PROFESSOR: The confocal
resonator that we've looked at

00:00:24.540 --> 00:00:28.350
has many uses, and we'll
illustrate one of them

00:00:28.350 --> 00:00:30.340
right now.

00:00:30.340 --> 00:00:37.350
So far, the laser frequency
going into the cavity

00:00:37.350 --> 00:00:39.450
was only one frequency.

00:00:39.450 --> 00:00:41.640
We only had one frequency
coming out the laser,

00:00:41.640 --> 00:00:44.820
because we selected it by
means of the polarizer.

00:00:44.820 --> 00:00:49.050
Since the laser oscillates at
several frequencies, at least

00:00:49.050 --> 00:00:52.170
two, at different
polarization, then, again,

00:00:52.170 --> 00:00:58.620
by rotating the polarizer, I can
select the other frequencies.

00:00:58.620 --> 00:01:03.990
So the cavity can be used
as a spectrum analyzer.

00:01:03.990 --> 00:01:09.840
So if we look onto the scope,
as I rotate the polarizer,

00:01:09.840 --> 00:01:12.660
you see that I can bring
in other resonances.

00:01:12.660 --> 00:01:16.470
And these are not associated
with transverse modes

00:01:16.470 --> 00:01:21.028
of the cavity, but they are
associated with the frequencies

00:01:21.028 --> 00:01:21.570
of the laser.

00:01:21.570 --> 00:01:22.470
So here we are.

00:01:22.470 --> 00:01:26.610
Here is when the laser is
operating single frequency

00:01:26.610 --> 00:01:28.260
going into the cavity.

00:01:28.260 --> 00:01:33.990
Now, I rotate the polarizer, and
I admit the other frequencies

00:01:33.990 --> 00:01:37.110
from the laser, which are
different polarizations.

00:01:37.110 --> 00:01:40.860
So in this way, the
confocal resonator

00:01:40.860 --> 00:01:44.460
can be used as a
spectrum analyzer.

00:01:44.460 --> 00:01:48.090
Now, in practice, you have
to be careful in selecting

00:01:48.090 --> 00:01:51.600
the free spectral
range of the resonator

00:01:51.600 --> 00:01:54.240
of the confocal
cavity, so that there's

00:01:54.240 --> 00:01:59.150
no confusion about the
separations in the frequencies

00:01:59.150 --> 00:02:02.200
of the light source.

00:02:02.200 --> 00:02:03.480
So here we are again.

00:02:03.480 --> 00:02:06.000
Here's when the laser
single frequency

00:02:06.000 --> 00:02:09.419
going to the resonator.

00:02:09.419 --> 00:02:11.650
Here we have many frequencies.

00:02:11.650 --> 00:02:14.390
And if we had selected the
free spectral range correctly,

00:02:14.390 --> 00:02:18.120
we would be able to
measure exactly the spacing

00:02:18.120 --> 00:02:20.790
between the modes of the laser.

00:02:23.450 --> 00:02:30.740
So then, in conclusion,
the set of demonstrations,

00:02:30.740 --> 00:02:34.160
we've looked at the
plane parallel cavity,

00:02:34.160 --> 00:02:38.900
we've looked at the
condition under which

00:02:38.900 --> 00:02:41.375
the modes superimpose.

00:02:41.375 --> 00:02:43.520
It was very touchy--
very touchy alignment

00:02:43.520 --> 00:02:45.170
with the plane parallel cavity.

00:02:45.170 --> 00:02:49.220
Then we looked at the
cavity with curved mirrors.

00:02:49.220 --> 00:02:53.000
And we saw lots of
transverse modes

00:02:53.000 --> 00:02:56.960
if we don't have the length
of the resonator adjusted

00:02:56.960 --> 00:02:58.070
suitably.

00:02:58.070 --> 00:03:01.340
We also found that when
the length of the resonator

00:03:01.340 --> 00:03:04.940
was equal to the radius of
curvature of the mirrors

00:03:04.940 --> 00:03:07.220
in this case, the
confocal condition,

00:03:07.220 --> 00:03:11.450
we found that the modes
coalesced into two residences.

00:03:11.450 --> 00:03:17.120
And, finally, we showed
how such a focal resonator

00:03:17.120 --> 00:03:22.280
can be used to analyze the
spectrum of a light source

00:03:22.280 --> 00:03:24.670
like this laser.