stripe width

00:31:11.700 --> 00:31:14.520 align:middle line:84%
to say something to infer
about the recombination

00:31:14.520 --> 00:31:18.750 align:middle line:84%
velocities at this interface
versus at the inert interface,

00:31:18.750 --> 00:31:20.560 align:middle line:90%
just by changing the duty cycle.

00:31:20.560 --> 00:31:22.152 align:middle line:84%
So this is how, in
SUPREM IV, if you

00:31:22.152 --> 00:31:23.610 align:middle line:84%
look at some of
those coefficients,

00:31:23.610 --> 00:31:25.277 align:middle line:84%
this is how they were
actually measured.

00:31:25.277 --> 00:31:28.040 align:middle line:84%
It's kind of a
clever experiment.

00:31:28.040 --> 00:31:31.250 align:middle line:84%
Slide 9 is actually showing you
some experimental data, again,

00:31:31.250 --> 00:31:34.862 align:middle line:84%
just to give you a feel maybe
from a different vantage point.

00:31:34.862 --> 00:31:36.320 align:middle line:84%
It's a little bit
hard to see this.

00:31:36.320 --> 00:31:39.380 align:middle line:84%
But this is a photograph
from a microscope.

00:31:39.380 --> 00:31:41.900 align:middle line:84%
And you got to get
used to seeing this.

00:31:41.900 --> 00:31:43.220 align:middle line:90%
It's been beveled and stained.

00:31:43.220 --> 00:31:45.770 align:middle line:84%
So this surface up here
that you're looking at

00:31:45.770 --> 00:31:48.380 align:middle line:90%
is the top surface of the chip.

00:31:48.380 --> 00:31:50.400 align:middle line:84%
This surface down
here is the bevel.

00:31:50.400 --> 00:31:53.420 align:middle line:84%
So if, actually, I could
find a piece of chalk--

00:31:53.420 --> 00:31:56.000 align:middle line:84%
there happens to be one
here, which is kind of rare.

00:31:56.000 --> 00:31:59.210 align:middle line:84%
So what they do is,
this is the top surface.

00:31:59.210 --> 00:32:00.860 align:middle line:84%
This region here
has been beveled

00:32:00.860 --> 00:32:04.530 align:middle line:90%
at some very shallow angle.

00:32:04.530 --> 00:32:10.192 align:middle line:84%
And so the top surface
here has the stripes on it.

00:32:10.192 --> 00:32:12.400 align:middle line:84%
So in the microscope, if
you look at the top surface,

00:32:12.400 --> 00:32:13.460 align:middle line:90%
it looks like this.

00:32:13.460 --> 00:32:16.450 align:middle line:84%
So these are the
regions here where

00:32:16.450 --> 00:32:19.070 align:middle line:84%
the oxidation-enhanced
diffusion took place.

00:32:19.070 --> 00:32:22.210 align:middle line:84%
Here's a 50-micron opening,
25, 20, 10, all the way

00:32:22.210 --> 00:32:23.860 align:middle line:90%
down to 4-micron opening.

00:32:23.860 --> 00:32:26.200 align:middle line:84%
This phosphorus, this
region, it turns out

00:32:26.200 --> 00:32:31.000 align:middle line:84%
you can chemically etch the
silicon surface, and it stains.

00:32:31.000 --> 00:32:33.860 align:middle line:84%
So you get a different surface
appearance under the microscope

00:32:33.860 --> 00:32:35.050 align:middle line:90%
where it's N type.

00:32:35.050 --> 00:32:35.852 align:middle line:90%
And so you use.

00:32:35.852 --> 00:32:37.810 align:middle line:84%
This is a really
old-fashioned way of doing it.

00:32:37.810 --> 00:32:39.760 align:middle line:84%
But beveling and
staining the silicon

00:32:39.760 --> 00:32:42.190 align:middle line:84%
was a way to measure the
junction depth because you could

00:32:42.190 --> 00:32:44.260 align:middle line:84%
actually measure it--
basically by doing this

00:32:44.260 --> 00:32:46.900 align:middle line:84%
at a shallow enough angle,
you can spread this out

00:32:46.900 --> 00:32:48.850 align:middle line:84%
over a long distance,
a distance such

00:32:48.850 --> 00:32:52.670 align:middle line:84%
that you can see it in
an optical microscope.

00:32:52.670 --> 00:32:55.930 align:middle line:84%
So this was just to give you
an idea of what the junction

00:32:55.930 --> 00:32:57.010 align:middle line:90%
actually looks like.

00:32:57.010 --> 00:32:59.500 align:middle line:84%
Under a wide opening,
looks like this.

00:32:59.500 --> 00:33:01.180 align:middle line:84%
Under a narrow
opening at 4 microns,

00:33:01.180 --> 00:33:04.230 align:middle line:90%
it's about the same depth.

00:33:04.230 --> 00:33:07.050 align:middle line:84%
So this was
experimental evidence

00:33:07.050 --> 00:33:10.290 align:middle line:84%
that people used and then
fit the SUPREM profiles.

00:33:10.290 --> 00:33:12.420 align:middle line:84%
We go back one shape,
they fit to that shape.

00:33:12.420 --> 00:33:14.128 align:middle line:84%
And they found that
the model looked more

00:33:14.128 --> 00:33:15.250 align:middle line:90%
like the solid line model.

00:33:15.250 --> 00:33:17.700 align:middle line:84%
So they could actually fit
the recombination coefficients

00:33:17.700 --> 00:33:19.613 align:middle line:90%
based on some of this data.

00:33:19.613 --> 00:33:21.780 align:middle line:84%
So it was a relatively--
it was a clever experiment,

00:33:21.780 --> 00:33:23.760 align:middle line:90%
relatively simple techniques--

00:33:23.760 --> 00:33:27.750 align:middle line:84%
oxidizing, patterning,
and beveling and staining

00:33:27.750 --> 00:33:31.170 align:middle line:84%
were used in some of these
original experiments,

00:33:31.170 --> 00:33:34.230 align:middle line:90%
then at high temperatures.

00:33:34.230 --> 00:33:35.670 align:middle line:84%
OK, so that's to
give you an idea

00:33:35.670 --> 00:33:39.482 align:middle line:84%
of how some of these experiments
were done originally.

00:33:39.482 --> 00:33:40.440 align:middle line:90%
Now, let's talk about--

00:33:40.440 --> 00:33:42.240 align:middle line:84%
I want to talk about
a specific example

00:33:42.240 --> 00:33:44.340 align:middle line:84%
that we kind of whizzed
through last time

00:33:44.340 --> 00:33:47.340 align:middle line:84%
when we were doing towards
the end of the class notes.

00:33:47.340 --> 00:33:49.920 align:middle line:84%
Let's talk about
boron diffusion.

00:33:49.920 --> 00:33:52.950 align:middle line:84%
And we're going to say
that boron diffuses based

00:33:52.950 --> 00:33:56.370 align:middle line:84%
on all the data that people have
with only two point defects.

00:33:56.370 --> 00:33:58.990 align:middle line:84%
Of all the point defects
it could have as pairs,

00:33:58.990 --> 00:34:01.050 align:middle line:84%
these are the two
that it prefers.

00:34:01.050 --> 00:34:04.560 align:middle line:84%
It prefers a neutrally
charged interstitial,

00:34:04.560 --> 00:34:07.170 align:middle line:84%
silicon interstitial,
which we write as I0.

00:34:07.170 --> 00:34:08.710 align:middle line:90%
And it pairs with that.

00:34:08.710 --> 00:34:10.800 align:middle line:84%
And so we have a
B, a boron minus.

00:34:10.800 --> 00:34:15.639 align:middle line:84%
Again, that boron substitutional
in the lattice is an acceptor.

00:34:15.639 --> 00:34:17.643 align:middle line:84%
So it has a net
negative charge when

00:34:17.643 --> 00:34:18.810 align:middle line:90%
it's substitutional lattice.

00:34:18.810 --> 00:34:21.150 align:middle line:84%
It combines with a
neutral interstitial

00:34:21.150 --> 00:34:25.409 align:middle line:84%
and forms a pair,
DI super minus.

00:34:25.409 --> 00:34:28.050 align:middle line:84%
Minus because the net charge
on that pair, if you were

00:34:28.050 --> 00:34:32.530 align:middle line:84%
consider it as a pair, is one
negative net electron charge.

00:34:32.530 --> 00:34:33.850 align:middle line:90%
So it likes to do that.

00:34:33.850 --> 00:34:38.650 align:middle line:84%
Or boron might like to pair
with a positively charged

00:34:38.650 --> 00:34:44.290 align:middle line:84%
interstitial, particularly
because the concentration

00:34:44.290 --> 00:34:46.270 align:middle line:84%
of these interstitials
tends to go up

00:34:46.270 --> 00:34:47.739 align:middle line:90%
in high doping concentrations.

00:34:47.739 --> 00:34:49.060 align:middle line:84%
But even in low
doping concentrations,

00:34:49.060 --> 00:34:51.643 align:middle line:84%
you can see there might be some
kind of coulombic interaction.

00:34:51.643 --> 00:34:56.170 align:middle line:84%
A boron minus might pair with a
positively charged interstitial

00:34:56.170 --> 00:34:57.730 align:middle line:90%
and form a BI pair.

00:34:57.730 --> 00:34:59.890 align:middle line:84%
The pair charge of
this particular pair

00:34:59.890 --> 00:35:02.750 align:middle line:84%
now is actually
neutral as a pair.

00:35:02.750 --> 00:35:05.740 align:middle line:84%
So we have two of these
simple chemical reactions.

00:35:05.740 --> 00:35:08.623 align:middle line:84%
And they give rise to
fluxes of mobile species.

00:35:08.623 --> 00:35:10.540 align:middle line:84%
So remember originally,
on the left-hand side,

00:35:10.540 --> 00:35:11.590 align:middle line:90%
the boron is immobile.

00:35:11.590 --> 00:35:14.380 align:middle line:84%
One of these guys comes
along, pairs with it.

00:35:14.380 --> 00:35:17.200 align:middle line:84%
Now it's mobile on
the right-hand side.

00:35:17.200 --> 00:35:20.270 align:middle line:84%
And we sum these two,
the flux of these two.

00:35:20.270 --> 00:35:24.010 align:middle line:84%
And we say the total flux
of boron in the sample

00:35:24.010 --> 00:35:28.180 align:middle line:84%
is going to be the flux of
the BI minus pair and the BI

00:35:28.180 --> 00:35:31.420 align:middle line:90%
neutral, uncharged, pair.

00:35:31.420 --> 00:35:36.190 align:middle line:84%
So that's an example
of how SUPREM

00:35:36.190 --> 00:35:38.920 align:middle line:84%
might consider this, at least
from a chemical equation

00:35:38.920 --> 00:35:40.800 align:middle line:90%
point of view.

00:35:40.800 --> 00:35:43.430 align:middle line:84%
So given that, those
simple two equations,

00:35:43.430 --> 00:35:46.528 align:middle line:84%
and all that we know about
deviations from Fick's law--

00:35:46.528 --> 00:35:48.070 align:middle line:84%
I showed this last
time, but again, I

00:35:48.070 --> 00:35:52.700 align:middle line:84%
think we went through it a
little too quickly on slide 11.

00:35:52.700 --> 00:35:56.870 align:middle line:84%
I just want to show, again, the
overall equation that SUPREM IV

00:35:56.870 --> 00:36:01.850 align:middle line:84%
is solving for boron, assuming
it's diffusing with just two

00:36:01.850 --> 00:36:03.757 align:middle line:84%
species with neutral
interstitials

00:36:03.757 --> 00:36:05.090 align:middle line:90%
and with positive interstitials.

00:36:05.090 --> 00:36:10.650 align:middle line:84%
This is the actual flux,
so-called diffusion equation,

00:36:10.650 --> 00:36:13.600 align:middle line:90%
that SUPREM is solving.

00:36:13.600 --> 00:36:17.490 align:middle line:84%
And it's a far cry from what you
would think in a simple case.

00:36:17.490 --> 00:36:20.040 align:middle line:84%
You would think it
would just be DC boron,

00:36:20.040 --> 00:36:24.780 align:middle line:84%
or partial T, if you want,
is equal to a diffusivity

00:36:24.780 --> 00:36:31.080 align:middle line:84%
times partial concentration
of boron with respect to X.

00:36:31.080 --> 00:36:32.427 align:middle line:90%
This is what you might think.

00:36:32.427 --> 00:36:34.260 align:middle line:84%
That's the simple version
of boron diffusion

00:36:34.260 --> 00:36:35.940 align:middle line:90%
when we started this chapter 7.

00:36:35.940 --> 00:36:39.090 align:middle line:84%
It's just regular old
Gaussian type diffusion.

00:36:39.090 --> 00:36:40.740 align:middle line:84%
That equation
looks pretty simple

00:36:40.740 --> 00:36:43.950 align:middle line:84%
compared to that
one up on slide 11.

00:36:43.950 --> 00:36:47.950 align:middle line:84%
And this is actually
what SUPREM is solving.

00:36:47.950 --> 00:36:50.198 align:middle line:84%
So where do all these
terms come from?

00:36:50.198 --> 00:36:51.990 align:middle line:84%
Rather than deriving
it, let's just sort of

00:36:51.990 --> 00:36:53.760 align:middle line:84%
examine and see if
we can understand

00:36:53.760 --> 00:36:55.230 align:middle line:84%
based on what
we've talked about,

00:36:55.230 --> 00:36:57.270 align:middle line:84%
what the different
effects are that are

00:36:57.270 --> 00:37:01.950 align:middle line:84%
causing it to have this large
term here in curly brackets.

00:37:01.950 --> 00:37:03.720 align:middle line:84%
Well, the first
thing you can notice

00:37:03.720 --> 00:37:08.650 align:middle line:84%
is the concentration of
boron with respect to time

00:37:08.650 --> 00:37:12.240 align:middle line:90%
is the D by DX of a flux.

00:37:12.240 --> 00:37:13.420 align:middle line:90%
That does hold.

00:37:13.420 --> 00:37:16.870 align:middle line:84%
Everything in curly brackets
here is represented by a flux.

00:37:16.870 --> 00:37:19.520 align:middle line:84%
The question is, why does
the flux look so complicated?

00:37:19.520 --> 00:37:21.290 align:middle line:84%
Well, the first
part of the flux,

00:37:21.290 --> 00:37:26.480 align:middle line:84%
there's a term that
depends on DBI star.

00:37:26.480 --> 00:37:28.336 align:middle line:90%
So what is that?

00:37:28.336 --> 00:37:33.130 align:middle line:84%
That is inert, low-concentration
diffusion of boron

00:37:33.130 --> 00:37:35.710 align:middle line:84%
that's driven by the
boron gradient itself.

00:37:35.710 --> 00:37:38.150 align:middle line:84%
So that would be equivalent
to this D up here.

00:37:38.150 --> 00:37:44.770 align:middle line:84%
So that's sort of the
simplest part of the equation.

00:37:44.770 --> 00:37:47.620 align:middle line:84%
But multiplying
DBI star, there is

00:37:47.620 --> 00:37:50.590 align:middle line:84%
this interstitial
supersaturation coefficient.

00:37:50.590 --> 00:37:55.160 align:middle line:84%
CI over CI star
appears right here.

00:37:55.160 --> 00:37:58.660 align:middle line:84%
And again, that's because we're
trying to take into account here

00:37:58.660 --> 00:38:00.320 align:middle line:90%
these non-equilibrium effects.

00:38:00.320 --> 00:38:02.380 align:middle line:84%
This was sort of an
equilibrium diffusion,

00:38:02.380 --> 00:38:05.470 align:middle line:84%
but of excess silicon
interstitials,

00:38:05.470 --> 00:38:07.550 align:middle line:90%
and that we have pair diffusion.

00:38:07.550 --> 00:38:11.920 align:middle line:90%
So there's CI over CI star here.

00:38:11.920 --> 00:38:17.600 align:middle line:84%
And it's gradient
is in here, as well.

00:38:17.600 --> 00:38:19.960 align:middle line:84%
There are high
concentration effects

00:38:19.960 --> 00:38:21.050 align:middle line:90%
on the dopant diffusivity.

00:38:21.050 --> 00:38:24.280 align:middle line:84%
So this you recognize
this thing in parentheses,

00:38:24.280 --> 00:38:27.550 align:middle line:84%
it's 1 plus beta P over
NI divided by 1 plus beta.

00:38:27.550 --> 00:38:29.920 align:middle line:84%
That whole thing is
Fermi-level effect.

00:38:29.920 --> 00:38:31.480 align:middle line:84%
That's the high
concentration effect.

00:38:31.480 --> 00:38:34.390 align:middle line:84%
Remember, beta was the
ratio of boron diffusing

00:38:34.390 --> 00:38:38.380 align:middle line:84%
with the I star divided
by the ratio diffusing

00:38:38.380 --> 00:38:40.810 align:middle line:90%
of neutral interstitials.

00:38:40.810 --> 00:38:44.530 align:middle line:84%
And so as this kicks in,
as P over NI gets large,

00:38:44.530 --> 00:38:46.690 align:middle line:84%
it's going to bump
up the diffusivity,

00:38:46.690 --> 00:38:49.040 align:middle line:90%
the effect of diffusivity.

00:38:49.040 --> 00:38:50.920 align:middle line:84%
So if you want, you can
think of all these--

00:38:50.920 --> 00:38:53.770 align:middle line:84%
there's a lot of these things
here upfront, these three terms,

00:38:53.770 --> 00:38:56.320 align:middle line:84%
as all multiplying
the inner diffusivity

00:38:56.320 --> 00:38:58.930 align:middle line:84%
by some number that's going to
pump it up, or maybe pump it

00:38:58.930 --> 00:39:01.510 align:middle line:84%
down if the CI over
Ci star goes down

00:39:01.510 --> 00:39:03.070 align:middle line:90%
under injection of vacancies.

00:39:03.070 --> 00:39:05.740 align:middle line:84%
And this last bit
here, this partial

00:39:05.740 --> 00:39:08.350 align:middle line:84%
x of the lin of
everything in parentheses,

00:39:08.350 --> 00:39:12.220 align:middle line:84%
that came-- you covered last
week when Maggie was lecturing.

00:39:12.220 --> 00:39:15.370 align:middle line:84%
That's the electric field
effect, just the fact

00:39:15.370 --> 00:39:20.980 align:middle line:84%
that besides just the gradient
of the concentration gradient

00:39:20.980 --> 00:39:22.300 align:middle line:90%
that drives diffusion.

00:39:22.300 --> 00:39:24.070 align:middle line:90%
We also know electric fields.

00:39:24.070 --> 00:39:26.780 align:middle line:90%
We can have a field-aided term.

00:39:26.780 --> 00:39:29.143 align:middle line:84%
So that's where this
last term is coming from.

00:39:29.143 --> 00:39:31.810 align:middle line:84%
So you can get a feel for where
all these terms are coming from.

00:39:31.810 --> 00:39:34.343 align:middle line:84%
It's a fairly-- you can't
imagine doing this by hand.

00:39:34.343 --> 00:39:36.010 align:middle line:84%
To solve this equation,
obviously you're

00:39:36.010 --> 00:39:38.343 align:middle line:84%
going to have to do something
on the computer, something

00:39:38.343 --> 00:39:40.930 align:middle line:90%
numerically.

00:39:40.930 --> 00:39:42.830 align:middle line:90%
OK, so let's go to slide--

00:39:42.830 --> 00:39:46.990 align:middle line:84%
so that kind of gives you an
example of the boron case.

00:39:46.990 --> 00:39:49.990 align:middle line:84%
Now I want to give you an
example of the case which

00:39:49.990 --> 00:39:53.260 align:middle line:84%
is a little bit strange,
puzzled people for a long time,

00:39:53.260 --> 00:39:55.450 align:middle line:84%
but now is understood
as an example

00:39:55.450 --> 00:39:59.380 align:middle line:84%
of the impact of the
gradient in the point defect.

00:39:59.380 --> 00:40:02.620 align:middle line:84%
Not the gradient in
the dopant itself,

00:40:02.620 --> 00:40:04.780 align:middle line:84%
but a gradient in
injected point defects.

00:40:04.780 --> 00:40:08.290 align:middle line:84%
How are they going to change
the device dopant profiles?

00:40:08.290 --> 00:40:11.020 align:middle line:84%
And we're going to talk about
this in much more detail

00:40:11.020 --> 00:40:12.640 align:middle line:84%
once I talk about
ion implant damage.

00:40:12.640 --> 00:40:15.040 align:middle line:84%
But just want to
introduce it at this point

00:40:15.040 --> 00:40:18.610 align:middle line:84%
to make the point that the
gradient in the point defects

00:40:18.610 --> 00:40:20.470 align:middle line:90%
can drive diffusion, as well.

00:40:20.470 --> 00:40:22.720 align:middle line:84%
There is something called
the reverse short channel

00:40:22.720 --> 00:40:26.230 align:middle line:84%
effect that puzzled people for
quite a bit in the early 90s

00:40:26.230 --> 00:40:28.960 align:middle line:84%
and ended up being explained,
this electrical effect

00:40:28.960 --> 00:40:33.670 align:middle line:84%
in devices being explained by
this boron pair diffusion, boron

00:40:33.670 --> 00:40:34.970 align:middle line:90%
interstitial pair diffusion.

00:40:34.970 --> 00:40:37.270 align:middle line:84%
So before we talk about reverse
short channel effect, which

00:40:37.270 --> 00:40:38.812 align:middle line:84%
sounds really weird,
how about what's

00:40:38.812 --> 00:40:41.680 align:middle line:84%
the regular or the usual
short channel effect?

00:40:41.680 --> 00:40:45.220 align:middle line:84%
We talked about it a little
bit several lectures ago.

00:40:45.220 --> 00:40:49.030 align:middle line:84%
But basically, the usual
short channel effect

00:40:49.030 --> 00:40:51.580 align:middle line:84%
is for a given process,
the threshold voltage

00:40:51.580 --> 00:40:55.630 align:middle line:84%
goes down as you decrease the L.
So for a given process on chip,

00:40:55.630 --> 00:40:58.880 align:middle line:84%
as you look at smaller and
smaller devices made on chip

00:40:58.880 --> 00:41:01.430 align:middle line:84%
and you plot the threshold
voltage, what you'll see

00:41:01.430 --> 00:41:03.200 align:middle line:90%
is it rolls off.

00:41:03.200 --> 00:41:04.730 align:middle line:90%
Generally the VT goes down.

00:41:04.730 --> 00:41:06.500 align:middle line:84%
It becomes easier to
turn on the device.

00:41:06.500 --> 00:41:08.780 align:middle line:84%
And here's a
textbook if you want

00:41:08.780 --> 00:41:11.360 align:middle line:84%
to go through in understanding
some of the physics.

00:41:11.360 --> 00:41:15.470 align:middle line:84%
But basically, what happens
is as you bring the source

00:41:15.470 --> 00:41:19.280 align:middle line:84%
and drain closer, the
potential due to the drain

00:41:19.280 --> 00:41:22.490 align:middle line:84%
actually starts interacting with
the potential in the channel,

00:41:22.490 --> 00:41:25.400 align:middle line:90%
and it starts having an effect.

00:41:25.400 --> 00:41:28.130 align:middle line:84%
Ordinarily you'd like
that not to be the case.

00:41:28.130 --> 00:41:30.990 align:middle line:84%
You'd like to have just the
gate have the only effect.

00:41:30.990 --> 00:41:34.700 align:middle line:84%
So the lowering of the potential
barrier by the drain voltage

00:41:34.700 --> 00:41:42.050 align:middle line:84%
is what causes this to go
down as you shrink the channel

00:41:42.050 --> 00:41:43.220 align:middle line:90%
length.

00:41:43.220 --> 00:41:47.630 align:middle line:84%
And how much that potential
barrier can be up raised

00:41:47.630 --> 00:41:51.020 align:middle line:84%
or lowered is a strong function
of the profile of the boron,

00:41:51.020 --> 00:41:54.830 align:middle line:84%
say in an NFET,
underneath the channel.

00:41:54.830 --> 00:41:56.920 align:middle line:84%
So in fact, if we
go to slide 13--

00:41:56.920 --> 00:41:59.980 align:middle line:84%
just, again, I took this
from Tower and Ning's book

00:41:59.980 --> 00:42:03.272 align:middle line:84%
on fundamentals of modern
devices for the device physics.

00:42:03.272 --> 00:42:05.230 align:middle line:84%
Again, you don't have to
understand the detail,

00:42:05.230 --> 00:42:07.600 align:middle line:84%
but just gives you an idea
of where this comes from.

00:42:07.600 --> 00:42:10.300 align:middle line:84%
Imagine here I have--
this is my source, my gate

00:42:10.300 --> 00:42:12.370 align:middle line:84%
up here, and the drain
over on the right.

00:42:12.370 --> 00:42:16.300 align:middle line:84%
And this distance, 0, is right
at the source injection point.

00:42:16.300 --> 00:42:17.960 align:middle line:90%
And L is the channel length.

00:42:17.960 --> 00:42:19.360 align:middle line:90%
So that's right at the drain.

00:42:19.360 --> 00:42:21.430 align:middle line:84%
And what he's plotted
here in this book

00:42:21.430 --> 00:42:22.940 align:middle line:90%
is the surface potential.

00:42:22.940 --> 00:42:25.690 align:middle line:84%
So that's the potential
at the surface

00:42:25.690 --> 00:42:29.740 align:middle line:84%
that a carrier would experience
as a function of distance

00:42:29.740 --> 00:42:30.920 align:middle line:90%
along the channel.

00:42:30.920 --> 00:42:33.280 align:middle line:84%
So here at 0, you're just
starting in the source.

00:42:33.280 --> 00:42:34.930 align:middle line:84%
And it looks
something like this.

00:42:34.930 --> 00:42:37.930 align:middle line:84%
Curve A is for the case
of a 6-micron device.

00:42:37.930 --> 00:42:42.860 align:middle line:84%
Curve B is a 1.25
at, say, half a volt.

00:42:42.860 --> 00:42:49.510 align:middle line:84%
And curve C, when I put a drain
bias of 5 volts, what happens?

00:42:49.510 --> 00:42:52.573 align:middle line:84%
Actually, the potential, even
in the center of the channel,

00:42:52.573 --> 00:42:54.740 align:middle line:84%
instead of just being the
potential of being lowered

00:42:54.740 --> 00:42:56.407 align:middle line:84%
in the drain, it's
actually because it's

00:42:56.407 --> 00:42:59.820 align:middle line:84%
a short channel the potential
is actually lowered here.

00:42:59.820 --> 00:43:03.350 align:middle line:84%
And so it's that ability of the
drain voltage to impact things

00:43:03.350 --> 00:43:06.830 align:middle line:84%
that is a short-channel
effect, and is partly

00:43:06.830 --> 00:43:09.800 align:middle line:84%
responsible for the
lowering of the VT.

00:43:09.800 --> 00:43:12.110 align:middle line:84%
So the way people-- when
you scale devices shorter,

00:43:12.110 --> 00:43:15.200 align:middle line:84%
the way people counteract
this is they dope

00:43:15.200 --> 00:43:16.370 align:middle line:90%
underneath the channel.

00:43:16.370 --> 00:43:17.818 align:middle line:84%
They counter-dope
it more heavily

00:43:17.818 --> 00:43:18.860 align:middle line:90%
with the opposite dopant.

00:43:18.860 --> 00:43:22.737 align:middle line:84%
So they add more
boron, for example.

00:43:22.737 --> 00:43:24.320 align:middle line:84%
If you were to add
more boron, there'd

00:43:24.320 --> 00:43:28.490 align:middle line:84%
be much less of this effect
of this potential being

00:43:28.490 --> 00:43:30.300 align:middle line:90%
impacted by the drain.

00:43:30.300 --> 00:43:32.240 align:middle line:84%
So there's a
tendency, as you scale

00:43:32.240 --> 00:43:33.740 align:middle line:84%
devices smaller
and smaller, you'll

00:43:33.740 --> 00:43:34.990 align:middle line:90%
see the doping in the channel.

00:43:34.990 --> 00:43:38.570 align:middle line:84%
If you go on the ITR roadmap,
every year it goes up.

00:43:38.570 --> 00:43:41.030 align:middle line:84%
mid 10 to the 17th, 20 to
the 18th, mid 10 to the 18th

00:43:41.030 --> 00:43:43.080 align:middle line:90%
as we shrink devices.

00:43:43.080 --> 00:43:44.930 align:middle line:84%
So people counteract
this short channel,

00:43:44.930 --> 00:43:48.240 align:middle line:84%
the normal short channel
effect, by upping the doping

00:43:48.240 --> 00:43:48.945 align:middle line:90%
in the channel.

00:43:48.945 --> 00:43:52.060 align:middle line:90%


00:43:52.060 --> 00:43:54.360 align:middle line:84%
But what people saw was
the reverse short channel

00:43:54.360 --> 00:43:56.370 align:middle line:84%
effect, which was
confusing people,

00:43:56.370 --> 00:44:00.270 align:middle line:84%
is that for short channel
lengths on the chip,

00:44:00.270 --> 00:44:03.360 align:middle line:84%
it was actually found that
the threshold voltage actually

00:44:03.360 --> 00:44:06.420 align:middle line:84%
increased in a certain
range of channel length.

00:44:06.420 --> 00:44:09.000 align:middle line:84%
So as they shrunk the channel
length in a certain range,

00:44:09.000 --> 00:44:12.600 align:middle line:84%
VT actually went up, almost as
if the doping in the channel

00:44:12.600 --> 00:44:14.800 align:middle line:84%
was getting higher
in that range.

00:44:14.800 --> 00:44:16.440 align:middle line:84%
So all these devices
are fabricated

00:44:16.440 --> 00:44:19.410 align:middle line:84%
on the same chip, subject
to the same temperatures

00:44:19.410 --> 00:44:22.710 align:middle line:84%
on the same wafer, same
iron implants, everything.

00:44:22.710 --> 00:44:24.870 align:middle line:84%
Why would it be the
doping would be different

00:44:24.870 --> 00:44:27.750 align:middle line:84%
in the center of the channel,
depending on the channel length?

00:44:27.750 --> 00:44:31.330 align:middle line:84%
And people were mystified
by this for a while.

00:44:31.330 --> 00:44:33.955 align:middle line:84%
So the reverse short
channel effect basically

00:44:33.955 --> 00:44:35.080 align:middle line:90%
looked something like this.

00:44:35.080 --> 00:44:37.150 align:middle line:84%
And this is kind of
a backwards plot.

00:44:37.150 --> 00:44:39.750 align:middle line:84%
But if you plot
threshold voltage--

00:44:39.750 --> 00:44:41.580 align:middle line:90%
now this is on the right axis.

00:44:41.580 --> 00:44:43.720 align:middle line:84%
Inverse channel length
is increasing this way.

00:44:43.720 --> 00:44:46.590 align:middle line:84%
But if you want to look at the
upper X-axis, it's helpful.

00:44:46.590 --> 00:44:48.840 align:middle line:84%
The channel length
is here on the right

00:44:48.840 --> 00:44:51.700 align:middle line:84%
going from 0.2 all the
way up to 1 micron.

00:44:51.700 --> 00:44:53.710 align:middle line:84%
Or if you're
shrinking the device,

00:44:53.710 --> 00:44:56.270 align:middle line:90%
you're going from here to here.

00:44:56.270 --> 00:45:00.400 align:middle line:84%
So as I'm shrinking down here
from, say, a 10-micron device

00:45:00.400 --> 00:45:02.980 align:middle line:84%
down to 1 micron, what
was actually happening

00:45:02.980 --> 00:45:04.840 align:middle line:90%
from 10 to 1 micron?

00:45:04.840 --> 00:45:07.960 align:middle line:84%
Actually, it's easier to see
it if you look at the closed

00:45:07.960 --> 00:45:09.130 align:middle line:90%
squares from the experiment.

00:45:09.130 --> 00:45:13.930 align:middle line:84%
The VT was actually going
up from about 1.1 volts

00:45:13.930 --> 00:45:18.260 align:middle line:84%
up to 1.2 or 1.25 volts, which
is a significant increase.

00:45:18.260 --> 00:45:22.270 align:middle line:84%
So you're shrinking
devices from 10 microns

00:45:22.270 --> 00:45:24.580 align:middle line:84%
or 5 microns down to
the third of a micron.

00:45:24.580 --> 00:45:25.500 align:middle line:90%
VT is going up.

00:45:25.500 --> 00:45:27.700 align:middle line:84%
That's the opposite of
what everyone expected

00:45:27.700 --> 00:45:30.350 align:middle line:84%
from the old days from the
regular short channel effect.

00:45:30.350 --> 00:45:34.600 align:middle line:84%
So people call this the
reverse short channel effect.

00:45:34.600 --> 00:45:37.510 align:middle line:84%
And in fact, people were
able to-- it turns out

00:45:37.510 --> 00:45:40.270 align:middle line:84%
there's a paper in 1993
at IEDM from Rafferty.

00:45:40.270 --> 00:45:42.130 align:middle line:84%
They were actually
able to explain this

00:45:42.130 --> 00:45:46.450 align:middle line:84%
based on simulating what they
thought the boron profile would

00:45:46.450 --> 00:45:49.112 align:middle line:84%
be in this nMOSFET in
a case where there was

00:45:49.112 --> 00:45:50.320 align:middle line:90%
transient enhanced diffusion.

00:45:50.320 --> 00:45:52.060 align:middle line:84%
And we haven't yet
talked about TED.

00:45:52.060 --> 00:45:56.200 align:middle line:84%
But basically, what they found
was that the source drain

00:45:56.200 --> 00:45:58.360 align:middle line:84%
implants were injecting
excess interstitials

00:45:58.360 --> 00:46:01.090 align:middle line:84%
and setting up fluxes of
interstitials that were then

00:46:01.090 --> 00:46:03.670 align:middle line:84%
driving the boron, which
was originally buried,

00:46:03.670 --> 00:46:05.810 align:middle line:84%
driving it closer
to the surface.

00:46:05.810 --> 00:46:07.960 align:middle line:84%
And if you made the
channel shorter,

00:46:07.960 --> 00:46:10.840 align:middle line:84%
this effect was even
greater, basically,

00:46:10.840 --> 00:46:13.610 align:middle line:84%
because you're bringing in-- the
center of the channel is being

00:46:13.610 --> 00:46:16.490 align:middle line:84%
brought closer as you change the
channel, closer to the source

00:46:16.490 --> 00:46:19.073 align:middle line:84%
drain regions where the excess
interstitials were being pumped

00:46:19.073 --> 00:46:20.690 align:middle line:90%
in.

00:46:20.690 --> 00:46:23.810 align:middle line:84%
But in either case,
whether it's OED or TED,

00:46:23.810 --> 00:46:27.200 align:middle line:84%
the point was that they
were able to explain based

00:46:27.200 --> 00:46:30.470 align:middle line:84%
on these diffusion models that
more boron, more p-type dopant,

00:46:30.470 --> 00:46:33.230 align:middle line:84%
was ending up in the channel
region of a short device,

00:46:33.230 --> 00:46:38.240 align:middle line:84%
say of 0.3 micron device, than
would be in a 1-micron device.

00:46:38.240 --> 00:46:41.540 align:middle line:84%
More boron means instead
of the short channel effect

00:46:41.540 --> 00:46:44.540 align:middle line:84%
and VT rolling off-- actually,
there was so much extra boron

00:46:44.540 --> 00:46:46.790 align:middle line:90%
that VT was going up.

00:46:46.790 --> 00:46:49.550 align:middle line:84%
So the electrical engineers
and the circuit people

00:46:49.550 --> 00:46:52.280 align:middle line:84%
who would see these weird VT
variations with channel length

00:46:52.280 --> 00:46:54.798 align:middle line:84%
and didn't know
about the processing

00:46:54.798 --> 00:46:56.840 align:middle line:84%
were mystified as to how
this could be happening.

00:46:56.840 --> 00:46:58.310 align:middle line:84%
They just assumed, well,
the boron concentration

00:46:58.310 --> 00:47:00.380 align:middle line:84%
is the same on a short
device and a long device.

00:47:00.380 --> 00:47:02.000 align:middle line:90%
Well, actually, it's not.

00:47:02.000 --> 00:47:02.570 align:middle line:90%
It can vary.

00:47:02.570 --> 00:47:05.990 align:middle line:84%
And of course, that means you
need these more complex models

00:47:05.990 --> 00:47:08.240 align:middle line:84%
that haven't taken into
account point defect injection

00:47:08.240 --> 00:47:11.810 align:middle line:84%
from the sides in order to
be able to model the boron

00:47:11.810 --> 00:47:14.990 align:middle line:84%
profile accurately and to
get the device VT right.

00:47:14.990 --> 00:47:17.480 align:middle line:84%
So that's sort of
a classic example

00:47:17.480 --> 00:47:22.610 align:middle line:84%
of how these complex models
impact device performance.

00:47:22.610 --> 00:47:24.980 align:middle line:84%
And in fact, here's
a cartoon explanation

00:47:24.980 --> 00:47:29.560 align:middle line:90%
on slide 15 where we--

00:47:29.560 --> 00:47:32.650 align:middle line:84%
this is a two-dimensional
SUPREM simulation

00:47:32.650 --> 00:47:35.710 align:middle line:84%
of what's going on in the
reverse short channel effect.

00:47:35.710 --> 00:47:38.830 align:middle line:84%
And what's being shown here
is a relatively short device,

00:47:38.830 --> 00:47:39.850 align:middle line:90%
short channel length.

00:47:39.850 --> 00:47:44.950 align:middle line:84%
And the different colors are the
different contours corresponding

00:47:44.950 --> 00:47:46.730 align:middle line:84%
to constant doping
concentrations.

00:47:46.730 --> 00:47:48.610 align:middle line:84%
And if you just for
a moment imagine,

00:47:48.610 --> 00:47:50.210 align:middle line:84%
this is the drain
over on the right,

00:47:50.210 --> 00:47:54.100 align:middle line:84%
you see this little region
here is the drain extension.

00:47:54.100 --> 00:47:56.480 align:middle line:90%
And down here is the deep drain.

00:47:56.480 --> 00:47:59.890 align:middle line:84%
Here's the source extension and
the deep source extending down

00:47:59.890 --> 00:48:02.500 align:middle line:84%
to about this
blue-colored region.

00:48:02.500 --> 00:48:05.890 align:middle line:84%
These arrows that are emanating
from the source and drain,

00:48:05.890 --> 00:48:09.550 align:middle line:84%
they are interstitial fluxes
coming from the surface

00:48:09.550 --> 00:48:10.660 align:middle line:90%
of the source and drain.

00:48:10.660 --> 00:48:12.250 align:middle line:84%
These interstitials,
people believed

00:48:12.250 --> 00:48:15.192 align:middle line:84%
in this particular model, were
being injected due to the damage

00:48:15.192 --> 00:48:16.150 align:middle line:90%
due to the ion implant.

00:48:16.150 --> 00:48:18.850 align:middle line:84%
And we're going to talk in the
next few lectures about ion

00:48:18.850 --> 00:48:20.230 align:middle line:90%
implantation and how it damages.

00:48:20.230 --> 00:48:22.390 align:middle line:84%
But just take that
with a grain of salt,

00:48:22.390 --> 00:48:25.360 align:middle line:84%
that you believe that there
was a process that introduced

00:48:25.360 --> 00:48:28.040 align:middle line:84%
a lot of excess interstitials
only in these regions,

00:48:28.040 --> 00:48:29.810 align:middle line:90%
not where the gate was.

00:48:29.810 --> 00:48:31.820 align:middle line:84%
So these interstitials
were coming in

00:48:31.820 --> 00:48:33.960 align:middle line:84%
and they were
diffusing all around.

00:48:33.960 --> 00:48:36.230 align:middle line:84%
So these arrows represent
interstitial fluxes.

00:48:36.230 --> 00:48:39.388 align:middle line:84%
And they're recombining
at the various interfaces.

00:48:39.388 --> 00:48:41.930 align:middle line:84%
Now, look at this interstitial
flux here that goes like this.

00:48:41.930 --> 00:48:44.970 align:middle line:84%
This arrow points this direction
and goes up towards the surface.

00:48:44.970 --> 00:48:47.967 align:middle line:84%
So this interstitial
flux, this gradient

00:48:47.967 --> 00:48:50.300 align:middle line:84%
of interstitials where there's
a high concentration here

00:48:50.300 --> 00:48:52.400 align:middle line:90%
and going down at this point.

00:48:52.400 --> 00:48:54.320 align:middle line:84%
That gradient of
interstitials was actually

00:48:54.320 --> 00:48:56.710 align:middle line:90%
dragging the boron with it.

00:48:56.710 --> 00:48:59.450 align:middle line:84%
It was actually dragging
the boron with it

00:48:59.450 --> 00:49:02.690 align:middle line:84%
and moving the peak boron
profile from where it originally

00:49:02.690 --> 00:49:04.400 align:middle line:84%
was more deep in the
sample, moving it up

00:49:04.400 --> 00:49:05.430 align:middle line:90%
towards the surface.

00:49:05.430 --> 00:49:07.970 align:middle line:84%
So in a short device,
it was causing the boron

00:49:07.970 --> 00:49:09.810 align:middle line:90%
to be higher at the surface.

00:49:09.810 --> 00:49:12.140 align:middle line:84%
And so this is a
two-dimensional representation.

00:49:12.140 --> 00:49:14.240 align:middle line:84%
If you take a cut straight
through the center,

00:49:14.240 --> 00:49:17.960 align:middle line:84%
right here at x equals 0 and
look along the y direction,

00:49:17.960 --> 00:49:22.250 align:middle line:84%
in the vertical direction, you
can see three different curves

00:49:22.250 --> 00:49:22.830 align:middle line:90%
on this plot.

00:49:22.830 --> 00:49:24.622 align:middle line:84%
So this is a plot right
through the center,

00:49:24.622 --> 00:49:27.120 align:middle line:84%
the concentration of boron
versus depth into the device.

00:49:27.120 --> 00:49:30.340 align:middle line:84%
So 0 would be right at the
surface by the channel.

00:49:30.340 --> 00:49:32.090 align:middle line:84%
And there are three
different curves here.

00:49:32.090 --> 00:49:34.280 align:middle line:90%
The red one is for one micron.

00:49:34.280 --> 00:49:37.880 align:middle line:84%
And you can see it peaks
here at a certain depth.

00:49:37.880 --> 00:49:39.170 align:middle line:90%
1 micron channel length.

00:49:39.170 --> 00:49:42.230 align:middle line:84%
The blue, the dashed blue, is a
quarter micron channel length.

00:49:42.230 --> 00:49:47.090 align:middle line:84%
And the dashed green is
a 0.18, even smaller.

00:49:47.090 --> 00:49:48.800 align:middle line:84%
And indeed, what the
model is predicting,

00:49:48.800 --> 00:49:51.050 align:middle line:84%
as I'm going to shorter
and shorter channels,

00:49:51.050 --> 00:49:52.580 align:middle line:84%
the amount of boron
at the surface

00:49:52.580 --> 00:49:55.310 align:middle line:84%
is going up here by
a factor of almost 3.

00:49:55.310 --> 00:49:56.370 align:middle line:90%
Something like that.

00:49:56.370 --> 00:49:57.420 align:middle line:90%
3 to 4.

00:49:57.420 --> 00:50:00.630 align:middle line:84%
So indeed, if you increase
the boron concentration

00:50:00.630 --> 00:50:02.760 align:middle line:84%
at the surface of a MOSFET
by a factor of 3 to 4,

00:50:02.760 --> 00:50:03.940 align:middle line:90%
the VT is going to go up.

00:50:03.940 --> 00:50:06.330 align:middle line:90%
It's not going to go down.

00:50:06.330 --> 00:50:09.338 align:middle line:84%
And how can the channel
length impact this?

00:50:09.338 --> 00:50:11.130 align:middle line:84%
Well, it's directly
through this mechanism.

00:50:11.130 --> 00:50:14.160 align:middle line:84%
The normal Fickian
diffusion, the simple version

00:50:14.160 --> 00:50:15.785 align:middle line:84%
of Fick's law, there
was no way people,

00:50:15.785 --> 00:50:17.243 align:middle line:84%
when they use a
simple models, they

00:50:17.243 --> 00:50:19.620 align:middle line:84%
can get that to happen as
a function of this channel.

00:50:19.620 --> 00:50:23.550 align:middle line:84%
They had to invoke
some other thing

00:50:23.550 --> 00:50:26.550 align:middle line:84%
to take an original
Gaussian-like boron

00:50:26.550 --> 00:50:29.910 align:middle line:84%
profile, peaked right
here, and then, in fact,

00:50:29.910 --> 00:50:33.190 align:middle line:84%
move it in closer
to the surface.

00:50:33.190 --> 00:50:35.550 align:middle line:84%
In fact, if you just looked
at these diffusion profiles

00:50:35.550 --> 00:50:37.717 align:middle line:84%
and I didn't say anything
about interstitial fluxes,

00:50:37.717 --> 00:50:39.900 align:middle line:84%
I just gave you these
three profiles and I said,

00:50:39.900 --> 00:50:43.140 align:middle line:84%
OK, look, is that normal
Gaussian Fickian diffusion?

00:50:43.140 --> 00:50:45.220 align:middle line:90%
It can't be.

00:50:45.220 --> 00:50:48.960 align:middle line:84%
I mean, for normal
Fickian diffusion,

00:50:48.960 --> 00:50:52.260 align:middle line:84%
what happens is as the
profile gets broader, sure,

00:50:52.260 --> 00:50:54.480 align:middle line:90%
it gets broader.

00:50:54.480 --> 00:50:57.060 align:middle line:84%
Would you get more
diffusion when

00:50:57.060 --> 00:50:59.940 align:middle line:84%
it's driven by the
flux of the dopant?

00:50:59.940 --> 00:51:01.913 align:middle line:90%
But the peak doesn't change.

00:51:01.913 --> 00:51:04.080 align:middle line:84%
The position of the peak
in normal Fickian diffusion

00:51:04.080 --> 00:51:05.150 align:middle line:90%
never changes.

00:51:05.150 --> 00:51:07.650 align:middle line:84%
If you did your homework and
you did the Gaussian diffusion,

00:51:07.650 --> 00:51:09.487 align:middle line:84%
you found, sure, it
goes down with time,

00:51:09.487 --> 00:51:11.070 align:middle line:84%
but it's not like
the peak shifts over

00:51:11.070 --> 00:51:12.112 align:middle line:90%
to the left or the right.

00:51:12.112 --> 00:51:13.980 align:middle line:90%
It's weird.

00:51:13.980 --> 00:51:16.290 align:middle line:84%
If it's driven by its own
concentration gradient,

00:51:16.290 --> 00:51:19.140 align:middle line:84%
by definition, the
peak doesn't shift.

00:51:19.140 --> 00:51:20.610 align:middle line:84%
But here's an
example of diffusion

00:51:20.610 --> 00:51:22.740 align:middle line:84%
where the peak was
actually shifting.

00:51:22.740 --> 00:51:25.470 align:middle line:84%
The only way to explain that
is some non-Fickian sort

00:51:25.470 --> 00:51:26.040 align:middle line:90%
of phenomena.

00:51:26.040 --> 00:51:27.613 align:middle line:84%
And in fact, people
use this pairing,

00:51:27.613 --> 00:51:30.030 align:middle line:84%
the fact that boron diffuses
as a pair with interstitials,

00:51:30.030 --> 00:51:32.353 align:middle line:84%
and the grades of interstitials
was dragging the bond,

00:51:32.353 --> 00:51:34.020 align:middle line:84%
and so much so that
the peak of the barn

00:51:34.020 --> 00:51:36.190 align:middle line:90%
was moving towards the surface.

00:51:36.190 --> 00:51:38.190 align:middle line:84%
So we're going to talk
about this in more detail

00:51:38.190 --> 00:51:41.070 align:middle line:84%
when we do ion implant damage
and how much interstitials

00:51:41.070 --> 00:51:42.360 align:middle line:90%
are injected and all that.

00:51:42.360 --> 00:51:43.770 align:middle line:90%
But it just gives you a--

00:51:43.770 --> 00:51:46.272 align:middle line:84%
I think it's a nice example of
how the process engineers got

00:51:46.272 --> 00:51:48.480 align:middle line:84%
together with a device people
who couldn't figure out

00:51:48.480 --> 00:51:52.350 align:middle line:84%
what the heck was going on and
developed a process model that

00:51:52.350 --> 00:51:55.080 align:middle line:84%
actually could explain
pretty well the VT

00:51:55.080 --> 00:51:56.520 align:middle line:90%
and predict what it should be.

00:51:56.520 --> 00:51:59.770 align:middle line:90%


00:51:59.770 --> 00:52:03.010 align:middle line:84%
OK, so that's what I want to
say now about this diffusion.

00:52:03.010 --> 00:52:05.020 align:middle line:84%
I'm going to go on
in slide 16 and talk

00:52:05.020 --> 00:52:07.150 align:middle line:84%
about profile
measurement techniques.

00:52:07.150 --> 00:52:10.150 align:middle line:84%
I showed you some
really old photographs

00:52:10.150 --> 00:52:13.480 align:middle line:84%
from Plummer and
Fahey in the late 80s.

00:52:13.480 --> 00:52:15.850 align:middle line:84%
And I talked about
beveling and staining.

00:52:15.850 --> 00:52:19.990 align:middle line:84%
That's one way, but it was
cheap and relatively simple,

00:52:19.990 --> 00:52:23.380 align:middle line:90%
but not totally sophisticated.

00:52:23.380 --> 00:52:26.013 align:middle line:84%
But let me give you
some more examples.

00:52:26.013 --> 00:52:27.430 align:middle line:84%
It's really
critical-- you can see

00:52:27.430 --> 00:52:28.847 align:middle line:84%
from the examples
I've given you--

00:52:28.847 --> 00:52:32.200 align:middle line:84%
to have some method of measuring
the dopant diffusion profile

00:52:32.200 --> 00:52:35.660 align:middle line:84%
as it goes from the surface
into depth in one dimension.

00:52:35.660 --> 00:52:37.720 align:middle line:84%
And actually, if
we're going to explain

00:52:37.720 --> 00:52:39.670 align:middle line:84%
the reverse short
channel effect like this,

00:52:39.670 --> 00:52:41.470 align:middle line:84%
we really need a
two-dimensional map

00:52:41.470 --> 00:52:43.180 align:middle line:90%
of where all the dopants end up.

00:52:43.180 --> 00:52:45.460 align:middle line:90%
That's not trivial.

00:52:45.460 --> 00:52:47.600 align:middle line:84%
One dimension is
pretty sophisticated.

00:52:47.600 --> 00:52:49.540 align:middle line:90%
There are a number of methods.

00:52:49.540 --> 00:52:51.760 align:middle line:84%
Probably one of the
most sophisticated right

00:52:51.760 --> 00:52:54.130 align:middle line:84%
now that you will use in
your research or people

00:52:54.130 --> 00:52:58.420 align:middle line:84%
use in the fab, or in
semiconductor fabrication,

00:52:58.420 --> 00:52:59.972 align:middle line:84%
is secondary ion
mass spectrometry.

00:52:59.972 --> 00:53:02.180 align:middle line:84%
I think we've talked a little
bit about SIMS already.

00:53:02.180 --> 00:53:03.710 align:middle line:84%
But that's probably the
number one technique.

00:53:03.710 --> 00:53:05.047 align:middle line:90%
And it continues to improve.

00:53:05.047 --> 00:53:07.130 align:middle line:84%
It's improved dramatically
over the last 10 years.

00:53:07.130 --> 00:53:10.790 align:middle line:84%
As devices have shrunk, as
junction depths have become

00:53:10.790 --> 00:53:12.830 align:middle line:84%
narrower and narrower,
they've found a way

00:53:12.830 --> 00:53:15.710 align:middle line:84%
to make SIMS higher
and higher resolution.

00:53:15.710 --> 00:53:17.990 align:middle line:84%
SIMS only gives you
the physical number

00:53:17.990 --> 00:53:20.460 align:middle line:84%
of atoms of arsenic or
boron per cubic centimeter.

00:53:20.460 --> 00:53:22.010 align:middle line:84%
It's the physical
chemical amount

00:53:22.010 --> 00:53:25.970 align:middle line:84%
of atoms in the sample at
any given point in depth.

00:53:25.970 --> 00:53:27.710 align:middle line:84%
Sometimes you're
interested in knowing

00:53:27.710 --> 00:53:30.800 align:middle line:84%
not the number of arsenic atoms,
but the number of electrons

00:53:30.800 --> 00:53:32.347 align:middle line:84%
at that point per
cubic centimeter.

00:53:32.347 --> 00:53:33.180 align:middle line:90%
Those are different.

00:53:33.180 --> 00:53:35.750 align:middle line:84%
Remember arsenic, you can
put a lot of doping in,

00:53:35.750 --> 00:53:37.640 align:middle line:84%
but not all of it may
be electrically active.

00:53:37.640 --> 00:53:39.380 align:middle line:84%
Or it may be compensated
by the presence

00:53:39.380 --> 00:53:41.070 align:middle line:90%
of boron or another dopant.

00:53:41.070 --> 00:53:43.160 align:middle line:84%
So there are
electrical techniques

00:53:43.160 --> 00:53:45.120 align:middle line:90%
like spreading resistance.

00:53:45.120 --> 00:53:48.680 align:middle line:84%
We'll talk about one-dimensional
CV and differential vanderpol.

00:53:48.680 --> 00:53:50.420 align:middle line:84%
These measure the
carrier concentration.

00:53:50.420 --> 00:53:53.630 align:middle line:84%
That's not the same as
the dopant concentration.

00:53:53.630 --> 00:53:55.400 align:middle line:84%
So 1D though, is
reasonably sophisticated.

00:53:55.400 --> 00:53:58.047 align:middle line:84%
Two dimension is
still kind of tough.

00:53:58.047 --> 00:53:59.630 align:middle line:84%
The methods are still
being developed.

00:53:59.630 --> 00:54:03.410 align:middle line:84%
They've certainly gotten beyond
the junction staining methods.

00:54:03.410 --> 00:54:05.642 align:middle line:84%
But they're generally
indirect methods.

00:54:05.642 --> 00:54:07.100 align:middle line:84%
They're more
difficult. And this is

00:54:07.100 --> 00:54:09.058 align:middle line:84%
an area with a lot of
research, and development

00:54:09.058 --> 00:54:12.650 align:middle line:84%
is taking place just to
develop the metrology tools

00:54:12.650 --> 00:54:13.800 align:middle line:90%
and techniques.

00:54:13.800 --> 00:54:16.550 align:middle line:84%
Here's an example of some
2D techniques I'll show you.

00:54:16.550 --> 00:54:18.380 align:middle line:84%
Cross-section
transmission electron

00:54:18.380 --> 00:54:21.170 align:middle line:84%
microscopy is a way of
visualizing junctions

00:54:21.170 --> 00:54:22.310 align:middle line:90%
with chemical etching.

00:54:22.310 --> 00:54:25.820 align:middle line:84%
It's like the modern analog
of the old Paul Fahey days,

00:54:25.820 --> 00:54:28.040 align:middle line:84%
look in a microscope after
you stain the junction.

00:54:28.040 --> 00:54:32.150 align:middle line:84%
But it has resolutions that
are a factor of 10 to 100

00:54:32.150 --> 00:54:34.730 align:middle line:90%
higher resolution.

00:54:34.730 --> 00:54:37.770 align:middle line:84%
The scanning probe
microscopy, I'll talk about.

00:54:37.770 --> 00:54:39.380 align:middle line:84%
And the last one is
inverse modeling.

00:54:39.380 --> 00:54:44.240 align:middle line:84%
This is kind of a funny
one, but it actually

00:54:44.240 --> 00:54:47.570 align:middle line:84%
can be very useful
in complicated cases.

00:54:47.570 --> 00:54:49.580 align:middle line:84%
What people do is
they take a device.

00:54:49.580 --> 00:54:52.280 align:middle line:84%
They take all its current
voltage characteristics,

00:54:52.280 --> 00:54:54.170 align:middle line:84%
its capacitance voltage
characteristics.

00:54:54.170 --> 00:54:56.990 align:middle line:84%
They put them all in one giant
database and think about it

00:54:56.990 --> 00:54:59.960 align:middle line:84%
and try to figure out, given
all those characteristics, what

00:54:59.960 --> 00:55:02.030 align:middle line:90%
must be the doping profiles.

00:55:02.030 --> 00:55:05.090 align:middle line:90%
So it's an inverse technique.

00:55:05.090 --> 00:55:07.928 align:middle line:84%
Unfortunately it relies
on knowing really detailed

00:55:07.928 --> 00:55:10.220 align:middle line:84%
electrical models because
you're really extracting this

00:55:10.220 --> 00:55:11.595 align:middle line:84%
all from electrical
measurements.

00:55:11.595 --> 00:55:13.760 align:middle line:84%
So it's not the same as
doing SIMS or whatever,

00:55:13.760 --> 00:55:17.180 align:middle line:84%
but when you get to small
dimensions and two dimensions,

00:55:17.180 --> 00:55:20.990 align:middle line:84%
it is a technique
people try to use.

00:55:20.990 --> 00:55:24.110 align:middle line:84%
OK, so let's look at slide
17 and talk a little bit

00:55:24.110 --> 00:55:24.770 align:middle line:90%
about SIMS.

00:55:24.770 --> 00:55:26.180 align:middle line:84%
I've already mentioned
that in the past,

00:55:26.180 --> 00:55:28.222 align:middle line:84%
but now we're going to
talk about it specifically

00:55:28.222 --> 00:55:30.470 align:middle line:90%
for depth profiling of dopants.

00:55:30.470 --> 00:55:31.880 align:middle line:90%
There are two modes for SIMS.

00:55:31.880 --> 00:55:34.160 align:middle line:84%
There's what's called
dynamic or static.

00:55:34.160 --> 00:55:35.720 align:middle line:84%
Dynamic is what
you typically use.

00:55:35.720 --> 00:55:39.260 align:middle line:84%
Dynamic means as the ion beam
comes in and hits the surface,

00:55:39.260 --> 00:55:41.835 align:middle line:84%
it's sputtering away
a significant amount.

00:55:41.835 --> 00:55:44.210 align:middle line:84%
And it continues to go deeper
and deeper into the surface

00:55:44.210 --> 00:55:47.090 align:middle line:84%
as a function of time, at
some constant sputter rate,

00:55:47.090 --> 00:55:49.160 align:middle line:90%
say 5 angstroms per second.

00:55:49.160 --> 00:55:50.570 align:middle line:90%
It sputters away the surface.

00:55:50.570 --> 00:55:53.840 align:middle line:84%
And it looks at the
atoms that come off it.

00:55:53.840 --> 00:55:54.890 align:middle line:90%
They get ionized.

00:55:54.890 --> 00:55:57.230 align:middle line:84%
It puts them in a mass
spec and it tells you

00:55:57.230 --> 00:55:59.300 align:middle line:84%
at any given depth
what's coming off.

00:55:59.300 --> 00:56:00.900 align:middle line:84%
Static SIMS is a
little different.

00:56:00.900 --> 00:56:04.490 align:middle line:84%
The energy and the angle are
adjusted of the primary ion beam

00:56:04.490 --> 00:56:07.760 align:middle line:84%
such that it doesn't
actually sputter very much.

00:56:07.760 --> 00:56:10.320 align:middle line:84%
It's primarily just taking
off what's at the surface.

00:56:10.320 --> 00:56:12.170 align:middle line:84%
So it's very gentle
and low energy.

00:56:12.170 --> 00:56:15.890 align:middle line:84%
That's just for looking at just
what atoms or molecules are

00:56:15.890 --> 00:56:17.670 align:middle line:90%
at the surface.

00:56:17.670 --> 00:56:19.340 align:middle line:84%
But for depth
profiling of dopants,

00:56:19.340 --> 00:56:22.850 align:middle line:90%
typically using dynamic SIMS.

00:56:22.850 --> 00:56:24.412 align:middle line:84%
How does it work
for depth profiling?

00:56:24.412 --> 00:56:26.870 align:middle line:84%
Well, it's somewhat intuitive,
and you should take yourself

00:56:26.870 --> 00:56:28.078 align:middle line:90%
through these three cartoons.

00:56:28.078 --> 00:56:29.990 align:middle line:84%
I think you'll have a
better understanding.

00:56:29.990 --> 00:56:32.640 align:middle line:84%
First case, I have
a sample of silicon.

00:56:32.640 --> 00:56:35.240 align:middle line:84%
It has some dopant
A up at the top.

00:56:35.240 --> 00:56:37.400 align:middle line:84%
In some depth,
there's a layer of B.

00:56:37.400 --> 00:56:38.900 align:middle line:84%
At this interface,
let's say there's

00:56:38.900 --> 00:56:41.690 align:middle line:84%
a spike of X. It's
a different dopant

00:56:41.690 --> 00:56:44.840 align:middle line:84%
or a different contaminant,
maybe carbon or oxygen.

00:56:44.840 --> 00:56:47.180 align:middle line:84%
And down here it's
doped with C, whatever

00:56:47.180 --> 00:56:48.530 align:middle line:90%
these three elements are.

00:56:48.530 --> 00:56:49.478 align:middle line:90%
So what happens?

00:56:49.478 --> 00:56:51.770 align:middle line:84%
As I'm sputtering, I'm bringing
in my initial ion beam,

00:56:51.770 --> 00:56:53.390 align:middle line:90%
it starts to create a crater.

00:56:53.390 --> 00:56:55.302 align:middle line:84%
And it constantly is
cratering the sample.

00:56:55.302 --> 00:56:57.260 align:middle line:84%
And you're looking off--
as a function of time,

00:56:57.260 --> 00:56:59.720 align:middle line:84%
you're looking at what atoms
come off in a spectrometer.

00:56:59.720 --> 00:57:03.170 align:middle line:84%
So if you look at the intensity
as a function of time,

00:57:03.170 --> 00:57:06.050 align:middle line:84%
the spectrometer can scan
several different masses.

00:57:06.050 --> 00:57:08.930 align:middle line:84%
Well, lo and behold, it
finds for this time period,

00:57:08.930 --> 00:57:11.630 align:middle line:84%
while it's sputtering
through this cap region,

00:57:11.630 --> 00:57:15.540 align:middle line:84%
it just detects dopant A. When
it gets to this interface right

00:57:15.540 --> 00:57:17.820 align:middle line:84%
here, it's starting
to sputter off

00:57:17.820 --> 00:57:21.090 align:middle line:84%
not only a little bit of dopant
A, but a little bit of B,

00:57:21.090 --> 00:57:23.380 align:middle line:90%
and also X pops in.

00:57:23.380 --> 00:57:25.890 align:middle line:84%
And then as you
continue to crater down

00:57:25.890 --> 00:57:29.670 align:middle line:84%
and you get into this point,
you're sputtering off B.

00:57:29.670 --> 00:57:32.670 align:middle line:84%
So you're linearly in time
sputtering through the sample.

00:57:32.670 --> 00:57:35.200 align:middle line:84%
And you collect as a function
of time the intensity.

00:57:35.200 --> 00:57:36.658 align:middle line:84%
So that's what you
get out of SIMS.

00:57:36.658 --> 00:57:39.190 align:middle line:84%
You don't get doping
concentration versus depth.

00:57:39.190 --> 00:57:40.200 align:middle line:90%
You get the intensity.

00:57:40.200 --> 00:57:42.060 align:middle line:84%
How many ions are
coming off per second?

00:57:42.060 --> 00:57:43.770 align:middle line:84%
It counts per
second on a detector

00:57:43.770 --> 00:57:45.900 align:middle line:90%
as a function of sputter time.

00:57:45.900 --> 00:57:49.230 align:middle line:84%
So you have to somehow convert
the x-axis of time into depth.

00:57:49.230 --> 00:57:51.300 align:middle line:84%
Well, that seems
obvious on this plot.

00:57:51.300 --> 00:57:55.205 align:middle line:84%
If you know the sputter
rate, you figure out--

00:57:55.205 --> 00:57:56.580 align:middle line:84%
let's say you
measure at the end.

00:57:56.580 --> 00:57:58.920 align:middle line:84%
You put it in a deck tack
and you measure how deep

00:57:58.920 --> 00:58:00.300 align:middle line:90%
the hole is, the crater is.

00:58:00.300 --> 00:58:02.010 align:middle line:84%
And you assume it's
linear in time.

00:58:02.010 --> 00:58:03.510 align:middle line:84%
Well, then I can
figure out how many

00:58:03.510 --> 00:58:05.010 align:middle line:90%
angstroms came off per second.

00:58:05.010 --> 00:58:07.380 align:middle line:90%
And I can convert time to depth.

00:58:07.380 --> 00:58:08.790 align:middle line:84%
And that's a big
assumption there

00:58:08.790 --> 00:58:10.950 align:middle line:84%
because what you're assuming
is that the sputtering rate is

00:58:10.950 --> 00:58:13.360 align:middle line:84%
constant throughout the entire
experiment and measurement.

00:58:13.360 --> 00:58:14.735 align:middle line:84%
If you have
different materials--

00:58:14.735 --> 00:58:16.750 align:middle line:84%
maybe you're going through
oxides, silicon oxide

00:58:16.750 --> 00:58:19.180 align:middle line:84%
and silicon, sputter rates
differ in those materials.

00:58:19.180 --> 00:58:21.340 align:middle line:84%
So you run into some
distortion of profiles.

00:58:21.340 --> 00:58:22.810 align:middle line:90%
So you have to be very careful.

00:58:22.810 --> 00:58:25.790 align:middle line:84%
But it's an assumption pretty
much that people need to make.

00:58:25.790 --> 00:58:28.270 align:middle line:84%
So you convert the
time axis to depth.

00:58:28.270 --> 00:58:33.730 align:middle line:84%
Intensity, that's even trickier
because it's just intensity.

00:58:33.730 --> 00:58:36.370 align:middle line:84%
It has to be calibrated
to convert that

00:58:36.370 --> 00:58:38.690 align:middle line:90%
to atoms per cubic centimeter.

00:58:38.690 --> 00:58:42.080 align:middle line:84%
So I'll say a few words about
how that conversion is done.

00:58:42.080 --> 00:58:43.710 align:middle line:84%
But let me first
show you just a--

00:58:43.710 --> 00:58:47.808 align:middle line:84%
I took this off the Charles
Evans website, www.cea.com.

00:58:47.808 --> 00:58:49.600 align:middle line:84%
Again, they're a large
commercial company--

00:58:49.600 --> 00:58:51.590 align:middle line:84%
they're probably the
largest in the world--

00:58:51.590 --> 00:58:53.920 align:middle line:84%
international company
that for a business

00:58:53.920 --> 00:58:56.540 align:middle line:90%
does materials analysis.

00:58:56.540 --> 00:58:58.930 align:middle line:84%
And one of their big
thing that they focus on

00:58:58.930 --> 00:59:02.770 align:middle line:84%
is dynamic SIMS, primarily--
well, for a lot of industries,

00:59:02.770 --> 00:59:06.730 align:middle line:84%
primarily for semiconductor
and magnetic industries.

00:59:06.730 --> 00:59:09.730 align:middle line:84%
And this shows you just is
a little thing that they

00:59:09.730 --> 00:59:13.480 align:middle line:84%
like to advertise just to give
you an idea of the detection

00:59:13.480 --> 00:59:16.720 align:middle line:84%
limit, so the number
of parts per billion

00:59:16.720 --> 00:59:19.840 align:middle line:84%
or the percent of an
impurity you can measure.

00:59:19.840 --> 00:59:21.790 align:middle line:84%
It tends to be related,
to a certain extent,

00:59:21.790 --> 00:59:23.330 align:middle line:90%
to the analytical spot size.

00:59:23.330 --> 00:59:26.830 align:middle line:84%
So how big is the little
spot that you're looking at?

00:59:26.830 --> 00:59:29.440 align:middle line:84%
And there are lots of
different acronyms.

00:59:29.440 --> 00:59:30.790 align:middle line:90%
And I apologize for all this.

00:59:30.790 --> 00:59:32.373 align:middle line:84%
If you want to go
on to their website,

00:59:32.373 --> 00:59:34.392 align:middle line:84%
they have each one of
these acronyms is defined.

00:59:34.392 --> 00:59:36.100 align:middle line:84%
In fact, we've talked
about some of them.

00:59:36.100 --> 00:59:37.820 align:middle line:84%
We talked about
earlier in the course,

00:59:37.820 --> 00:59:40.450 align:middle line:84%
we talked about TXRF,
total XY fluorescence.

00:59:40.450 --> 00:59:41.920 align:middle line:90%
It measures about a centimeter.

00:59:41.920 --> 00:59:43.510 align:middle line:90%
It only measures at the surface.

00:59:43.510 --> 00:59:47.830 align:middle line:84%
And it's good for
measuring in this range, 10

00:59:47.830 --> 00:59:50.110 align:middle line:90%
to the 17th atoms per CC.

00:59:50.110 --> 00:59:53.530 align:middle line:84%
The most sense-- as you go down
to get to parts per trillion,

00:59:53.530 --> 00:59:55.923 align:middle line:84%
the only technique that
can get into that range,

00:59:55.923 --> 00:59:58.090 align:middle line:84%
and it's only for certain
elements, is dynamic SIMS.

00:59:58.090 --> 01:00:00.020 align:middle line:84%
You see this little
bubble is in this range.

01:00:00.020 --> 01:00:03.650 align:middle line:84%
It has a spot size
maybe 10 microns.

01:00:03.650 --> 01:00:06.760 align:middle line:84%
Maybe closer to 100 microns
is more typical these days.

01:00:06.760 --> 01:00:08.440 align:middle line:90%
Maybe 100-micron spot size.

01:00:08.440 --> 01:00:11.560 align:middle line:84%
But you can get
elemental information

01:00:11.560 --> 01:00:14.590 align:middle line:84%
down with dynamic SIMS down
into the part per billion,

01:00:14.590 --> 01:00:18.760 align:middle line:84%
and maybe even hundreds of parts
per trillion kind of range.

01:00:18.760 --> 01:00:21.653 align:middle line:84%
So it's what's used for
profiling dopant atoms

01:00:21.653 --> 01:00:23.320 align:middle line:84%
because remember,
dopant atoms can exist

01:00:23.320 --> 01:00:25.390 align:middle line:90%
at very low concentrations.

01:00:25.390 --> 01:00:26.620 align:middle line:90%
10 to the 14th.

01:00:26.620 --> 01:00:28.600 align:middle line:84%
That could be a typical
doping concentrations.

01:00:28.600 --> 01:00:31.017 align:middle line:84%
And SIMS is the only thing
that can measure that right now

01:00:31.017 --> 01:00:34.250 align:middle line:90%
from a chemical point of view.

01:00:34.250 --> 01:00:39.880 align:middle line:84%
So the primary ions
that we typically use--

01:00:39.880 --> 01:00:44.080 align:middle line:84%
I'll just mention there are two
primary ones or common ones.

01:00:44.080 --> 01:00:47.200 align:middle line:84%
Oxygen is an ion
coming in, has come in.

01:00:47.200 --> 01:00:51.580 align:middle line:84%
People use oxygen because it
enhances the secondary ions that

01:00:51.580 --> 01:00:52.180 align:middle line:90%
come off.

01:00:52.180 --> 01:00:54.250 align:middle line:84%
It enhances the
production of positive.

01:00:54.250 --> 01:00:57.290 align:middle line:84%
Oxygen tends to
strip off electrons.

01:00:57.290 --> 01:00:59.170 align:middle line:90%
So O2 plus.

01:00:59.170 --> 01:01:01.060 align:middle line:84%
So it will enhance
the ionization

01:01:01.060 --> 01:01:02.260 align:middle line:90%
of the atoms coming off.

01:01:02.260 --> 01:01:04.750 align:middle line:84%
Because remember, if the
atoms come off as neutrals,

01:01:04.750 --> 01:01:06.913 align:middle line:84%
you can't mass analyze
them in a spectrometer.

01:01:06.913 --> 01:01:08.830 align:middle line:84%
So you've got to get the
atoms off the sample,

01:01:08.830 --> 01:01:11.110 align:middle line:84%
and you have to hope that
they come off ionized.

01:01:11.110 --> 01:01:14.930 align:middle line:84%
And the way you increase the
ionization yield, so to speak,

01:01:14.930 --> 01:01:18.700 align:middle line:84%
is you use oxygen to increase
the positive ion production.

01:01:18.700 --> 01:01:22.450 align:middle line:84%
It's good for groups 1 through
3 if you're trying to measure--

01:01:22.450 --> 01:01:26.260 align:middle line:84%
and the transition
metals in silicon.

01:01:26.260 --> 01:01:27.910 align:middle line:84%
For instance, for
boron, typically

01:01:27.910 --> 01:01:30.580 align:middle line:84%
if you're profiling for
boron, you use O2 plus beam.

01:01:30.580 --> 01:01:33.260 align:middle line:84%
Cesium plus, on the other
hand, is just the opposite.

01:01:33.260 --> 01:01:35.420 align:middle line:84%
It enhances the
negative ion production.

01:01:35.420 --> 01:01:40.750 align:middle line:84%
So it's used for
groups 4 through 7.

01:01:40.750 --> 01:01:43.810 align:middle line:84%
And these are good
electron acceptors,

01:01:43.810 --> 01:01:45.710 align:middle line:84%
and they form negative
secondary ions.

01:01:45.710 --> 01:01:48.458 align:middle line:84%
So arsenic, you would typically
use cesium primary beam.

01:01:48.458 --> 01:01:50.750 align:middle line:84%
And they have machines set
up for these two different--

01:01:50.750 --> 01:01:52.417 align:middle line:84%
so you use a different
machine depending

01:01:52.417 --> 01:01:53.680 align:middle line:90%
on what your profiling yield.

01:01:53.680 --> 01:01:56.210 align:middle line:84%
Now, the ion yields, when
I mean the ion yield--

01:01:56.210 --> 01:01:59.530 align:middle line:84%
so that's the number
of ionized species

01:01:59.530 --> 01:02:02.450 align:middle line:84%
that are coming off
of some element,

01:02:02.450 --> 01:02:04.930 align:middle line:84%
say arsenic, compared to the
total amount of sputtering

01:02:04.930 --> 01:02:06.610 align:middle line:90%
of the silicon, that yield.

01:02:06.610 --> 01:02:08.720 align:middle line:84%
That depends on the
matrix material.

01:02:08.720 --> 01:02:12.940 align:middle line:84%
So if you have arsenic at the
same concentration in oxide

01:02:12.940 --> 01:02:15.160 align:middle line:84%
and in silicon at the
identical concentration,

01:02:15.160 --> 01:02:17.540 align:middle line:84%
the ionization yield
will be different.

01:02:17.540 --> 01:02:19.572 align:middle line:84%
So it will come off with
different intensities.

01:02:19.572 --> 01:02:21.030 align:middle line:84%
So that's called
the matrix effect.

01:02:21.030 --> 01:02:22.238 align:middle line:90%
So that's a bit of a problem.

01:02:22.238 --> 01:02:27.040 align:middle line:84%
So the measured intensity
has to be measured

01:02:27.040 --> 01:02:29.380 align:middle line:84%
on a test sample
that's calibrated where

01:02:29.380 --> 01:02:30.610 align:middle line:90%
you know the concentration.

01:02:30.610 --> 01:02:32.950 align:middle line:84%
And you compare that
intensity on the same day

01:02:32.950 --> 01:02:35.990 align:middle line:84%
to whatever's coming off
of your unknown sample.

01:02:35.990 --> 01:02:38.260 align:middle line:84%
And so it's always
calibrated to a known sample.

01:02:38.260 --> 01:02:40.840 align:middle line:84%
And that's one of the
big drawbacks of SIMS.

01:02:40.840 --> 01:02:41.632 align:middle line:90%
You need standards.

01:02:41.632 --> 01:02:43.423 align:middle line:84%
It's not an absolute
measurement technique.

01:02:43.423 --> 01:02:44.410 align:middle line:90%
It's always relative.

01:02:44.410 --> 01:02:47.880 align:middle line:84%
It's only as good
as your standards.

01:02:47.880 --> 01:02:51.530 align:middle line:84%
And in fact, on slide 21, I have
an example of some actual SIMS

01:02:51.530 --> 01:02:54.740 align:middle line:90%
data and how people quantify.

01:02:54.740 --> 01:02:57.170 align:middle line:84%
The x-axis we talked about,
quantifying is not too bad.

01:02:57.170 --> 01:02:58.310 align:middle line:90%
You use a deck tack.

01:02:58.310 --> 01:02:59.800 align:middle line:84%
You assume constant
sputter rate.

01:02:59.800 --> 01:03:00.795 align:middle line:90%
You cross your fingers.

01:03:00.795 --> 01:03:02.420 align:middle line:84%
And that's how you
get the depth scale.

01:03:02.420 --> 01:03:05.120 align:middle line:84%
How do I get the y scale,
which was originally intensity?

01:03:05.120 --> 01:03:07.370 align:middle line:84%
I need to convert
that to concentration.

01:03:07.370 --> 01:03:09.250 align:middle line:84%
Well, typically
what people do is

01:03:09.250 --> 01:03:11.000 align:middle line:84%
they take a sample
that was ion implanted.

01:03:11.000 --> 01:03:12.500 align:middle line:84%
And again, we haven't
talked about implantation.

01:03:12.500 --> 01:03:13.580 align:middle line:90%
That's next lecture.

01:03:13.580 --> 01:03:17.420 align:middle line:84%
Implantation is electrical means
of very accurately controlling

01:03:17.420 --> 01:03:21.020 align:middle line:84%
the integrated dose, the
integral under the curve,

01:03:21.020 --> 01:03:25.100 align:middle line:84%
of an element that you
implant into a sample.

01:03:25.100 --> 01:03:27.230 align:middle line:84%
And that accuracy
of that control

01:03:27.230 --> 01:03:29.780 align:middle line:84%
makes the implanter
a very good way

01:03:29.780 --> 01:03:32.420 align:middle line:84%
of generating SIM standards
because the implanter can

01:03:32.420 --> 01:03:36.590 align:middle line:84%
exactly control the total number
of atoms per square centimeter

01:03:36.590 --> 01:03:37.850 align:middle line:90%
that go into the sample.

01:03:37.850 --> 01:03:40.010 align:middle line:84%
And in fact, this was
a phosphorus implant

01:03:40.010 --> 01:03:44.000 align:middle line:84%
at a total dose of 1 times
10 to the 14th phosphorus

01:03:44.000 --> 01:03:45.120 align:middle line:90%
per square centimeter.

01:03:45.120 --> 01:03:46.760 align:middle line:90%
So that's given as a known.

01:03:46.760 --> 01:03:51.430 align:middle line:84%
So once we know that, since we
know this area under the curve,

01:03:51.430 --> 01:03:54.280 align:middle line:84%
we can then convert
intensity coming off

01:03:54.280 --> 01:03:58.000 align:middle line:84%
on that given day to a certain
concentration of phosphorus.

01:03:58.000 --> 01:04:00.170 align:middle line:84%
So every time we want
to measure an unknown--

01:04:00.170 --> 01:04:02.230 align:middle line:84%
so the right-hand
sample was unknown.

01:04:02.230 --> 01:04:04.385 align:middle line:84%
The left-hand sample,
the concentration

01:04:04.385 --> 01:04:06.010 align:middle line:84%
was known because it
was ion implanted.

01:04:06.010 --> 01:04:08.120 align:middle line:90%
So you use a known dose.

01:04:08.120 --> 01:04:12.610 align:middle line:84%
So from this integrated
ion implant dose,

01:04:12.610 --> 01:04:14.590 align:middle line:84%
I can generate a
sensitivity factor

01:04:14.590 --> 01:04:17.770 align:middle line:84%
that enables me to convert
from intensity coming off

01:04:17.770 --> 01:04:21.140 align:middle line:84%
to a phosphorus concentration
on the unknown sample.

01:04:21.140 --> 01:04:24.820 align:middle line:84%
And so this is what I get, for
example, on an unknown sample.

01:04:24.820 --> 01:04:28.900 align:middle line:84%
But you always need a standard
which you trust in order

01:04:28.900 --> 01:04:29.790 align:middle line:90%
to compare it to.

01:04:29.790 --> 01:04:31.540 align:middle line:84%
And it has to be
compared on that same day

01:04:31.540 --> 01:04:34.180 align:middle line:84%
because the SIMS machines,
their calibrations

01:04:34.180 --> 01:04:35.750 align:middle line:90%
can be changing from day to day.

01:04:35.750 --> 01:04:38.110 align:middle line:84%
And it has to be, in
fact, a sample hopefully

01:04:38.110 --> 01:04:41.050 align:middle line:84%
that has roughly the same total
amount of peak phosphorus as

01:04:41.050 --> 01:04:41.770 align:middle line:90%
in your unknown.

01:04:41.770 --> 01:04:44.020 align:middle line:84%
If it was dramatically
different, [? MIP ?] effects.

01:04:44.020 --> 01:04:45.603 align:middle line:84%
And it should be in
the same material.

01:04:45.603 --> 01:04:48.580 align:middle line:84%
Notice this was phosphorus
in silicon in a known sample.

01:04:48.580 --> 01:04:50.960 align:middle line:84%
This is phosphorus in
silicon in an unknown sample.

01:04:50.960 --> 01:04:52.918 align:middle line:84%
You wouldn't want to use
phosphorus and silicon

01:04:52.918 --> 01:04:56.240 align:middle line:84%
dioxide to calibrate this
because the matrix effect would

01:04:56.240 --> 01:04:58.980 align:middle line:90%
kill you.

01:04:58.980 --> 01:05:00.870 align:middle line:84%
OK, so that's an example
of a practical idea

01:05:00.870 --> 01:05:03.750 align:middle line:90%
of how the SIMS actually works.

01:05:03.750 --> 01:05:05.070 align:middle line:90%
These are some considerations.

01:05:05.070 --> 01:05:07.278 align:middle line:84%
People are very concerned
about the depth resolution.

01:05:07.278 --> 01:05:07.950 align:middle line:90%
What do I mean?

01:05:07.950 --> 01:05:10.075 align:middle line:84%
Actually, let me go back
for a minute for the depth

01:05:10.075 --> 01:05:14.490 align:middle line:84%
resolution-- is let's say this
actual sample is really a box.

01:05:14.490 --> 01:05:16.590 align:middle line:84%
Let's say it's really
a box-like profile.

01:05:16.590 --> 01:05:19.020 align:middle line:84%
What SIMS does to it is
it smears it out a little.

01:05:19.020 --> 01:05:21.360 align:middle line:84%
The edges are not perfectly
straight up and down.

01:05:21.360 --> 01:05:24.240 align:middle line:84%
They have a little bit
of exponential decay

01:05:24.240 --> 01:05:25.920 align:middle line:90%
on the front and the back.

01:05:25.920 --> 01:05:27.060 align:middle line:90%
How much of that is real?

01:05:27.060 --> 01:05:29.220 align:middle line:84%
Is the phosphorus really
decaying exponentially?

01:05:29.220 --> 01:05:32.340 align:middle line:84%
Or is it really a
box-like profile?

01:05:32.340 --> 01:05:34.980 align:middle line:84%
What effects determine
how well I can

01:05:34.980 --> 01:05:41.130 align:middle line:90%
resolve the profile in depth?

01:05:41.130 --> 01:05:43.250 align:middle line:84%
So these are some
considerations.

01:05:43.250 --> 01:05:45.422 align:middle line:84%
The depth resolution
depends on the element

01:05:45.422 --> 01:05:47.630 align:middle line:84%
you're profiling-- phosphorous
or boron or whatever--

01:05:47.630 --> 01:05:51.350 align:middle line:84%
and the matrix that it's in,
because after all, the impact

01:05:51.350 --> 01:05:53.690 align:middle line:84%
conditions-- remember,
these primary cesium ions

01:05:53.690 --> 01:05:54.530 align:middle line:90%
are coming in.

01:05:54.530 --> 01:05:57.500 align:middle line:84%
They're hitting the
phosphorous or the arsenic,

01:05:57.500 --> 01:06:00.060 align:middle line:84%
and they're imparting
energy to it.

01:06:00.060 --> 01:06:02.450 align:middle line:84%
So of course, they can knock
that arsenic or phosphorus

01:06:02.450 --> 01:06:03.260 align:middle line:90%
in a little deeper.

01:06:03.260 --> 01:06:05.720 align:middle line:84%
And of course they could
smear out a profile.

01:06:05.720 --> 01:06:08.780 align:middle line:84%
So you try to change it so
you can minimize the amount

01:06:08.780 --> 01:06:11.420 align:middle line:90%
of ion damage or ion smearing.

01:06:11.420 --> 01:06:15.260 align:middle line:84%
For sputter depth, the deeper
you go into that and the deeper

01:06:15.260 --> 01:06:17.870 align:middle line:84%
you make your crater, the more
the bottom of the crater gets

01:06:17.870 --> 01:06:20.780 align:middle line:84%
roughened just by the sputtering
process as a random process.

01:06:20.780 --> 01:06:23.450 align:middle line:84%
When you have a rough
bottom to your crater, well,

01:06:23.450 --> 01:06:26.360 align:middle line:84%
you're pulling atoms off from
slightly different depths

01:06:26.360 --> 01:06:27.840 align:middle line:90%
at that point in space.

01:06:27.840 --> 01:06:30.780 align:middle line:84%
So the deeper you
sputter, the worse

01:06:30.780 --> 01:06:32.030 align:middle line:90%
the depth resolution for SIMS.

01:06:32.030 --> 01:06:34.000 align:middle line:84%
So if you want to
measure a sharp profile,

01:06:34.000 --> 01:06:35.750 align:middle line:84%
try to put it near the
surface, and you'll

01:06:35.750 --> 01:06:37.730 align:middle line:84%
get much more box-like
profile than putting

01:06:37.730 --> 01:06:41.130 align:middle line:84%
it 1 or 2 microns in where the
sputtering process has roughened

01:06:41.130 --> 01:06:43.620 align:middle line:90%
the bottom of your crater.

01:06:43.620 --> 01:06:46.350 align:middle line:84%
So what people have
improved these days

01:06:46.350 --> 01:06:48.990 align:middle line:84%
to try to get sputtering
processes that

01:06:48.990 --> 01:06:52.080 align:middle line:84%
are as smooth as possible
by rotating the sample,

01:06:52.080 --> 01:06:55.230 align:middle line:84%
and rastering the beam, and
trying to make it really

01:06:55.230 --> 01:06:59.460 align:middle line:84%
a nice, flat, perfectly
shaped crater bottom.

01:06:59.460 --> 01:07:02.040 align:middle line:84%
So they've done a
lot of techniques.

01:07:02.040 --> 01:07:04.380 align:middle line:84%
Also, these days they have
ultra low-energy SIMS has

01:07:04.380 --> 01:07:06.270 align:middle line:84%
been developed where
the incoming beam has

01:07:06.270 --> 01:07:10.380 align:middle line:84%
such a low energy, it doesn't
perturb the profiles too much.

01:07:10.380 --> 01:07:12.750 align:middle line:84%
And that's an important
low-energy SIMS

01:07:12.750 --> 01:07:15.630 align:middle line:84%
that's been developed
in the last 10 years.

01:07:15.630 --> 01:07:17.130 align:middle line:84%
OK, so that's
chemical measurements.

01:07:17.130 --> 01:07:18.300 align:middle line:90%
How about electrical?

01:07:18.300 --> 01:07:21.825 align:middle line:84%
Well, remember I talked
about beveling and staining?

01:07:21.825 --> 01:07:23.700 align:middle line:84%
Well, you don't have to
just bevel and stain.

01:07:23.700 --> 01:07:26.033 align:middle line:84%
You can actually bevel, just
like I talked about before.

01:07:26.033 --> 01:07:30.330 align:middle line:84%
You create this surface that's
beveled at a certain angle.

01:07:30.330 --> 01:07:33.130 align:middle line:84%
And instead of staining,
you take two little probes

01:07:33.130 --> 01:07:35.670 align:middle line:84%
and you measure the resistance
between those two probes.

01:07:35.670 --> 01:07:38.490 align:middle line:84%
You flow a current and
measure the voltage drop

01:07:38.490 --> 01:07:42.140 align:middle line:84%
as a function of lateral
distance along the bevel.

01:07:42.140 --> 01:07:44.730 align:middle line:84%
As you move along the
bevel laterally, of course

01:07:44.730 --> 01:07:45.980 align:middle line:90%
you're also moving in depth.

01:07:45.980 --> 01:07:49.070 align:middle line:84%
So you're essentially spreading
out by the cosine theta.

01:07:49.070 --> 01:07:50.930 align:middle line:84%
You're spreading out--
or the sine theta.

01:07:50.930 --> 01:07:52.430 align:middle line:84%
You're spreading
out that profile.

01:07:52.430 --> 01:07:53.870 align:middle line:90%
So you can move laterally.

01:07:53.870 --> 01:07:56.300 align:middle line:84%
And literally, it takes
the probes on a machine,

01:07:56.300 --> 01:07:59.300 align:middle line:84%
moves it laterally
by certain steps.

01:07:59.300 --> 01:08:03.410 align:middle line:84%
And you can convert this, then,
to a resistivity, or resistance

01:08:03.410 --> 01:08:05.180 align:middle line:90%
plot, as a function of depth.

01:08:05.180 --> 01:08:11.190 align:middle line:84%
And you convert resistivity
into carrier concentration.

01:08:11.190 --> 01:08:13.550 align:middle line:84%
So this measures the
doping concentration

01:08:13.550 --> 01:08:15.770 align:middle line:90%
versus depth, not the dopant.

01:08:15.770 --> 01:08:19.069 align:middle line:84%
Doping refers to the
electrons or holes.

01:08:19.069 --> 01:08:21.770 align:middle line:84%
So it's complementary
to SIMS, which provides

01:08:21.770 --> 01:08:24.649 align:middle line:90%
the chemical information.

01:08:24.649 --> 01:08:27.109 align:middle line:84%
The depth resolution
is not nearly as good.

01:08:27.109 --> 01:08:29.062 align:middle line:84%
I mean, with
spreading resistance,

01:08:29.062 --> 01:08:30.770 align:middle line:84%
you're lucky to measure
a junction that's

01:08:30.770 --> 01:08:32.180 align:middle line:90%
1,000 angstroms deep.

01:08:32.180 --> 01:08:34.140 align:middle line:84%
Typically with SIMS,
you can measure

01:08:34.140 --> 01:08:36.800 align:middle line:90%
100-angstrom deep junctions.

01:08:36.800 --> 01:08:39.140 align:middle line:84%
And the big problem is, again,
it needs some standards.

01:08:39.140 --> 01:08:42.500 align:middle line:84%
You need to know how to convert
how from resistivity to carrier

01:08:42.500 --> 01:08:43.290 align:middle line:90%
concentration.

01:08:43.290 --> 01:08:44.720 align:middle line:84%
So you need to
know these curves.

01:08:44.720 --> 01:08:47.630 align:middle line:84%
There's some famous curves
on the Silicon website.

01:08:47.630 --> 01:08:49.939 align:middle line:84%
This company Silicon
does spreading resistance

01:08:49.939 --> 01:08:51.213 align:middle line:90%
for commercial purposes.

01:08:51.213 --> 01:08:52.880 align:middle line:84%
You can go onto there,
and they show you

01:08:52.880 --> 01:08:53.922 align:middle line:90%
their calibration curves.

01:08:53.922 --> 01:08:55.937 align:middle line:84%
But if you have a material
other than silicon,

01:08:55.937 --> 01:08:57.979 align:middle line:84%
single crystal-- let's
say you have polysilicon--

01:08:57.979 --> 01:09:01.340 align:middle line:84%
the relationship between
carrier concentration N

01:09:01.340 --> 01:09:04.825 align:middle line:84%
and the dopant concentration
is not very well understood.

01:09:04.825 --> 01:09:06.200 align:middle line:84%
Or if you have
silicon germanium,

01:09:06.200 --> 01:09:07.399 align:middle line:90%
there are no standards.

01:09:07.399 --> 01:09:10.250 align:middle line:84%
So spreading resistance
is OK, but it

01:09:10.250 --> 01:09:14.300 align:middle line:90%
does have some limitations.

01:09:14.300 --> 01:09:16.180 align:middle line:84%
I won't go through this
in any great detail.

01:09:16.180 --> 01:09:17.816 align:middle line:90%
This is shown on slide 25.

01:09:17.816 --> 01:09:18.899 align:middle line:90%
I'm referring you to the--

01:09:18.899 --> 01:09:20.950 align:middle line:84%
I pulled this off
the Silicon website.

01:09:20.950 --> 01:09:24.370 align:middle line:84%
But in fact, even in
the most perfect case,

01:09:24.370 --> 01:09:28.439 align:middle line:84%
you can try to correct
the data for artifacts

01:09:28.439 --> 01:09:31.890 align:middle line:84%
by solving Poisson's equation
to account for things like space

01:09:31.890 --> 01:09:34.380 align:middle line:84%
charge layers where you have
an N and a P region meeting

01:09:34.380 --> 01:09:35.430 align:middle line:90%
and things like that.

01:09:35.430 --> 01:09:36.930 align:middle line:84%
There's a lot of
literature on this.

01:09:36.930 --> 01:09:40.080 align:middle line:84%
But you can see it's
measuring junctions

01:09:40.080 --> 01:09:43.920 align:middle line:84%
that are pretty deep, microns
deep, not hundreds of angstroms.

01:09:43.920 --> 01:09:46.380 align:middle line:84%
But it can be used to
measure the well profile

01:09:46.380 --> 01:09:48.330 align:middle line:90%
and things like that.

01:09:48.330 --> 01:09:51.550 align:middle line:84%
Slide 26 actually has kind
of an interesting technique.

01:09:51.550 --> 01:09:55.110 align:middle line:84%
It's not quantitative, but
if you want to talk about 2D,

01:09:55.110 --> 01:09:56.260 align:middle line:90%
it can work.

01:09:56.260 --> 01:09:57.900 align:middle line:90%
This is a cross-section TEM.

01:09:57.900 --> 01:10:02.520 align:middle line:84%
So you're taking a sample
from a silicon MOSFET

01:10:02.520 --> 01:10:04.470 align:middle line:84%
and you've cut it and
cross-sectioned it.

01:10:04.470 --> 01:10:07.260 align:middle line:84%
And you've made that thickness
of that specimen only about

01:10:07.260 --> 01:10:09.363 align:middle line:90%
2,000 angstroms thick.

01:10:09.363 --> 01:10:12.030 align:middle line:84%
There's special ways of cutting
through and cross-sectioning it.

01:10:12.030 --> 01:10:13.410 align:middle line:84%
And then you send
electrons through

01:10:13.410 --> 01:10:15.202 align:middle line:84%
and you look at their
diffraction patterns.

01:10:15.202 --> 01:10:16.800 align:middle line:84%
So you can actually
image the gate,

01:10:16.800 --> 01:10:19.200 align:middle line:90%
the gate oxide, the silicon.

01:10:19.200 --> 01:10:20.947 align:middle line:84%
And interestingly,
what people have done

01:10:20.947 --> 01:10:23.280 align:middle line:84%
is you take the specimen after
you've cross-sectioned it

01:10:23.280 --> 01:10:25.110 align:middle line:90%
and you dump it in some acid.

01:10:25.110 --> 01:10:27.960 align:middle line:84%
And it turns out the acid
etches much more rapidly

01:10:27.960 --> 01:10:30.150 align:middle line:84%
regions that are
very heavily N-type.

01:10:30.150 --> 01:10:33.090 align:middle line:84%
So when you etch that region,
you change the thickness

01:10:33.090 --> 01:10:35.610 align:middle line:84%
of the sample and you change
the transparency of the sample

01:10:35.610 --> 01:10:37.030 align:middle line:90%
to electron beams.

01:10:37.030 --> 01:10:40.080 align:middle line:84%
So where it's very heavily
doped, it appears very light.

01:10:40.080 --> 01:10:42.690 align:middle line:84%
The electrons don't--
they go right through.

01:10:42.690 --> 01:10:46.980 align:middle line:84%
So the contrast
on this gives you

01:10:46.980 --> 01:10:48.360 align:middle line:90%
good qualitative information.

01:10:48.360 --> 01:10:50.610 align:middle line:84%
And people believe
that it delineates

01:10:50.610 --> 01:10:53.760 align:middle line:84%
this line, this dark line,
corresponds to a concentration

01:10:53.760 --> 01:10:55.020 align:middle line:90%
of about 10 to the 19th.

01:10:55.020 --> 01:10:58.140 align:middle line:84%
So it gives you an idea of where
the edge of the source and drain

01:10:58.140 --> 01:10:59.730 align:middle line:90%
might be, but it's qualitative.

01:10:59.730 --> 01:11:03.290 align:middle line:90%
And it's very time-consuming.

01:11:03.290 --> 01:11:06.490 align:middle line:84%
There's another 2D technique,
again, based on beveling.

01:11:06.490 --> 01:11:08.530 align:middle line:84%
Again, we'll go back to
the same old bevel idea.

01:11:08.530 --> 01:11:10.660 align:middle line:84%
Here's a MOSFET with
a source and drain.

01:11:10.660 --> 01:11:15.190 align:middle line:84%
People actually take an
atomic force microscope

01:11:15.190 --> 01:11:18.190 align:middle line:90%
with AFM cantilever, little tip.

01:11:18.190 --> 01:11:21.730 align:middle line:84%
And they measure where
they are across the sample.

01:11:21.730 --> 01:11:25.250 align:middle line:84%
And they measure at
each point, a CV curve.

01:11:25.250 --> 01:11:28.360 align:middle line:84%
So it's like very locally
doing a capacitance voltage

01:11:28.360 --> 01:11:30.340 align:middle line:84%
measurement where
the tip corresponds

01:11:30.340 --> 01:11:34.120 align:middle line:90%
to the metal point of the CV.

01:11:34.120 --> 01:11:37.390 align:middle line:84%
And the backside contact
corresponds to the back.

01:11:37.390 --> 01:11:40.360 align:middle line:84%
And you're actually measuring--
you know from CV-- remember,

01:11:40.360 --> 01:11:42.100 align:middle line:90%
we talked about CV on dots.

01:11:42.100 --> 01:11:44.530 align:middle line:84%
If I put a dot over a
uniformly doped sample,

01:11:44.530 --> 01:11:47.980 align:middle line:84%
you can extract from the CV
the local doping concentration.

01:11:47.980 --> 01:11:50.290 align:middle line:84%
Well, they're doing it, but
here on a very small scale

01:11:50.290 --> 01:11:52.220 align:middle line:90%
with a very small AFM tip.

01:11:52.220 --> 01:11:55.300 align:middle line:84%
So this is scanning
capacitance microscopy.

01:11:55.300 --> 01:11:59.620 align:middle line:84%
It's very tricky, though, the
spatial resolution issues,

01:11:59.620 --> 01:12:01.060 align:middle line:90%
limited by the probe size.

01:12:01.060 --> 01:12:02.600 align:middle line:90%
The tip is only so small.

01:12:02.600 --> 01:12:04.830 align:middle line:84%
And then it has fringing
electric fields.

01:12:04.830 --> 01:12:06.620 align:middle line:84%
So the actual area
of the capacitor

01:12:06.620 --> 01:12:09.470 align:middle line:84%
that you're creating with the
tip is somewhat uncertain.

01:12:09.470 --> 01:12:14.000 align:middle line:84%
It has to be modeled with
sophisticated ENM modeling.

01:12:14.000 --> 01:12:15.860 align:middle line:84%
But just to give you
an idea, again, this

01:12:15.860 --> 01:12:18.830 align:middle line:84%
is the website if you want to
go there, if you're interested.

01:12:18.830 --> 01:12:22.880 align:middle line:84%
Basically how it works
on an N-type CV curve,

01:12:22.880 --> 01:12:27.320 align:middle line:84%
basically it takes DC by DV,
the derivative of the capacitor

01:12:27.320 --> 01:12:28.820 align:middle line:90%
with respect to the voltage.

01:12:28.820 --> 01:12:32.090 align:middle line:84%
And you can relate that locally
to the carrier concentration.

01:12:32.090 --> 01:12:39.230 align:middle line:84%
Very similar to what you do in
1D CV, but now over a surface.

01:12:39.230 --> 01:12:41.780 align:middle line:84%
And in fact, here's
a beveled junction

01:12:41.780 --> 01:12:45.000 align:middle line:84%
where this region
corresponds to phosphorus.

01:12:45.000 --> 01:12:47.370 align:middle line:84%
This is the scanning
capacitance microscopy image.

01:12:47.370 --> 01:12:48.590 align:middle line:90%
So this is very high doped.

01:12:48.590 --> 01:12:51.920 align:middle line:84%
This is the junction
region in p-type silicon

01:12:51.920 --> 01:12:52.970 align:middle line:90%
near the edge of a mask.

01:12:52.970 --> 01:12:53.750 align:middle line:90%
So here's a mask.

01:12:53.750 --> 01:12:55.250 align:middle line:90%
There's no phosphorus over here.

01:12:55.250 --> 01:12:56.690 align:middle line:90%
It's lightly doped.

01:12:56.690 --> 01:12:58.100 align:middle line:90%
So it's tricky.

01:12:58.100 --> 01:12:59.600 align:middle line:84%
It's still under
development, but it

01:12:59.600 --> 01:13:07.370 align:middle line:84%
is kind of a popular topic
for modern metrology.

01:13:07.370 --> 01:13:09.210 align:middle line:84%
So let me just summarize
about techniques

01:13:09.210 --> 01:13:10.210 align:middle line:90%
for profile measurement.

01:13:10.210 --> 01:13:12.400 align:middle line:84%
We talked about SIMS,
the most popular.

01:13:12.400 --> 01:13:15.280 align:middle line:84%
It does very good 1D
profiles in depth,

01:13:15.280 --> 01:13:17.980 align:middle line:84%
excellent as the best
sensitivity of any technique

01:13:17.980 --> 01:13:20.110 align:middle line:90%
to the dopant concentration.

01:13:20.110 --> 01:13:22.192 align:middle line:90%
Excellent depth resolution.

01:13:22.192 --> 01:13:23.650 align:middle line:84%
Methods are still
under development

01:13:23.650 --> 01:13:24.700 align:middle line:90%
trying to improve it.

01:13:24.700 --> 01:13:27.070 align:middle line:84%
The very near surface
region is troublesome,

01:13:27.070 --> 01:13:29.232 align:middle line:84%
but there have been
recent improvements.

01:13:29.232 --> 01:13:30.940 align:middle line:84%
You have to watch out
for matrix effects.

01:13:30.940 --> 01:13:34.120 align:middle line:84%
If you're profiling a dopant
in oxide or nitride or silicon,

01:13:34.120 --> 01:13:36.160 align:middle line:84%
the ion yield
varies dramatically,

01:13:36.160 --> 01:13:37.990 align:middle line:90%
it has to be calibrated.

01:13:37.990 --> 01:13:40.728 align:middle line:84%
Spreading resistance is
only generally mostly

01:13:40.728 --> 01:13:42.520 align:middle line:84%
one-dimensional, although
people are trying

01:13:42.520 --> 01:13:45.970 align:middle line:90%
to do it two-dimensional.

01:13:45.970 --> 01:13:49.690 align:middle line:84%
But it measures carriers, so
the active electrons and holes.

01:13:49.690 --> 01:13:51.190 align:middle line:90%
Pretty good sensitivity.

01:13:51.190 --> 01:13:53.590 align:middle line:90%
Depth resolution is not great.

01:13:53.590 --> 01:13:55.910 align:middle line:84%
And it's hard to do
shallow junctions.

01:13:55.910 --> 01:13:57.910 align:middle line:84%
And you need to do some
electromagnetic modeling

01:13:57.910 --> 01:13:59.320 align:middle line:90%
to really understand it.

01:13:59.320 --> 01:14:01.810 align:middle line:84%
These newer techniques
are kind of exciting.

01:14:01.810 --> 01:14:03.610 align:middle line:84%
These two-dimensional
scanning capacitance

01:14:03.610 --> 01:14:05.620 align:middle line:84%
and scanning
resistance microscopy

01:14:05.620 --> 01:14:10.420 align:middle line:84%
with using small probes
are very interesting.

01:14:10.420 --> 01:14:13.220 align:middle line:84%
They do rely on
beveling, but there's

01:14:13.220 --> 01:14:15.470 align:middle line:84%
a lot of advanced
models for the process

01:14:15.470 --> 01:14:17.792 align:middle line:84%
itself that are being
developed in R&D today

01:14:17.792 --> 01:14:19.250 align:middle line:84%
to try to come up
with a better way

01:14:19.250 --> 01:14:23.000 align:middle line:84%
to get quantitative
two-dimensional dopant profile

01:14:23.000 --> 01:14:24.900 align:middle line:90%
measurements.

01:14:24.900 --> 01:14:27.380 align:middle line:84%
So summarizing on what
we've talked about so

01:14:27.380 --> 01:14:30.470 align:middle line:84%
far on dopant diffusion,
we said that they

01:14:30.470 --> 01:14:32.720 align:middle line:84%
diffuse by interacting with
point defects, vacancies,

01:14:32.720 --> 01:14:34.850 align:middle line:90%
and interstitials.

01:14:34.850 --> 01:14:37.100 align:middle line:84%
The diffusivity is proportional
to the concentration

01:14:37.100 --> 01:14:39.530 align:middle line:90%
of those point defects.

01:14:39.530 --> 01:14:41.180 align:middle line:84%
These point defect
concentrations

01:14:41.180 --> 01:14:43.920 align:middle line:84%
go up exponentially as I
increase the temperature.

01:14:43.920 --> 01:14:47.480 align:middle line:84%
And so the diffusivity
goes up exponentially.

01:14:47.480 --> 01:14:50.600 align:middle line:84%
They can also be changed by
things other than temperature--

01:14:50.600 --> 01:14:53.330 align:middle line:84%
the local Fermi level-- the
local doping concentration, that

01:14:53.330 --> 01:14:54.110 align:middle line:90%
is.

01:14:54.110 --> 01:14:56.690 align:middle line:84%
Ion implant damage, as we'll
see in the next chapter,

01:14:56.690 --> 01:14:58.790 align:middle line:84%
can change the point
defect concentration.

01:14:58.790 --> 01:15:02.090 align:middle line:84%
Surface processes like oxidation
and nitrogen change it.

01:15:02.090 --> 01:15:05.370 align:middle line:84%
All of these affect the
effect of diffusivity.

01:15:05.370 --> 01:15:08.090 align:middle line:84%
So the dopant diffusivity
can vary in space.

01:15:08.090 --> 01:15:09.740 align:middle line:90%
It can vary in time.

01:15:09.740 --> 01:15:13.040 align:middle line:84%
All of that means that we cannot
calculate accurate profiles

01:15:13.040 --> 01:15:14.840 align:middle line:90%
in Silicon devices by hand.

01:15:14.840 --> 01:15:16.880 align:middle line:84%
We're pretty much have
to monitor all that

01:15:16.880 --> 01:15:19.310 align:middle line:90%
by doing numerical solutions.

01:15:19.310 --> 01:15:22.100 align:middle line:84%
There's been a lot of progress
in the last 10 or 15 years

01:15:22.100 --> 01:15:26.450 align:middle line:84%
on getting physically based
models for dopant diffusion that

01:15:26.450 --> 01:15:29.720 align:middle line:84%
will actually help you
predict electrical behavior.

01:15:29.720 --> 01:15:31.580 align:middle line:84%
These simulators-- and
we'll talk about it

01:15:31.580 --> 01:15:34.217 align:middle line:84%
more when we give a
lecture on SUPREM IV.

01:15:34.217 --> 01:15:36.050 align:middle line:84%
They allow you to fully
couple the diffusion

01:15:36.050 --> 01:15:37.170 align:middle line:90%
of the point defects.

01:15:37.170 --> 01:15:39.380 align:middle line:84%
So you solve for the
diffusion of the interstitials

01:15:39.380 --> 01:15:41.960 align:middle line:84%
and vacancies, and you solve
diffusion of the dopants

01:15:41.960 --> 01:15:43.075 align:middle line:90%
at the same time.

01:15:43.075 --> 01:15:44.450 align:middle line:84%
The problem with
all these models

01:15:44.450 --> 01:15:46.100 align:middle line:90%
is there's a lot of parameters.

01:15:46.100 --> 01:15:48.530 align:middle line:84%
And so any parameters
that you don't know,

01:15:48.530 --> 01:15:51.020 align:middle line:84%
you can get beautiful profiles,
but all the parameters

01:15:51.020 --> 01:15:52.640 align:middle line:90%
need to be calibrated.

01:15:52.640 --> 01:15:55.380 align:middle line:84%
So that's about all
I have for today.

01:15:55.380 --> 01:15:57.290 align:middle line:84%
And if you're handing
in your homework 3,

01:15:57.290 --> 01:16:01.060 align:middle line:84%
please bring it up
front to this folder.

01:16:01.060 --> 01:16:02.000 align:middle line:90%